Gas phase mass transfer coefficient given humidity Solution

STEP 0: Pre-Calculation Summary
Formula Used
Gas Phase Mass Transfer Coefficient = (Mass Velocity of Air/Height)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit))
ky = (G/Z)*ln((Yi-Y1)/(Yi-Y2))
This formula uses 1 Functions, 6 Variables
Functions Used
ln - The natural logarithm, also known as the logarithm to the base e, is the inverse function of the natural exponential function., ln(Number)
Variables Used
Gas Phase Mass Transfer Coefficient - (Measured in Mole per Second Square Meter) - Gas phase mass transfer coefficient is a diffusion rate constant that relates the mass transfer rate, mass transfer area, and concentration change as driving force.
Mass Velocity of Air - Mass velocity of air is the amount of air travelling per unit area in a second.
Height - (Measured in Meter) - Height of the tower is the total length of the tower from the top to the bottom.
Absolute Humidity at Final Temperature - Absolute humidity at final temperature is the quality of water vapor in the wet air of unit volume at the final equilibrium air temperature.
Humidity of air at entry - The humidity of air at entry is the quantity of water vapor at wet air in the entrance of the tower.
Humidity of air at exit - Humidity of air at exit is the quantity of water vapor at wet air in the exit of the tower.
STEP 1: Convert Input(s) to Base Unit
Mass Velocity of Air: 18 --> No Conversion Required
Height: 0.05 Meter --> 0.05 Meter No Conversion Required
Absolute Humidity at Final Temperature: 60 --> No Conversion Required
Humidity of air at entry: 5 --> No Conversion Required
Humidity of air at exit: 15 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ky = (G/Z)*ln((Yi-Y1)/(Yi-Y2)) --> (18/0.05)*ln((60-5)/(60-15))
Evaluating ... ...
ky = 72.2414503663745
STEP 3: Convert Result to Output's Unit
72.2414503663745 Mole per Second Square Meter --> No Conversion Required
FINAL ANSWER
72.2414503663745 72.24145 Mole per Second Square Meter <-- Gas Phase Mass Transfer Coefficient
(Calculation completed in 00.004 seconds)

Credits

Created by Nishan Poojary
Shri Madhwa Vadiraja Institute of Technology and Management (SMVITM), Udupi
Nishan Poojary has created this Calculator and 500+ more calculators!
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

24 Humidification Calculators

Absolute humidity at inside temperature in dehumidification
Go Absolute Humidity (ti) = Absolute Humidity of Air(tg)-(((Liquid Phase Heat Transfer Coefficient*(Temperature at inner surface-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Temperature at inner surface))/(Gas Phase Mass Transfer Coefficient*Enthalpy of Evaporation))
Enthalpy of evaporation in dehumidification
Go Enthalpy of Evaporation = ((Liquid Phase Heat Transfer Coefficient*(Temperature at inner surface-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Temperature at inner surface))/(Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))
Liquid phase heat transfer coefficient in dehumidification
Go Liquid Phase Heat Transfer Coefficient = ((Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Temperature at inner surface))+Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))/(Temperature at inner surface-Liquid layer temperature)
Gas phase heat transfer coefficient in dehumidification
Go Gas Phase Heat Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-(Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti))))/(Bulk Gas Temperature-Inside Temperature)
Gas phase mass transfer coefficient in dehumidification
Go Gas Phase Mass Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Enthalpy of Evaporation*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))
Bulk gas temperature in dehumidification
Go Bulk Gas Temperature = (((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-(Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti))))/Gas Phase Heat Transfer Coefficient)+Inside Temperature
Liquid layer temperature in dehumidification
Go Liquid layer temperature = Inside Temperature-(((Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))+Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))/Liquid Phase Heat Transfer Coefficient)
Specific heat of air given gas constant
Go Specific Heat of Air = (((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*(Air Temperature-Wet Bulb Temperature)*Mean Temperature*(Lewis Number^0.67))))
Gas constant of water vapor
Go Gas constant = (((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/((Air Temperature-Wet Bulb Temperature)*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67))))
Temperature of air given gas constant of water
Go Air Temperature = (((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67))))+Wet Bulb Temperature
Wet bulb temperature given gas constant of water vapor
Go Wet Bulb Temperature = Air Temperature-((Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))/(Gas constant*Density*Specific Heat of Air*Mean Temperature*(Lewis Number^0.67)))
Temperature of air during humidification
Go Air Temperature = (((0.622*Enthalpy of Evaporation)/(Specific Heat of Air*(Lewis Number^0.67)))*((Partial Pressure/Total Pressure)-(Partial Pressure in air/Total Pressure)))+Wet Bulb Temperature
Wet bulb temperature of humidification
Go Wet Bulb Temperature = Air Temperature-((0.622*Enthalpy of Evaporation)/(Specific Heat of Air*(Lewis Number^0.67)))*((Partial Pressure/Total Pressure)-(Partial Pressure in air/Total Pressure))
Absolute Humidity of Air at Final Equilibrium Air Temperature
Go Absolute Humidity of Air(ta) = (((Specific Heat of Air+(Absolute Humidity of Air(tg)*Specific Heat of Water Vapor))*(Bulk Gas Temperature-Temperature))/(Enthalpy of Evaporation))+Absolute Humidity of Air(tg)
Gas phase mass transfer coefficient given humidity
Go Gas Phase Mass Transfer Coefficient = (Mass Velocity of Air/Height)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit))
Height of tower in adiabatic humidification
Go Height = (Mass Velocity of Air/Gas Phase Mass Transfer Coefficient)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit))
Mass velocity of air per unit area
Go Mass Velocity of Air = (Height*Gas Phase Mass Transfer Coefficient)/ln((Absolute Humidity of Air(ta)-Humidity of Air at Entry(t))/(Absolute Humidity of Air(ta)-Humidity of air at exit))
Partial pressure of water vapor at wet bulb temperature
Go Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air
Convective mass transfer coefficient in humidification
Go Convective Mass Transfer Coefficient = (Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))
Enthalpy of evaporation for water in humidification
Go Enthalpy of Evaporation = (Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Convective Mass Transfer Coefficient*(Partial Pressure-Partial Pressure in air))
Partial pressure of water vapor in air
Go Partial Pressure in air = Partial Pressure-((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))
Heat transfer coefficient in humidification
Go Heat Transfer Coefficient = ((Partial Pressure-Partial Pressure in air)*(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))/(Air Temperature-Wet Bulb Temperature)
Enthalpy of evaporation of water in humidification
Go Enthalpy of Evaporation = (Specific Heat of Air*(Lewis Number^0.67))/((Absolute Humidity of Air(tw)-Absolute Humidity of Air(atm))/(Air Temperature-Wet Bulb Temperature))
Specific heat of air during humidification
Go Specific Heat of Air = (Absolute Humidity of Air(tw)-Absolute Humidity of Air(atm))*Enthalpy of Evaporation/((Temperature-Air Temperature)*Lewis Number^0.67)

Gas phase mass transfer coefficient given humidity Formula

Gas Phase Mass Transfer Coefficient = (Mass Velocity of Air/Height)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit))
ky = (G/Z)*ln((Yi-Y1)/(Yi-Y2))

What is humidification?

Humidification is the process in which the moisture or water vapor or humidity is added to the air. Common equipment used in this process is a humidifier. Dehumidification as the term suggests, is the opposite of humidification since dehumidification means removing the moisture from the air. Common equipment used in this process is a dehumidifier.
Humidity is the presence of water vapor or moisture in the air, while relative humidity, on the other hand, is the comparison of the actual moisture or water vapor in the air vs. the total water vapor or moisture that the air can handle.

How to Calculate Gas phase mass transfer coefficient given humidity?

Gas phase mass transfer coefficient given humidity calculator uses Gas Phase Mass Transfer Coefficient = (Mass Velocity of Air/Height)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit)) to calculate the Gas Phase Mass Transfer Coefficient, The Gas phase mass transfer coefficient given humidity formula is defined as the diffusivity of the gas phase to the boundary layer thickness. Gas Phase Mass Transfer Coefficient is denoted by ky symbol.

How to calculate Gas phase mass transfer coefficient given humidity using this online calculator? To use this online calculator for Gas phase mass transfer coefficient given humidity, enter Mass Velocity of Air (G), Height (Z), Absolute Humidity at Final Temperature (Yi), Humidity of air at entry (Y1) & Humidity of air at exit (Y2) and hit the calculate button. Here is how the Gas phase mass transfer coefficient given humidity calculation can be explained with given input values -> 72.24145 = (18/0.05)*ln((60-5)/(60-15)).

FAQ

What is Gas phase mass transfer coefficient given humidity?
The Gas phase mass transfer coefficient given humidity formula is defined as the diffusivity of the gas phase to the boundary layer thickness and is represented as ky = (G/Z)*ln((Yi-Y1)/(Yi-Y2)) or Gas Phase Mass Transfer Coefficient = (Mass Velocity of Air/Height)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit)). Mass velocity of air is the amount of air travelling per unit area in a second, Height of the tower is the total length of the tower from the top to the bottom, Absolute humidity at final temperature is the quality of water vapor in the wet air of unit volume at the final equilibrium air temperature, The humidity of air at entry is the quantity of water vapor at wet air in the entrance of the tower & Humidity of air at exit is the quantity of water vapor at wet air in the exit of the tower.
How to calculate Gas phase mass transfer coefficient given humidity?
The Gas phase mass transfer coefficient given humidity formula is defined as the diffusivity of the gas phase to the boundary layer thickness is calculated using Gas Phase Mass Transfer Coefficient = (Mass Velocity of Air/Height)*ln((Absolute Humidity at Final Temperature-Humidity of air at entry)/(Absolute Humidity at Final Temperature-Humidity of air at exit)). To calculate Gas phase mass transfer coefficient given humidity, you need Mass Velocity of Air (G), Height (Z), Absolute Humidity at Final Temperature (Yi), Humidity of air at entry (Y1) & Humidity of air at exit (Y2). With our tool, you need to enter the respective value for Mass Velocity of Air, Height, Absolute Humidity at Final Temperature, Humidity of air at entry & Humidity of air at exit and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Gas Phase Mass Transfer Coefficient?
In this formula, Gas Phase Mass Transfer Coefficient uses Mass Velocity of Air, Height, Absolute Humidity at Final Temperature, Humidity of air at entry & Humidity of air at exit. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Gas Phase Mass Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))/(Enthalpy of Evaporation*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!