Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe Solution

STEP 0: Pre-Calculation Summary
Formula Used
Kinematic Viscosity = (Flow Velocity*Diameter of Pipe)/Reynolds Number
v = (Vf*Dp)/Re
This formula uses 4 Variables
Variables Used
Kinematic Viscosity - (Measured in Square Meter per Second) - The Kinematic Viscosity is an atmospheric variable defined as the ratio between the dynamic viscosity μ and the density ρ of the fluid.
Flow Velocity - (Measured in Meter per Second) - The Flow Velocity is the velocity of the flow of any fluid.
Diameter of Pipe - (Measured in Meter) - The Diameter of Pipe is the diameter of the pipe in which the liquid is flowing.
Reynolds Number - The Reynolds number is the ratio of inertial forces to viscous forces within a fluid which is subjected to relative internal movement due to different fluid velocities.
STEP 1: Convert Input(s) to Base Unit
Flow Velocity: 1.12 Meter per Second --> 1.12 Meter per Second No Conversion Required
Diameter of Pipe: 1.01 Meter --> 1.01 Meter No Conversion Required
Reynolds Number: 1560 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
v = (Vf*Dp)/Re --> (1.12*1.01)/1560
Evaluating ... ...
v = 0.000725128205128205
STEP 3: Convert Result to Output's Unit
0.000725128205128205 Square Meter per Second -->7.25128205128205 Stokes (Check conversion here)
FINAL ANSWER
7.25128205128205 7.251282 Stokes <-- Kinematic Viscosity
(Calculation completed in 00.004 seconds)

Credits

Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

7 Drill String Buckling Calculators

Column Slenderness Ratio for Critical Buckling Load
Go Column Slenderness Ratio = sqrt((Cross Section Area of Column*pi^2*Elastic Modulus)/Critical Buckling Load for Drill String)
Critical Buckling Load
Go Critical Buckling Load for Drill String = Cross Section Area of Column*((pi^2*Elastic Modulus)/(Column Slenderness Ratio^2))
Cross Section Area of Column for Critical Buckling Load
Go Cross Section Area of Column = (Critical Buckling Load for Drill String*Column Slenderness Ratio^2)/(pi^2*Elastic Modulus)
Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe
Go Kinematic Viscosity = (Flow Velocity*Diameter of Pipe)/Reynolds Number
Flow Velocity given Reynolds Number in Shorter Length of Pipe
Go Flow Velocity = (Reynolds Number*Kinematic Viscosity)/Diameter of Pipe
Pipe Diameter given Reynolds Number in Shorter Length of Pipe
Go Diameter of Pipe = (Reynolds Number*Kinematic Viscosity)/Flow Velocity
Reynolds Number in Shorter Length of Pipe
Go Reynolds Number = (Flow Velocity*Diameter of Pipe)/Kinematic Viscosity

Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe Formula

Kinematic Viscosity = (Flow Velocity*Diameter of Pipe)/Reynolds Number
v = (Vf*Dp)/Re

What is slenderness ratio?

The slenderness ratio is defined as the ratio of length l to the radius of gyration k, represented as l/k. When the slenderness ratio exceeds a value of 100 for a strong slim column, failure by buckling can be expected. Columns of stiffer and more brittle materials will buckle at lower slenderness ratios.

How to Calculate Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe?

Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe calculator uses Kinematic Viscosity = (Flow Velocity*Diameter of Pipe)/Reynolds Number to calculate the Kinematic Viscosity, The Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe is a measure of a fluid's internal resistance to flow under gravitational forces. It is determined by measuring the time in seconds, required for a fixed volume of fluid to flow a known distance by gravity through a capillary within a calibrated viscometer at a closely controlled temperature. Kinematic Viscosity is denoted by v symbol.

How to calculate Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe using this online calculator? To use this online calculator for Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe, enter Flow Velocity (Vf), Diameter of Pipe (Dp) & Reynolds Number (Re) and hit the calculate button. Here is how the Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe calculation can be explained with given input values -> 72512.82 = (1.12*1.01)/1560.

FAQ

What is Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe?
The Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe is a measure of a fluid's internal resistance to flow under gravitational forces. It is determined by measuring the time in seconds, required for a fixed volume of fluid to flow a known distance by gravity through a capillary within a calibrated viscometer at a closely controlled temperature and is represented as v = (Vf*Dp)/Re or Kinematic Viscosity = (Flow Velocity*Diameter of Pipe)/Reynolds Number. The Flow Velocity is the velocity of the flow of any fluid, The Diameter of Pipe is the diameter of the pipe in which the liquid is flowing & The Reynolds number is the ratio of inertial forces to viscous forces within a fluid which is subjected to relative internal movement due to different fluid velocities.
How to calculate Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe?
The Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe is a measure of a fluid's internal resistance to flow under gravitational forces. It is determined by measuring the time in seconds, required for a fixed volume of fluid to flow a known distance by gravity through a capillary within a calibrated viscometer at a closely controlled temperature is calculated using Kinematic Viscosity = (Flow Velocity*Diameter of Pipe)/Reynolds Number. To calculate Kinematic Viscosity of Fluid given Reynolds Number in Shorter Length of Pipe, you need Flow Velocity (Vf), Diameter of Pipe (Dp) & Reynolds Number (Re). With our tool, you need to enter the respective value for Flow Velocity, Diameter of Pipe & Reynolds Number and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!