Head Loss given Amount of Hydropower Solution

STEP 0: Pre-Calculation Summary
Formula Used
Head Loss due to Friction = ((Amount of Hydropower/(9.81*Rate of Flow*Efficiency of Hydropower))-Head of Water)
hlocation = ((P/(9.81*qflow*η))-HWater)
This formula uses 5 Variables
Variables Used
Head Loss due to Friction - (Measured in Meter) - The Head Loss due to Friction occurs due to the effect of the fluid's viscosity near the surface of the pipe or duct.
Amount of Hydropower - (Measured in Watt) - Amount of Hydropower is a form of renewable energy that uses the water stored in dams, as well as flowing in rivers to create electricity in hydropower plants.
Rate of Flow - (Measured in Cubic Meter per Second) - Rate of Flow is the rate at which a liquid or other substance flows through a particular channel, pipe, etc.
Efficiency of Hydropower - Efficiency of Hydropower is the ratio of useful energy output generated from water flow compared to the input energy.
Head of Water - (Measured in Meter) - Head of Water is defined as the height of water columns.
STEP 1: Convert Input(s) to Base Unit
Amount of Hydropower: 0.77 Kilowatt --> 770 Watt (Check conversion here)
Rate of Flow: 32 Cubic Meter per Second --> 32 Cubic Meter per Second No Conversion Required
Efficiency of Hydropower: 0.8 --> No Conversion Required
Head of Water: 2.3 Meter --> 2.3 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
hlocation = ((P/(9.81*qflow*η))-HWater) --> ((770/(9.81*32*0.8))-2.3)
Evaluating ... ...
hlocation = 0.766067787971457
STEP 3: Convert Result to Output's Unit
0.766067787971457 Meter --> No Conversion Required
FINAL ANSWER
0.766067787971457 0.766068 Meter <-- Head Loss due to Friction
(Calculation completed in 00.004 seconds)

Credits

Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verified by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has verified this Calculator and 700+ more calculators!

11 Assessment of Available Power Calculators

Head Loss given Energy through Hydraulic Turbines
Go Head Loss due to Friction = -((Energy through Hydraulic Turbines/ (9.81*Rate of Flow*Efficiency of Hydropower*Time Period of Progressive Wave))-Head of Water)
Head given Energy through Hydraulic Turbines
Go Head of Water = (Energy through Hydraulic Turbines/ (9.81*Rate of Flow*Efficiency of Hydropower*Time Period of Progressive Wave))+Head Loss due to Friction
Efficiency of Hydropower Station given Energy through Hydraulic Turbines
Go Efficiency of Hydropower = Energy through Hydraulic Turbines/(9.81*Rate of Flow*(Head of Water-Head Loss due to Friction)*Time Period of Progressive Wave)
Rate of Flow of Water given Energy through Hydraulic Turbines
Go Rate of Flow = Energy through Hydraulic Turbines/(9.81*(Head of Water-Head Loss due to Friction)*Efficiency of Hydropower*Time Period of Progressive Wave)
Period of Flow given Energy through Hydraulic Turbines
Go Time Period of Progressive Wave = Energy through Hydraulic Turbines/(9.81*Rate of Flow*(Head of Water-Head Loss due to Friction)*Efficiency of Hydropower)
Energy through Hydraulic Turbines
Go Energy through Hydraulic Turbines = (9.81*Rate of Flow*(Head of Water-Head Loss due to Friction)*Efficiency of Hydropower*Time Period of Progressive Wave)
Amount of Hydropower
Go Amount of Hydropower = (Specific Weight of Liquid*Rate of Flow*(Head loss-Head of Water)*Efficiency of Hydropower)/1000
Effective Head given Energy through Hydraulic Turbines
Go Effective Head = Energy through Hydraulic Turbines/(9.81*Rate of Flow*Efficiency of Hydropower*Time Period of Progressive Wave)
Head Loss given Amount of Hydropower
Go Head Loss due to Friction = ((Amount of Hydropower/(9.81*Rate of Flow*Efficiency of Hydropower))-Head of Water)
Head given Amount of Hydropower
Go Head of Water = (Amount of Hydropower/(9.81*Rate of Flow*Efficiency of Hydropower))+Head Loss due to Friction
Efficiency of Hydropower Station given Amount of Hydropower
Go Efficiency of Hydropower = Amount of Hydropower/(9.81*Rate of Flow*(Head loss-Head of Water))

Head Loss given Amount of Hydropower Formula

Head Loss due to Friction = ((Amount of Hydropower/(9.81*Rate of Flow*Efficiency of Hydropower))-Head of Water)
hlocation = ((P/(9.81*qflow*η))-HWater)

What is meant by Rate of Flow of Water?

The flow rate of a liquid is a measure of the volume of liquid that moves in a certain amount of time. The flow rate depends on the area of the section.

How to Calculate Head Loss given Amount of Hydropower?

Head Loss given Amount of Hydropower calculator uses Head Loss due to Friction = ((Amount of Hydropower/(9.81*Rate of Flow*Efficiency of Hydropower))-Head of Water) to calculate the Head Loss due to Friction, The Head Loss given Amount of Hydropower is defined as the decrease in the total energy of a fluid flowing through a hydraulic system, resulting in a reduction of available hydropower output. Head Loss due to Friction is denoted by hlocation symbol.

How to calculate Head Loss given Amount of Hydropower using this online calculator? To use this online calculator for Head Loss given Amount of Hydropower, enter Amount of Hydropower (P), Rate of Flow (qflow), Efficiency of Hydropower (η) & Head of Water (HWater) and hit the calculate button. Here is how the Head Loss given Amount of Hydropower calculation can be explained with given input values -> 1.466068 = ((770/(9.81*32*0.8))-2.3).

FAQ

What is Head Loss given Amount of Hydropower?
The Head Loss given Amount of Hydropower is defined as the decrease in the total energy of a fluid flowing through a hydraulic system, resulting in a reduction of available hydropower output and is represented as hlocation = ((P/(9.81*qflow*η))-HWater) or Head Loss due to Friction = ((Amount of Hydropower/(9.81*Rate of Flow*Efficiency of Hydropower))-Head of Water). Amount of Hydropower is a form of renewable energy that uses the water stored in dams, as well as flowing in rivers to create electricity in hydropower plants, Rate of Flow is the rate at which a liquid or other substance flows through a particular channel, pipe, etc, Efficiency of Hydropower is the ratio of useful energy output generated from water flow compared to the input energy & Head of Water is defined as the height of water columns.
How to calculate Head Loss given Amount of Hydropower?
The Head Loss given Amount of Hydropower is defined as the decrease in the total energy of a fluid flowing through a hydraulic system, resulting in a reduction of available hydropower output is calculated using Head Loss due to Friction = ((Amount of Hydropower/(9.81*Rate of Flow*Efficiency of Hydropower))-Head of Water). To calculate Head Loss given Amount of Hydropower, you need Amount of Hydropower (P), Rate of Flow (qflow), Efficiency of Hydropower (η) & Head of Water (HWater). With our tool, you need to enter the respective value for Amount of Hydropower, Rate of Flow, Efficiency of Hydropower & Head of Water and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Head Loss due to Friction?
In this formula, Head Loss due to Friction uses Amount of Hydropower, Rate of Flow, Efficiency of Hydropower & Head of Water. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Head Loss due to Friction = -((Energy through Hydraulic Turbines/ (9.81*Rate of Flow*Efficiency of Hydropower*Time Period of Progressive Wave))-Head of Water)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!