Correction Factor when Oxygen Transfer Capacity Solution

STEP 0: Pre-Calculation Summary
Formula Used
Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*(1.024)^(Temperature-20))/(9.17))
f = N/((Ns*(DS-DL)*(1.024)^(T-20))/(9.17))
This formula uses 6 Variables
Variables Used
Correction Factor - Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred under field condition.
Oxygen transfer capacity - (Measured in Kilogram per Second per Watt) - Oxygen transfer capacity under standard conditions.
Dissolved oxygen saturation - (Measured in Kilogram per Cubic Meter) - Dissolved oxygen saturation value for sewage at operating temperature.
Operation dissolved oxygen - (Measured in Kilogram per Cubic Meter) - Operation dissolved oxygen level in aeration tank.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Oxygen Transferred: 3 Kilogram per Hour per Kilowatt --> 8.33333333333333E-07 Kilogram per Second per Watt (Check conversion here)
Oxygen transfer capacity: 2 Kilogram per Hour per Kilowatt --> 5.55555555555556E-07 Kilogram per Second per Watt (Check conversion here)
Dissolved oxygen saturation: 3 Milligram per Liter --> 0.003 Kilogram per Cubic Meter (Check conversion here)
Operation dissolved oxygen: 2 Milligram per Liter --> 0.002 Kilogram per Cubic Meter (Check conversion here)
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
f = N/((Ns*(DS-DL)*(1.024)^(T-20))/(9.17)) --> 8.33333333333333E-07/((5.55555555555556E-07*(0.003-0.002)*(1.024)^(85-20))/(9.17))
Evaluating ... ...
f = 2944.17359332134
STEP 3: Convert Result to Output's Unit
2944.17359332134 --> No Conversion Required
FINAL ANSWER
2944.17359332134 2944.174 <-- Correction Factor
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

9 Oxygen Transfer Capacity Calculators

Oxygen Transfer Capacity under Standard Conditions
Go Oxygen transfer capacity = Oxygen Transferred/(((Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Correction Factor when Oxygen Transfer Capacity
Go Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field Conditions
Go Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17)
Oxygen transfer capacity given difference between saturation and operation dissolved oxygen
Go Oxygen transfer capacity = Oxygen Transferred/((Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen
Go Oxygen Transferred = (Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)
Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.85
Go Oxygen transfer capacity = Oxygen Transferred/(((Dissolved oxygen saturation-Operation dissolved oxygen)*0.85*(1.024)^(Temperature-20))/(9.17))
Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8
Go Oxygen transfer capacity = Oxygen Transferred/(((Dissolved oxygen saturation-Operation dissolved oxygen)*0.8*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field Conditions when Correction Factor is 0.85
Go Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.85*(1.024)^(Temperature-20))/(9.17)
Oxygen Transferred under Field Conditions when Correction Factor is 0.8
Go Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.8*(1.024)^(Temperature-20))/(9.17)

Correction Factor when Oxygen Transfer Capacity Formula

Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*(1.024)^(Temperature-20))/(9.17))
f = N/((Ns*(DS-DL)*(1.024)^(T-20))/(9.17))

What is aeration tank ?

Aeration in an activated sludge process is based on pumping air into a tank, which promotes the microbial growth in the wastewater. The microbes feed on the organic material, forming flocks which can easily settle out.

How to Calculate Correction Factor when Oxygen Transfer Capacity?

Correction Factor when Oxygen Transfer Capacity calculator uses Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*(1.024)^(Temperature-20))/(9.17)) to calculate the Correction Factor, The Correction Factor when Oxygen Transfer Capacity calculates the correction factor when we have prior information of other parameters used. Correction Factor is denoted by f symbol.

How to calculate Correction Factor when Oxygen Transfer Capacity using this online calculator? To use this online calculator for Correction Factor when Oxygen Transfer Capacity, enter Oxygen Transferred (N), Oxygen transfer capacity (Ns), Dissolved oxygen saturation (DS), Operation dissolved oxygen (DL) & Temperature (T) and hit the calculate button. Here is how the Correction Factor when Oxygen Transfer Capacity calculation can be explained with given input values -> 2944.174 = 8.33333333333333E-07/((5.55555555555556E-07*(0.003-0.002)*(1.024)^(85-20))/(9.17)).

FAQ

What is Correction Factor when Oxygen Transfer Capacity?
The Correction Factor when Oxygen Transfer Capacity calculates the correction factor when we have prior information of other parameters used and is represented as f = N/((Ns*(DS-DL)*(1.024)^(T-20))/(9.17)) or Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*(1.024)^(Temperature-20))/(9.17)). Oxygen Transferred under field condition, Oxygen transfer capacity under standard conditions, Dissolved oxygen saturation value for sewage at operating temperature, Operation dissolved oxygen level in aeration tank & Temperature is the degree or intensity of heat present in a substance or object.
How to calculate Correction Factor when Oxygen Transfer Capacity?
The Correction Factor when Oxygen Transfer Capacity calculates the correction factor when we have prior information of other parameters used is calculated using Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*(1.024)^(Temperature-20))/(9.17)). To calculate Correction Factor when Oxygen Transfer Capacity, you need Oxygen Transferred (N), Oxygen transfer capacity (Ns), Dissolved oxygen saturation (DS), Operation dissolved oxygen (DL) & Temperature (T). With our tool, you need to enter the respective value for Oxygen Transferred, Oxygen transfer capacity, Dissolved oxygen saturation, Operation dissolved oxygen & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!