Conveyance of Channel given Discharge in Non-Uniform Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Conveyance Function = Discharge/sqrt(Average Energy Slope)
K = Q/sqrt(Sfavg)
This formula uses 1 Functions, 3 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Conveyance Function - Conveyance Function on stage at a section may be determined empirically or by a standard friction law.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material.
Average Energy Slope - Average Energy Slope is at a distance equal to the velocity head above the hydraulic gradient.
STEP 1: Convert Input(s) to Base Unit
Discharge: 3 Cubic Meter per Second --> 3 Cubic Meter per Second No Conversion Required
Average Energy Slope: 1.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K = Q/sqrt(Sfavg) --> 3/sqrt(1.5)
Evaluating ... ...
K = 2.44948974278318
STEP 3: Convert Result to Output's Unit
2.44948974278318 --> No Conversion Required
FINAL ANSWER
2.44948974278318 2.44949 <-- Conveyance Function
(Calculation completed in 00.020 seconds)

Credits

Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

13 Non-Uniform Flow Calculators

Conveyance of Channel at End Sections at 1
Go Conveyance of Channel at End Sections at (1) = (1/Manning’s Roughness Coefficient)*Area of Channel Section 1*Hydraulics Radius of Channel Section 1^(2/3)
Conveyance of Channel at End Sections at 2
Go Conveyance of Channel at End Sections at (2) = (1/Manning’s Roughness Coefficient)*Area of Channel Section 2*Hydraulics Radius of Channel Section 2^(2/3)
Area of Channel with known Conveyance of Channel at Section 1
Go Area of Channel Section 1 = (Conveyance of Channel at End Sections at (1)*Manning’s Roughness Coefficient)/Hydraulics Radius of Channel Section 1^(2/3)
Area of Channel with known Conveyance of Channel at Section 2
Go Area of Channel Section 2 = (Conveyance of Channel at End Sections at (2)*Manning’s Roughness Coefficient)/Hydraulics Radius of Channel Section 2^(2/3)
Average Conveyance of Channel for Non-Uniform Flow
Go Average Conveyance of Channel = sqrt(Conveyance of Channel at End Sections at (1)*Conveyance of Channel at End Sections at (2))
Conveyance of Channel for Non-Uniform Flow for End Sections
Go Conveyance of Channel at End Sections at (1) = Average Conveyance of Channel^2/Conveyance of Channel at End Sections at (2)
Conveyance of Channel for Non-Uniform Flow for End Section
Go Conveyance of Channel at End Sections at (2) = Average Conveyance of Channel^2/Conveyance of Channel at End Sections at (1)
Conveyance of Channel given Discharge in Non-Uniform Flow
Go Conveyance Function = Discharge/sqrt(Average Energy Slope)
Discharge in Non-Uniform Flow by Conveyance Method
Go Discharge = Conveyance Function*sqrt(Average Energy Slope)
Average Energy Slope given Average Conveyance for Non-Uniform Flow
Go Average Energy Slope = Discharge^2/Conveyance Function^2
Length of Reach given Average Energy Slope for Non-Uniform Flow
Go Reach = Frictional Loss/Average Energy Slope
Frictional Loss given Average Energy Slope
Go Frictional Loss = Average Energy Slope*Reach
Average Energy Slope given Frictional Loss
Go Average Energy Slope = Frictional Loss/Reach

Conveyance of Channel given Discharge in Non-Uniform Flow Formula

Conveyance Function = Discharge/sqrt(Average Energy Slope)
K = Q/sqrt(Sfavg)

What is conveyance method of discharge measurement?

A slope-conveyance is one of the simpler methods of computing open channel flow, and it involves applying Manning's equation to a single cross-section.

What is Non-Uniform Flow?

Flow is said to be non-uniform, when there is a change in the velocity of the flow at different points in a flowing fluid, for a given time. For example, the flow of liquids under pressure through long pipelines of varying diameters is referred to as non-uniform flow.

How to Calculate Conveyance of Channel given Discharge in Non-Uniform Flow?

Conveyance of Channel given Discharge in Non-Uniform Flow calculator uses Conveyance Function = Discharge/sqrt(Average Energy Slope) to calculate the Conveyance Function, The Conveyance of Channel given Discharge in Non-Uniform Flow formula is defined as the carrying capacity of a stream cross-section based on its geometry and roughness characteristics alone and is independent of the streambed slope. Conveyance Function is denoted by K symbol.

How to calculate Conveyance of Channel given Discharge in Non-Uniform Flow using this online calculator? To use this online calculator for Conveyance of Channel given Discharge in Non-Uniform Flow, enter Discharge (Q) & Average Energy Slope (Sfavg) and hit the calculate button. Here is how the Conveyance of Channel given Discharge in Non-Uniform Flow calculation can be explained with given input values -> 2.44949 = 3/sqrt(1.5).

FAQ

What is Conveyance of Channel given Discharge in Non-Uniform Flow?
The Conveyance of Channel given Discharge in Non-Uniform Flow formula is defined as the carrying capacity of a stream cross-section based on its geometry and roughness characteristics alone and is independent of the streambed slope and is represented as K = Q/sqrt(Sfavg) or Conveyance Function = Discharge/sqrt(Average Energy Slope). Discharge is the volumetric flow rate of water that is transported through a given cross-sectional area. It includes any suspended solids, dissolved chemicals, or biologic material & Average Energy Slope is at a distance equal to the velocity head above the hydraulic gradient.
How to calculate Conveyance of Channel given Discharge in Non-Uniform Flow?
The Conveyance of Channel given Discharge in Non-Uniform Flow formula is defined as the carrying capacity of a stream cross-section based on its geometry and roughness characteristics alone and is independent of the streambed slope is calculated using Conveyance Function = Discharge/sqrt(Average Energy Slope). To calculate Conveyance of Channel given Discharge in Non-Uniform Flow, you need Discharge (Q) & Average Energy Slope (Sfavg). With our tool, you need to enter the respective value for Discharge & Average Energy Slope and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!