Coefficient of Contraction given Coefficient of Discharge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Coefficient of Contraction = Coefficient of Discharge/Coefficient of Velocity
Cc = Cd/Cv
This formula uses 3 Variables
Variables Used
Coefficient of Contraction - The coefficient of Contraction is ratio between the area of the jet at the vena contract and the area of the orifice.
Coefficient of Discharge - Coefficient of Discharge is ratio of Actual discharge to theoretical discharge.
Coefficient of Velocity - The Coefficient of Velocity is the ratio of actual velocity to theoretical velocity.
STEP 1: Convert Input(s) to Base Unit
Coefficient of Discharge: 0.66 --> No Conversion Required
Coefficient of Velocity: 0.92 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Cc = Cd/Cv --> 0.66/0.92
Evaluating ... ...
Cc = 0.717391304347826
STEP 3: Convert Result to Output's Unit
0.717391304347826 --> No Conversion Required
FINAL ANSWER
0.717391304347826 0.717391 <-- Coefficient of Contraction
(Calculation completed in 00.004 seconds)

Credits

Created by Rithik Agrawal
National Institute of Technology Karnataka (NITK), Surathkal
Rithik Agrawal has created this Calculator and 1300+ more calculators!
Verified by Himanshi Sharma
Bhilai Institute of Technology (BIT), Raipur
Himanshi Sharma has verified this Calculator and 800+ more calculators!

11 Orifice Meter Calculators

Actual Velocity at Section 2 given Coefficient of Contraction
Go Actual Velocity = Coefficient of Velocity*sqrt(2*[g]*Venturi Head+(Velocity at Point 2*Coefficient of Contraction*Area of Orifice/Cross Section Area 1)^2)
Discharge through Pipe given Coefficient of Discharge
Go Discharge through Orifice = Coefficient of Discharge*Width of Pipe*(Height of Liquid Bottom Edge-Height of Liquid Top Edge)*(sqrt(2*9.81*Difference in Liquid Level))
Theoretical Velocity at Section 1 in Orifice Meter
Go Velocity at Point 1 = sqrt((Velocity at Point 2^2)-(2*[g]*Venturi Head))
Theoretical Velocity at Section 2 in Orifice Meter
Go Velocity at Point 2 = sqrt(2*[g]*Venturi Head+Velocity at Point 1^2)
Coefficient of Discharge given Coefficient of Contraction
Go Coefficient of Discharge = Coefficient of Velocity*Coefficient of Contraction
Coefficient of Contraction given Coefficient of Discharge
Go Coefficient of Contraction = Coefficient of Discharge/Coefficient of Velocity
Coefficient of Velocity given Coefficient of Discharge
Go Coefficient of Velocity = Coefficient of Discharge/Coefficient of Contraction
Coefficient of Contraction
Go Coefficient of Contraction = Coefficient of Discharge/Coefficient of Velocity
Area of Orifice given Area at Section 2 or at Vena Contracta
Go Area of Orifice = Cross Section Area 2/Coefficient of Contraction
Area at Section 2 or at Vena Contracta
Go Cross Section Area 2 = Coefficient of Contraction*Area of Orifice
Actual Velocity given Theoretical Velocity at Section 2
Go Actual Velocity = Coefficient of Velocity*Velocity at Point 2

Coefficient of Contraction given Coefficient of Discharge Formula

Coefficient of Contraction = Coefficient of Discharge/Coefficient of Velocity
Cc = Cd/Cv

What is Orifice Meter?

An orifice meter is a piece of equipment used to measure the flow rate of a gas or a fluid. It mainly consists of an orifice plate, an orifice plate housing, and a meter tube.

How to Calculate Coefficient of Contraction given Coefficient of Discharge?

Coefficient of Contraction given Coefficient of Discharge calculator uses Coefficient of Contraction = Coefficient of Discharge/Coefficient of Velocity to calculate the Coefficient of Contraction, The Coefficient of Contraction given Coefficient of Discharge is defined as reduction factor for theoretical area through orifice. Coefficient of Contraction is denoted by Cc symbol.

How to calculate Coefficient of Contraction given Coefficient of Discharge using this online calculator? To use this online calculator for Coefficient of Contraction given Coefficient of Discharge, enter Coefficient of Discharge (Cd) & Coefficient of Velocity (Cv) and hit the calculate button. Here is how the Coefficient of Contraction given Coefficient of Discharge calculation can be explained with given input values -> 0.717391 = 0.66/0.92.

FAQ

What is Coefficient of Contraction given Coefficient of Discharge?
The Coefficient of Contraction given Coefficient of Discharge is defined as reduction factor for theoretical area through orifice and is represented as Cc = Cd/Cv or Coefficient of Contraction = Coefficient of Discharge/Coefficient of Velocity. Coefficient of Discharge is ratio of Actual discharge to theoretical discharge & The Coefficient of Velocity is the ratio of actual velocity to theoretical velocity.
How to calculate Coefficient of Contraction given Coefficient of Discharge?
The Coefficient of Contraction given Coefficient of Discharge is defined as reduction factor for theoretical area through orifice is calculated using Coefficient of Contraction = Coefficient of Discharge/Coefficient of Velocity. To calculate Coefficient of Contraction given Coefficient of Discharge, you need Coefficient of Discharge (Cd) & Coefficient of Velocity (Cv). With our tool, you need to enter the respective value for Coefficient of Discharge & Coefficient of Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Coefficient of Contraction?
In this formula, Coefficient of Contraction uses Coefficient of Discharge & Coefficient of Velocity. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Coefficient of Contraction = Coefficient of Discharge/Coefficient of Velocity
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!