Current on Operation with Differential Input Voltage Solution

STEP 0: Pre-Calculation Summary
Formula Used
Total Current = 1/2*(Process Transconductance Parameter*Aspect Ratio)*(Voltage across Diode-Threshold Voltage)^2
It = 1/2*(k'n*WL)*(Vd-Vt)^2
This formula uses 5 Variables
Variables Used
Total Current - (Measured in Ampere) - Total current is the total or modulated current of an AM modulator.
Process Transconductance Parameter - (Measured in Siemens) - Process transconductance parameter is the product of mobility of electrons in channel and oxide capacitance.
Aspect Ratio - Aspect Ratio is the ratio of the width of the channel to the length of the channel.
Voltage across Diode - (Measured in Volt) - Voltage across Diode is the voltage applied across the terminals of the diode.
Threshold Voltage - (Measured in Volt) - Threshold voltage of transistor is the minimum gate to source voltage that is needed to create a conducting path between the source and drain terminals.
STEP 1: Convert Input(s) to Base Unit
Process Transconductance Parameter: 0.02 Millisiemens --> 2E-05 Siemens (Check conversion here)
Aspect Ratio: 5 --> No Conversion Required
Voltage across Diode: 23.049 Volt --> 23.049 Volt No Conversion Required
Threshold Voltage: 19.5 Volt --> 19.5 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
It = 1/2*(k'n*WL)*(Vd-Vt)^2 --> 1/2*(2E-05*5)*(23.049-19.5)^2
Evaluating ... ...
It = 0.00062977005
STEP 3: Convert Result to Output's Unit
0.00062977005 Ampere -->0.62977005 Milliampere (Check conversion here)
FINAL ANSWER
0.62977005 0.62977 Milliampere <-- Total Current
(Calculation completed in 00.004 seconds)

Credits

Created by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has created this Calculator and 600+ more calculators!
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

4 DC Offset Calculators

Current on Operation with Differential Input Voltage
Go Total Current = 1/2*(Process Transconductance Parameter*Aspect Ratio)*(Voltage across Diode-Threshold Voltage)^2
Output Voltage of Voltage Amplifier
Go Output Voltage = Source Voltage-(Drain Current*Load Resistance)
Offset Voltage of MOSFET with Current-Mirror Load
Go Input Offset Voltage = -(2*Threshold Voltage)/Forced Common-Emitter Current Gain
Maximum Differential Input Voltage of MOSFET given Overdrive Voltage
Go Differential Input Signal = sqrt(2)*Effective Voltage

Current on Operation with Differential Input Voltage Formula

Total Current = 1/2*(Process Transconductance Parameter*Aspect Ratio)*(Voltage across Diode-Threshold Voltage)^2
It = 1/2*(k'n*WL)*(Vd-Vt)^2

What is differential input voltage?

The differential input voltage is the maximum voltage that can be supplied to the +Input (Non-inverting input) and -Input (Inverting input) pins without causing damage or degrading IC characteristics.

How to Calculate Current on Operation with Differential Input Voltage?

Current on Operation with Differential Input Voltage calculator uses Total Current = 1/2*(Process Transconductance Parameter*Aspect Ratio)*(Voltage across Diode-Threshold Voltage)^2 to calculate the Total Current, The Current on operation with differential input voltage formula is defined as the flow of electric charge across a surface at the rate of one coulomb per second. Total Current is denoted by It symbol.

How to calculate Current on Operation with Differential Input Voltage using this online calculator? To use this online calculator for Current on Operation with Differential Input Voltage, enter Process Transconductance Parameter (k'n), Aspect Ratio (WL), Voltage across Diode (Vd) & Threshold Voltage (Vt) and hit the calculate button. Here is how the Current on Operation with Differential Input Voltage calculation can be explained with given input values -> 9006.162 = 1/2*(2E-05*5)*(23.049-19.5)^2.

FAQ

What is Current on Operation with Differential Input Voltage?
The Current on operation with differential input voltage formula is defined as the flow of electric charge across a surface at the rate of one coulomb per second and is represented as It = 1/2*(k'n*WL)*(Vd-Vt)^2 or Total Current = 1/2*(Process Transconductance Parameter*Aspect Ratio)*(Voltage across Diode-Threshold Voltage)^2. Process transconductance parameter is the product of mobility of electrons in channel and oxide capacitance, Aspect Ratio is the ratio of the width of the channel to the length of the channel, Voltage across Diode is the voltage applied across the terminals of the diode & Threshold voltage of transistor is the minimum gate to source voltage that is needed to create a conducting path between the source and drain terminals.
How to calculate Current on Operation with Differential Input Voltage?
The Current on operation with differential input voltage formula is defined as the flow of electric charge across a surface at the rate of one coulomb per second is calculated using Total Current = 1/2*(Process Transconductance Parameter*Aspect Ratio)*(Voltage across Diode-Threshold Voltage)^2. To calculate Current on Operation with Differential Input Voltage, you need Process Transconductance Parameter (k'n), Aspect Ratio (WL), Voltage across Diode (Vd) & Threshold Voltage (Vt). With our tool, you need to enter the respective value for Process Transconductance Parameter, Aspect Ratio, Voltage across Diode & Threshold Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!