Isentropic Temperature 2 given Specific Volume Solution

STEP 0: Pre-Calculation Summary
Formula Used
Isentropic temperature 2 given specific volume = Temperature of Surface 1*(Specific Volume at Point 1/Specific Volume at Point 2)^(Specific Heat Ratio Dynamic-1)
T2 specific volume = T1*(ν1/ν2)^(κ-1)
This formula uses 5 Variables
Variables Used
Isentropic temperature 2 given specific volume - (Measured in Kelvin) - Isentropic temperature 2 given specific volume is the temperature when the thermodynamic process is both adiabatic and reversible.
Temperature of Surface 1 - (Measured in Kelvin) - Temperature of Surface 1 is the temperature of the 1st surface.
Specific Volume at Point 1 - (Measured in Cubic Meter per Kilogram) - Specific Volume at Point 1 is the number of cubic meters occupied by one kilogram of matter. It is the ratio of a material's volume to its mass.
Specific Volume at Point 2 - (Measured in Cubic Meter per Kilogram) - Specific Volume at Point 2 is the number of cubic meters occupied by one kilogram of matter. It is the ratio of a material's volume to its mass.
Specific Heat Ratio Dynamic - The Specific Heat Ratio Dynamic is the ratio of the heat capacity at constant pressure to heat capacity at constant volume.
STEP 1: Convert Input(s) to Base Unit
Temperature of Surface 1: 101 Kelvin --> 101 Kelvin No Conversion Required
Specific Volume at Point 1: 0.001 Cubic Meter per Kilogram --> 0.001 Cubic Meter per Kilogram No Conversion Required
Specific Volume at Point 2: 0.816 Cubic Meter per Kilogram --> 0.816 Cubic Meter per Kilogram No Conversion Required
Specific Heat Ratio Dynamic: 1.392758 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
T2 specific volume = T1*(ν12)^(κ-1) --> 101*(0.001/0.816)^(1.392758-1)
Evaluating ... ...
T2 specific volume = 7.25657637278576
STEP 3: Convert Result to Output's Unit
7.25657637278576 Kelvin --> No Conversion Required
FINAL ANSWER
7.25657637278576 7.256576 Kelvin <-- Isentropic temperature 2 given specific volume
(Calculation completed in 00.004 seconds)

Credits

Created by Team Softusvista
Softusvista Office (Pune), India
Team Softusvista has created this Calculator and 600+ more calculators!
Verified by Himanshi Sharma
Bhilai Institute of Technology (BIT), Raipur
Himanshi Sharma has verified this Calculator and 800+ more calculators!

9 Isentropic Process Calculators

Isentropic Temperature 1 given Pressure Ratio
Go Isentropic temperature 1 given pressure ratio = Temperature of Surface 2/(Pressure 2/Pressure 1)^((Specific Heat Ratio Dynamic-1)/Specific Heat Ratio Dynamic)
Isentropic Temperature 2 given Pressure Ratio
Go Isentropic temperature 2 given pressure ratio = Temperature of Surface 1*(Pressure 2/Pressure 1)^((Specific Heat Ratio Dynamic-1)/Specific Heat Ratio Dynamic)
Isentropic Temperature 1 given Specific Volume
Go Isentropic temperature 1 given specific volume = Temperature of Surface 2/(Specific Volume at Point 1/Specific Volume at Point 2)^(Specific Heat Ratio Dynamic-1)
Isentropic Temperature 2 given Specific Volume
Go Isentropic temperature 2 given specific volume = Temperature of Surface 1*(Specific Volume at Point 1/Specific Volume at Point 2)^(Specific Heat Ratio Dynamic-1)
Isentropic Pressure at Point 1
Go Isentropic Pressure at point 1 = Pressure 2/(Specific Volume at Point 1/Specific Volume at Point 2)^Specific Heat Ratio Dynamic
Isentropic Pressure at Point 2
Go Isentropic Pressure at point 2 = Pressure 1*(Specific Volume at Point 1/Specific Volume at Point 2)^Specific Heat Ratio Dynamic
Temperature Ratio given Isentropic Pressure
Go Temperature Ratio Isentropic Pressure = (Pressure 2/Pressure 1)^((Specific Heat Ratio Dynamic-1)/Specific Heat Ratio Dynamic)
Temperature Ratio given Isentropic Specific Volume
Go Temperature ratio isentropic specific volume = (Specific Volume at Point 1/Specific Volume at Point 2)^(Specific Heat Ratio Dynamic-1)
Pressure Ratio in Isentropic Process
Go Pressure Ratio Isentropic Process = (Specific Volume at Point 1/Specific Volume at Point 2)^Specific Heat Ratio Dynamic

Isentropic Temperature 2 given Specific Volume Formula

Isentropic temperature 2 given specific volume = Temperature of Surface 1*(Specific Volume at Point 1/Specific Volume at Point 2)^(Specific Heat Ratio Dynamic-1)
T2 specific volume = T1*(ν1/ν2)^(κ-1)

What is Temperature at point 2 for an isentropic process?

The Temperature at point 2 for an isentropic process is the temperature when the thermodynamic system is both adiabatic and reversible. An isentropic process is one where there is no change in entropy. The temperature at point 2 can be calculated with the known values of temperature at point 1, specific volumes, and the ratio of specific heat.

How to Calculate Isentropic Temperature 2 given Specific Volume?

Isentropic Temperature 2 given Specific Volume calculator uses Isentropic temperature 2 given specific volume = Temperature of Surface 1*(Specific Volume at Point 1/Specific Volume at Point 2)^(Specific Heat Ratio Dynamic-1) to calculate the Isentropic temperature 2 given specific volume, Isentropic Temperature 2 given Specific Volume is the temperature when the thermodynamic process is both adiabatic and reversible. Isentropic temperature 2 given specific volume is denoted by T2 specific volume symbol.

How to calculate Isentropic Temperature 2 given Specific Volume using this online calculator? To use this online calculator for Isentropic Temperature 2 given Specific Volume, enter Temperature of Surface 1 (T1), Specific Volume at Point 1 1), Specific Volume at Point 2 2) & Specific Heat Ratio Dynamic (κ) and hit the calculate button. Here is how the Isentropic Temperature 2 given Specific Volume calculation can be explained with given input values -> 7.256576 = 101*(0.001/0.816)^(1.392758-1).

FAQ

What is Isentropic Temperature 2 given Specific Volume?
Isentropic Temperature 2 given Specific Volume is the temperature when the thermodynamic process is both adiabatic and reversible and is represented as T2 specific volume = T1*(ν12)^(κ-1) or Isentropic temperature 2 given specific volume = Temperature of Surface 1*(Specific Volume at Point 1/Specific Volume at Point 2)^(Specific Heat Ratio Dynamic-1). Temperature of Surface 1 is the temperature of the 1st surface, Specific Volume at Point 1 is the number of cubic meters occupied by one kilogram of matter. It is the ratio of a material's volume to its mass, Specific Volume at Point 2 is the number of cubic meters occupied by one kilogram of matter. It is the ratio of a material's volume to its mass & The Specific Heat Ratio Dynamic is the ratio of the heat capacity at constant pressure to heat capacity at constant volume.
How to calculate Isentropic Temperature 2 given Specific Volume?
Isentropic Temperature 2 given Specific Volume is the temperature when the thermodynamic process is both adiabatic and reversible is calculated using Isentropic temperature 2 given specific volume = Temperature of Surface 1*(Specific Volume at Point 1/Specific Volume at Point 2)^(Specific Heat Ratio Dynamic-1). To calculate Isentropic Temperature 2 given Specific Volume, you need Temperature of Surface 1 (T1), Specific Volume at Point 1 1), Specific Volume at Point 2 2) & Specific Heat Ratio Dynamic (κ). With our tool, you need to enter the respective value for Temperature of Surface 1, Specific Volume at Point 1, Specific Volume at Point 2 & Specific Heat Ratio Dynamic and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!