B Parameter given Voltage 1 (ABCD Parameter) Solution

STEP 0: Pre-Calculation Summary
Formula Used
B Parameter = (-Voltage Port 1+(A Parameter*Voltage Port 2))/Current in Port 2
B = (-V1+(A*V2))/I2
This formula uses 5 Variables
Variables Used
B Parameter - (Measured in Ohm) - B parameter is a generalized line constant. also known as short circuit resistance.
Voltage Port 1 - (Measured in Volt) - Voltage port 1 is the pressure from an electrical circuit's power source that pushes charged electrons (current) through a conducting loop, enabling them to do work such as illuminating a light.
A Parameter - A parameter is a generalized line constant.
Voltage Port 2 - (Measured in Volt) - Voltage port 2 is the pressure from an electrical circuit's power source that pushes charged electrons (current) through a conducting loop, enabling them to do work such as illuminating a light.
Current in Port 2 - (Measured in Ampere) - Current in port 2 is the magnitude of current flowing through port 2.
STEP 1: Convert Input(s) to Base Unit
Voltage Port 1: 440 Volt --> 440 Volt No Conversion Required
A Parameter: 4.6 --> No Conversion Required
Voltage Port 2: 220 Volt --> 220 Volt No Conversion Required
Current in Port 2: 1.02 Ampere --> 1.02 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
B = (-V1+(A*V2))/I2 --> (-440+(4.6*220))/1.02
Evaluating ... ...
B = 560.78431372549
STEP 3: Convert Result to Output's Unit
560.78431372549 Ohm --> No Conversion Required
FINAL ANSWER
560.78431372549 560.7843 Ohm <-- B Parameter
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

19 T-Parameters Calculators

Voltage 2 given Current 1 (ABCD Parameter)
Go Voltage Port 2 = (Current in Port 1+(D Parameter*Current in Port 2))/C Parameter
Current 1 (ABCD Parameter)
Go Current in Port 1 = (C Parameter*Voltage Port 2)-(D Parameter*Current in Port 2)
B Parameter given Voltage 1 (ABCD Parameter)
Go B Parameter = (-Voltage Port 1+(A Parameter*Voltage Port 2))/Current in Port 2
A-Parameter in Terms of Voltage 1 (ABCD Parameter)
Go A Parameter = (Voltage Port 1+(B Parameter*Current in Port 2))/Voltage Port 2
Current 2 given Voltage 1 (ABCD Parameter)
Go Current in Port 2 = ((A Parameter*Voltage Port 2)+Voltage Port 1)/B Parameter
Voltage 1 (ABCD Parameter)
Go Voltage Port 1 = (A Parameter*Voltage Port 2)-(B Parameter*Current in Port 2)
B Inverse Parameter (A'B'C'D'-Parameter)
Go B Inverse Parameter = -Voltage Port 2/Current in Port 1
Voltage-1 given A' Parameter (A'B'C'D'-Parameter)
Go Voltage Port 1 = Voltage Port 2/A Inverse Parameter
A-Inverse Parameter (A'B'C'D'-Parameter)
Go A Inverse Parameter = Voltage Port 2/Voltage Port 1
B Parameter (ABCD Parameter)
Go B Parameter = Voltage Port 1/(-Current in Port 2)
C Parameter (ABCD Parameter)
Go C Parameter = Current in Port 1/Voltage Port 2
Voltage 1 given A Parameter (ABCD Parameter)
Go Voltage Port 1 = A Parameter*Voltage Port 2
A-Parameter (ABCD Parameter)
Go A Parameter = Voltage Port 1/Voltage Port 2
A Parameter In Terms Of T' Parameters
Go A Parameter = D Inverse Parameter/Delta-T'
B Parameter in Terms of G Parameters
Go B Parameter = G22 Parameter/G21 Parameter
C Parameter in Terms of Y Parameters
Go C Parameter = -Delta-Y/Y21 Parameter
B Parameter in Terms of Z Parameters
Go B Parameter = Delta-Z/Z21 Parameter
C Parameter in Terms of Z Parameters
Go C Parameter = 1/Z21 Parameter
A Parameter In Terms Of G Parameters
Go A Parameter = 1/G21 Parameter

B Parameter given Voltage 1 (ABCD Parameter) Formula

B Parameter = (-Voltage Port 1+(A Parameter*Voltage Port 2))/Current in Port 2
B = (-V1+(A*V2))/I2

What are ABCD parameters?

The ABCD-parameters are known variously as chain, cascade, or transmission line parameters. The ABCD constants relate the input current and voltage at port 1 to the output. In Power Systems B and C are Complex numbers A and D are mere constants, the V and I are complex quantities representing V and I Phasors.

How to Calculate B Parameter given Voltage 1 (ABCD Parameter)?

B Parameter given Voltage 1 (ABCD Parameter) calculator uses B Parameter = (-Voltage Port 1+(A Parameter*Voltage Port 2))/Current in Port 2 to calculate the B Parameter, The B Parameter given Voltage 1 (ABCD parameter) formula is defined as the short-circuit transfer impedance of the ABCD Parameter or transmission parameters. B Parameter is denoted by B symbol.

How to calculate B Parameter given Voltage 1 (ABCD Parameter) using this online calculator? To use this online calculator for B Parameter given Voltage 1 (ABCD Parameter), enter Voltage Port 1 (V1), A Parameter (A), Voltage Port 2 (V2) & Current in Port 2 (I2) and hit the calculate button. Here is how the B Parameter given Voltage 1 (ABCD Parameter) calculation can be explained with given input values -> 560.7843 = (-440+(4.6*220))/1.02.

FAQ

What is B Parameter given Voltage 1 (ABCD Parameter)?
The B Parameter given Voltage 1 (ABCD parameter) formula is defined as the short-circuit transfer impedance of the ABCD Parameter or transmission parameters and is represented as B = (-V1+(A*V2))/I2 or B Parameter = (-Voltage Port 1+(A Parameter*Voltage Port 2))/Current in Port 2. Voltage port 1 is the pressure from an electrical circuit's power source that pushes charged electrons (current) through a conducting loop, enabling them to do work such as illuminating a light, A parameter is a generalized line constant, Voltage port 2 is the pressure from an electrical circuit's power source that pushes charged electrons (current) through a conducting loop, enabling them to do work such as illuminating a light & Current in port 2 is the magnitude of current flowing through port 2.
How to calculate B Parameter given Voltage 1 (ABCD Parameter)?
The B Parameter given Voltage 1 (ABCD parameter) formula is defined as the short-circuit transfer impedance of the ABCD Parameter or transmission parameters is calculated using B Parameter = (-Voltage Port 1+(A Parameter*Voltage Port 2))/Current in Port 2. To calculate B Parameter given Voltage 1 (ABCD Parameter), you need Voltage Port 1 (V1), A Parameter (A), Voltage Port 2 (V2) & Current in Port 2 (I2). With our tool, you need to enter the respective value for Voltage Port 1, A Parameter, Voltage Port 2 & Current in Port 2 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate B Parameter?
In this formula, B Parameter uses Voltage Port 1, A Parameter, Voltage Port 2 & Current in Port 2. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • B Parameter = Voltage Port 1/(-Current in Port 2)
  • B Parameter = Delta-Z/Z21 Parameter
  • B Parameter = G22 Parameter/G21 Parameter
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!