Flow Rate given Retention Volume and Time Solution

STEP 0: Pre-Calculation Summary
Formula Used
Flow Rate given RT and RV = (Retention Volume/Retention Time)
FR = (VR/tr)
This formula uses 3 Variables
Variables Used
Flow Rate given RT and RV - (Measured in Cubic Meter per Second) - Flow Rate given RT and RV is the volume of solute traveled per unit of time.
Retention Volume - (Measured in Cubic Meter) - The Retention Volume is defined as the volume of the mobile phase required to elute the solute from the column.
Retention Time - (Measured in Second) - The Retention Time of solute is defined as the time taken by the solute to move over the stationary phase and to come out of the column.
STEP 1: Convert Input(s) to Base Unit
Retention Volume: 11.2 Liter --> 0.0112 Cubic Meter (Check conversion here)
Retention Time: 13 Second --> 13 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
FR = (VR/tr) --> (0.0112/13)
Evaluating ... ...
FR = 0.000861538461538462
STEP 3: Convert Result to Output's Unit
0.000861538461538462 Cubic Meter per Second -->0.861538461538462 Liter per Second (Check conversion here)
FINAL ANSWER
0.861538461538462 0.861538 Liter per Second <-- Flow Rate given RT and RV
(Calculation completed in 00.020 seconds)

Credits

Created by Prashant Singh
K J Somaiya College of science (K J Somaiya), Mumbai
Prashant Singh has created this Calculator and 700+ more calculators!
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

7 Retention Volume Calculators

Retention Volume given Capacity Factor
Go Retention Volume given CF = (Capacity Factor+1)*Unretained Mobile Phase Volume
Retention Volume given Flow Rate
Go Retention Volume given Flow Rate = (Retention Time*Flow Rate of Mobile Phase)
Half of Average Width of Peaks given Resolution and Change in Retention Volume
Go Half of Average Width of Peak = (0.589*Change in Retention Time)/Resolution
Average Width of Peak given Resolution and Change in Retention Volume
Go Average Width of Peaks given RV = (Change in retention volume/Resolution)
Flow Rate given Retention Volume and Time
Go Flow Rate given RT and RV = (Retention Volume/Retention Time)
Unretained Volume given Capacity Factor
Go Unretained Volume = (Retention Volume)/(Capacity Factor+1)
Retention Factor
Go Actual Retention Factor = Solute Distance/Solvent Distance

Flow Rate given Retention Volume and Time Formula

Flow Rate given RT and RV = (Retention Volume/Retention Time)
FR = (VR/tr)

What is Chromatography?

A separation process based on the various partitioning coefficients of different solutes between the two phases.
Involving the interaction of solute(s) and two phases
Mobile phase: A gas or liquid that moves through the column.
Stationary phase: A solid or liquid that remains in place.

What are the types of Chromatography?

1) Adsorption chromatography
2) Ion-exchange chromatography
3) Partition chromatography
4) Molecular Size exclusion chromatography
5) Affinity chromatography

How to Calculate Flow Rate given Retention Volume and Time?

Flow Rate given Retention Volume and Time calculator uses Flow Rate given RT and RV = (Retention Volume/Retention Time) to calculate the Flow Rate given RT and RV, The Flow Rate given Retention Volume and Time formula is defined as the ratio of the volume of solute retained to the retention time of the solute. Flow Rate given RT and RV is denoted by FR symbol.

How to calculate Flow Rate given Retention Volume and Time using this online calculator? To use this online calculator for Flow Rate given Retention Volume and Time, enter Retention Volume (VR) & Retention Time (tr) and hit the calculate button. Here is how the Flow Rate given Retention Volume and Time calculation can be explained with given input values -> 861.5385 = (0.0112/13).

FAQ

What is Flow Rate given Retention Volume and Time?
The Flow Rate given Retention Volume and Time formula is defined as the ratio of the volume of solute retained to the retention time of the solute and is represented as FR = (VR/tr) or Flow Rate given RT and RV = (Retention Volume/Retention Time). The Retention Volume is defined as the volume of the mobile phase required to elute the solute from the column & The Retention Time of solute is defined as the time taken by the solute to move over the stationary phase and to come out of the column.
How to calculate Flow Rate given Retention Volume and Time?
The Flow Rate given Retention Volume and Time formula is defined as the ratio of the volume of solute retained to the retention time of the solute is calculated using Flow Rate given RT and RV = (Retention Volume/Retention Time). To calculate Flow Rate given Retention Volume and Time, you need Retention Volume (VR) & Retention Time (tr). With our tool, you need to enter the respective value for Retention Volume & Retention Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.