Average Armature Voltage of Single Phase Full-Converter Drives Solution

STEP 0: Pre-Calculation Summary
Formula Used
Full Drive Armature Voltage = (2*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi
Va(full) = (2*Vm*cos(α))/pi
This formula uses 1 Constants, 1 Functions, 3 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Full Drive Armature Voltage - (Measured in Volt) - Full Drive Armature Voltage is the average voltage developed at the terminals of the armature of the DC full converter drive.
Peak Input Voltage - (Measured in Volt) - Peak input voltage is the peak value of the sinusoidal input voltage Vmsin(wt) to the converter drive.
Delay Angle of Thyristor - (Measured in Radian) - Delay Angle of Thyristor is the angle at which thyristors are triggered after zero crossing.
STEP 1: Convert Input(s) to Base Unit
Peak Input Voltage: 220 Volt --> 220 Volt No Conversion Required
Delay Angle of Thyristor: 70 Degree --> 1.2217304763958 Radian (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Va(full) = (2*Vm*cos(α))/pi --> (2*220*cos(1.2217304763958))/pi
Evaluating ... ...
Va(full) = 47.9020928736356
STEP 3: Convert Result to Output's Unit
47.9020928736356 Volt --> No Conversion Required
FINAL ANSWER
47.9020928736356 47.90209 Volt <-- Full Drive Armature Voltage
(Calculation completed in 00.004 seconds)

Credits

Created by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has created this Calculator and 50+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

6 Single Phase Drives Calculators

RMS Value of Freewheeling Diode Current in Half Wave Converter Drives
Go RMS Freewheeling Diode Current = Armature Current*sqrt((pi+Delay Angle of Thyristor)/(2*pi))
Average Armature Voltage of Single Phase Half-Wave Converter Drive
Go Half Drive Armature Voltage = Peak Input Voltage/(2*pi)*(1+cos(Delay Angle of Thyristor))
RMS Value of Thyristor Current in Half Wave Converter Drives
Go RMS of Source Current = Armature Current*((pi-Delay Angle of Thyristor)/(2*pi))^(1/2)
Average Armature Voltage of Single Phase Full-Converter Drives
Go Full Drive Armature Voltage = (2*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi
Average Field Voltage of Single Phase Semi-Converter Drives
Go Semi Drive Field Voltage = (Peak Input Voltage/pi)*(1+cos(Delay Angle of Thyristor))
Input Power of Single Phase Full Converter Drives
Go Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor)

Average Armature Voltage of Single Phase Full-Converter Drives Formula

Full Drive Armature Voltage = (2*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi
Va(full) = (2*Vm*cos(α))/pi

What is single phase full-converter drive?

A single phase full-converter drive is a two quadrant drive and is limited to applications up to 15 kW power level. The converter in the field circuit should be a full-wave converter to reverse the polarity of the field current. During regeneration for reversing the direction of power flow, the back emf of the motor is reversed by reversing the field excitation.

What is the difference between a semi-converter and a full-converter?

The main difference between a semi-converter and a full-converter is that the semi-converter always has equal number of diodes and thyristor connected in a bridge structure whereas a full-converter has all the thyristors connected in the bridge structure, and no diodes are present.

How to Calculate Average Armature Voltage of Single Phase Full-Converter Drives?

Average Armature Voltage of Single Phase Full-Converter Drives calculator uses Full Drive Armature Voltage = (2*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi to calculate the Full Drive Armature Voltage, Average Armature Voltage of Single Phase Full-Converter Drives formula is the average voltage developed at the terminals of the armature of the DC motor drive. In the above formula, the delay angle of the armature thyristor (αa) is considered. Full Drive Armature Voltage is denoted by Va(full) symbol.

How to calculate Average Armature Voltage of Single Phase Full-Converter Drives using this online calculator? To use this online calculator for Average Armature Voltage of Single Phase Full-Converter Drives, enter Peak Input Voltage (Vm) & Delay Angle of Thyristor (α) and hit the calculate button. Here is how the Average Armature Voltage of Single Phase Full-Converter Drives calculation can be explained with given input values -> 47.90209 = (2*220*cos(1.2217304763958))/pi.

FAQ

What is Average Armature Voltage of Single Phase Full-Converter Drives?
Average Armature Voltage of Single Phase Full-Converter Drives formula is the average voltage developed at the terminals of the armature of the DC motor drive. In the above formula, the delay angle of the armature thyristor (αa) is considered and is represented as Va(full) = (2*Vm*cos(α))/pi or Full Drive Armature Voltage = (2*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi. Peak input voltage is the peak value of the sinusoidal input voltage Vmsin(wt) to the converter drive & Delay Angle of Thyristor is the angle at which thyristors are triggered after zero crossing.
How to calculate Average Armature Voltage of Single Phase Full-Converter Drives?
Average Armature Voltage of Single Phase Full-Converter Drives formula is the average voltage developed at the terminals of the armature of the DC motor drive. In the above formula, the delay angle of the armature thyristor (αa) is considered is calculated using Full Drive Armature Voltage = (2*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi. To calculate Average Armature Voltage of Single Phase Full-Converter Drives, you need Peak Input Voltage (Vm) & Delay Angle of Thyristor (α). With our tool, you need to enter the respective value for Peak Input Voltage & Delay Angle of Thyristor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!