Drawdown given Specific Capacity of Well Solution

STEP 0: Pre-Calculation Summary
Formula Used
Total Drawdown in Well = Discharge/Specific Capacity
st = Q/Sc
This formula uses 3 Variables
Variables Used
Total Drawdown in Well - (Measured in Meter) - The Total Drawdown in Well is defined as the reduction in hydraulic head observed at a well in an aquifer, typically due to pumping a well as part of an aquifer test or well test.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Specific Capacity - (Measured in Square Meter per Second) - Specific Capacity is the quantity that which a water well can produce per unit of drawdown.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Specific Capacity: 0.037 Square Meter per Second --> 0.037 Square Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
st = Q/Sc --> 1.01/0.037
Evaluating ... ...
st = 27.2972972972973
STEP 3: Convert Result to Output's Unit
27.2972972972973 Meter --> No Conversion Required
FINAL ANSWER
27.2972972972973 27.2973 Meter <-- Total Drawdown in Well
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

7 Specific Capacity of Well Calculators

Aquifer Loss Coefficient given Specific Capacity
Go Aquifer Loss Coefficient = ((Discharge/Specific Capacity)-Head Loss in well)/Discharge
Specific Capacity given Aquifer Loss
Go Specific Capacity = (Discharge/(Head Loss in well+Aquifer loss))
Well Discharge given Specific Capacity
Go Discharge = Specific Capacity*(Head Loss in well+Aquifer loss)
Aquifer Loss given Specific Capacity
Go Aquifer loss = (Discharge/Specific Capacity)-Head Loss in well
Drawdown given Specific Capacity of Well
Go Total Drawdown in Well = Discharge/Specific Capacity
Discharge given Specific Capacity
Go Discharge = Specific Capacity*Total Drawdown in Well
Specific Capacity given Drawdown
Go Specific Capacity = Discharge/Total Drawdown in Well

Drawdown given Specific Capacity of Well Formula

Total Drawdown in Well = Discharge/Specific Capacity
st = Q/Sc

What is Drawdown?

A drawdown is a peak-to-trough decline during a specific period for an investment, trading account, or fund. A drawdown is usually quoted as the percentage between the peak and the subsequent trough.

How to Calculate Drawdown given Specific Capacity of Well?

Drawdown given Specific Capacity of Well calculator uses Total Drawdown in Well = Discharge/Specific Capacity to calculate the Total Drawdown in Well, The Drawdown given Specific Capacity of Well is defined as the value of drawdown when we have prior information of other parameters used. Total Drawdown in Well is denoted by st symbol.

How to calculate Drawdown given Specific Capacity of Well using this online calculator? To use this online calculator for Drawdown given Specific Capacity of Well, enter Discharge (Q) & Specific Capacity (Sc) and hit the calculate button. Here is how the Drawdown given Specific Capacity of Well calculation can be explained with given input values -> 27.2973 = 1.01/0.037.

FAQ

What is Drawdown given Specific Capacity of Well?
The Drawdown given Specific Capacity of Well is defined as the value of drawdown when we have prior information of other parameters used and is represented as st = Q/Sc or Total Drawdown in Well = Discharge/Specific Capacity. Discharge is the rate of flow of a liquid & Specific Capacity is the quantity that which a water well can produce per unit of drawdown.
How to calculate Drawdown given Specific Capacity of Well?
The Drawdown given Specific Capacity of Well is defined as the value of drawdown when we have prior information of other parameters used is calculated using Total Drawdown in Well = Discharge/Specific Capacity. To calculate Drawdown given Specific Capacity of Well, you need Discharge (Q) & Specific Capacity (Sc). With our tool, you need to enter the respective value for Discharge & Specific Capacity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!