Flow rate of electrolyte Solution

STEP 0: Pre-Calculation Summary
Formula Used
Flow Rate of the Electrolyte = (pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole))
Q = (pi*(P1-Patm)*h^3)/(6*μv*ln(R0/R1))
This formula uses 1 Constants, 1 Functions, 7 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
ln - The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function., ln(Number)
Variables Used
Flow Rate of the Electrolyte - (Measured in Cubic Meter per Second) - Flow rate of the electrolyte is the flow rate of the electrolyte used in EDM.
Pressure in Flushing Hole - (Measured in Pascal) - Pressure in Flushing Hole is the pressure in hole during EDM machining.
Atmospheric Pressure - (Measured in Pascal) - Atmospheric pressure, also known as barometric pressure, is the pressure within the atmosphere of Earth.
Gap Spacing - (Measured in Meter) - Gap spacing is the width of distance between electrode and work during EDM.
Dynamic Viscosity - (Measured in Pascal Second) - The Dynamic Viscosity of a fluid is the measure of its resistance to flow when an external force is applied.
Radius of the Electrodes - (Measured in Meter) - Radius of the electrodes is defined as the radius of the electrode used for unconventional machining by EDM.
Radius of Flushing Hole - (Measured in Meter) - Radius of flushing hole is the radius of flushing hole in EDM.
STEP 1: Convert Input(s) to Base Unit
Pressure in Flushing Hole: 11 Newton per Square Centimeter --> 110000 Pascal (Check conversion here)
Atmospheric Pressure: 10 Newton per Square Centimeter --> 100000 Pascal (Check conversion here)
Gap Spacing: 2 Centimeter --> 0.02 Meter (Check conversion here)
Dynamic Viscosity: 10.2 Poise --> 1.02 Pascal Second (Check conversion here)
Radius of the Electrodes: 5 Centimeter --> 0.05 Meter (Check conversion here)
Radius of Flushing Hole: 4 Centimeter --> 0.04 Meter (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Q = (pi*(P1-Patm)*h^3)/(6*μv*ln(R0/R1)) --> (pi*(110000-100000)*0.02^3)/(6*1.02*ln(0.05/0.04))
Evaluating ... ...
Q = 0.184036555810365
STEP 3: Convert Result to Output's Unit
0.184036555810365 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
0.184036555810365 0.184037 Cubic Meter per Second <-- Flow Rate of the Electrolyte
(Calculation completed in 00.004 seconds)

Credits

Created by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has created this Calculator and 400+ more calculators!
Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology (VNRVJIET), Hyderabad
Sai Venkata Phanindra Chary Arendra has verified this Calculator and 300+ more calculators!

7 Flow rate of the electrolyte Calculators

Gap spacing
Go Gap Spacing = ((Flow Rate of the Electrolyte*(6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole)))/(pi*(Pressure in Flushing Hole-Atmospheric Pressure)))^(1/3)
Radius of flushing hole
Go Radius of Flushing Hole = Radius of the Electrodes/exp((pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(Flow Rate of the Electrolyte*6*Dynamic Viscosity))
Radius of electrode
Go Radius of the Electrodes = Radius of Flushing Hole*exp((pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(Flow Rate of the Electrolyte*6*Dynamic Viscosity))
Pressure in flushing hole flow rate electrolyte
Go Pressure in Flushing Hole = Atmospheric Pressure+((Flow Rate of the Electrolyte*6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole))/(pi*Gap Spacing^3))
Dynamic viscosity of electrolyte
Go Dynamic Viscosity = (pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(6*Flow Rate of the Electrolyte*ln(Radius of the Electrodes/Radius of Flushing Hole))
Flow rate of electrolyte
Go Flow Rate of the Electrolyte = (pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole))
Atmospheric pressure
Go Atmospheric Pressure = Pressure in Flushing Hole-((Flow Rate of the Electrolyte*6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole))/(pi*Gap Spacing^3))

Flow rate of electrolyte Formula

Flow Rate of the Electrolyte = (pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole))
Q = (pi*(P1-Patm)*h^3)/(6*μv*ln(R0/R1))

What does the term Flushing means in Electric Discharge Machining?

Flushing refers to the method in which the dielectric fluid flows between the tool and the work gap.The efficiency of machining depends to a greater extent on the efficiency of the flushing. The wear debris present in the spark gap should be removed as quickly as possible. With poor flushing there is a possibility of build-up of the machined particles in the gap resulting in the short-circuiting and lower material removal rates. Problems with improper flushing are: uneven and significant tool wear affecting accuracy and surface finish; reduced removal rates due to unstable machining conditions and arcing around regions with high concentration of debris. It is noted during an experimental study that there is an optimum dielectric flushing rate of about 13 ml/s while machining AISI O1 tool steel, where the crack density and average thickness of the recast layer are at a minimum.

How to Calculate Flow rate of electrolyte?

Flow rate of electrolyte calculator uses Flow Rate of the Electrolyte = (pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole)) to calculate the Flow Rate of the Electrolyte, The Flow rate of electrolyte formula is defined as volume of electrolyte pumped to flushing hole per unit of time. Flow Rate of the Electrolyte is denoted by Q symbol.

How to calculate Flow rate of electrolyte using this online calculator? To use this online calculator for Flow rate of electrolyte, enter Pressure in Flushing Hole (P1), Atmospheric Pressure (Patm), Gap Spacing (h), Dynamic Viscosity v), Radius of the Electrodes (R0) & Radius of Flushing Hole (R1) and hit the calculate button. Here is how the Flow rate of electrolyte calculation can be explained with given input values -> 0.184037 = (pi*(110000-100000)*0.02^3)/(6*1.02*ln(0.05/0.04)).

FAQ

What is Flow rate of electrolyte?
The Flow rate of electrolyte formula is defined as volume of electrolyte pumped to flushing hole per unit of time and is represented as Q = (pi*(P1-Patm)*h^3)/(6*μv*ln(R0/R1)) or Flow Rate of the Electrolyte = (pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole)). Pressure in Flushing Hole is the pressure in hole during EDM machining, Atmospheric pressure, also known as barometric pressure, is the pressure within the atmosphere of Earth, Gap spacing is the width of distance between electrode and work during EDM, The Dynamic Viscosity of a fluid is the measure of its resistance to flow when an external force is applied, Radius of the electrodes is defined as the radius of the electrode used for unconventional machining by EDM & Radius of flushing hole is the radius of flushing hole in EDM.
How to calculate Flow rate of electrolyte?
The Flow rate of electrolyte formula is defined as volume of electrolyte pumped to flushing hole per unit of time is calculated using Flow Rate of the Electrolyte = (pi*(Pressure in Flushing Hole-Atmospheric Pressure)*Gap Spacing^3)/(6*Dynamic Viscosity*ln(Radius of the Electrodes/Radius of Flushing Hole)). To calculate Flow rate of electrolyte, you need Pressure in Flushing Hole (P1), Atmospheric Pressure (Patm), Gap Spacing (h), Dynamic Viscosity v), Radius of the Electrodes (R0) & Radius of Flushing Hole (R1). With our tool, you need to enter the respective value for Pressure in Flushing Hole, Atmospheric Pressure, Gap Spacing, Dynamic Viscosity, Radius of the Electrodes & Radius of Flushing Hole and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!