Length of Settling Zone given Height at Outlet Zone with respect to Discharge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed)
L = (H*Q)/(w*h*v')
This formula uses 6 Variables
Variables Used
Length - (Measured in Meter) - Length is the measurement or extent of something from end to end.
Outer Height - (Measured in Meter) - Outer Height is the length of outer side of 2D cross section.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Width - (Measured in Meter) - Width is the measurement or extent of something from side to side.
Height of Crack - (Measured in Meter) - Height of Crack is the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress.
Falling Speed - (Measured in Meter per Second) - Falling Speed is the speed of the particle having smaller diameter.
STEP 1: Convert Input(s) to Base Unit
Outer Height: 40 Meter --> 40 Meter No Conversion Required
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Width: 2.29 Meter --> 2.29 Meter No Conversion Required
Height of Crack: 12000 Millimeter --> 12 Meter (Check conversion here)
Falling Speed: 0.1 Meter per Second --> 0.1 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
L = (H*Q)/(w*h*v') --> (40*1.01)/(2.29*12*0.1)
Evaluating ... ...
L = 14.7016011644833
STEP 3: Convert Result to Output's Unit
14.7016011644833 Meter --> No Conversion Required
FINAL ANSWER
14.7016011644833 14.7016 Meter <-- Length
(Calculation completed in 00.020 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

4 Length of Settling Zone Calculators

Length of Settling Zone given Height at Outlet Zone with respect to Discharge
Go Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed)
Length of Settling Zone given Detention Time
Go Length = (Detention time*Discharge)/(Width*Height of Crack)
Length of Settling Zone given Vertical Falling Speed in Sedimentation Tank
Go Length = Discharge/(Settling Velocity*Width)
Length of Settling Zone given Surface Area of Sedimentation Tank
Go Length = Area/Width

Length of Settling Zone given Height at Outlet Zone with respect to Discharge Formula

Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed)
L = (H*Q)/(w*h*v')

What is discharge ?

The discharge in the stream represents the run-off in the stream at a given section and includes surface run-off as well as ground water flow.

How to Calculate Length of Settling Zone given Height at Outlet Zone with respect to Discharge?

Length of Settling Zone given Height at Outlet Zone with respect to Discharge calculator uses Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed) to calculate the Length, Length of Settling Zone given Height at Outlet Zone with respect to Discharge formula is defined as linear distance from one end to another. Length is denoted by L symbol.

How to calculate Length of Settling Zone given Height at Outlet Zone with respect to Discharge using this online calculator? To use this online calculator for Length of Settling Zone given Height at Outlet Zone with respect to Discharge, enter Outer Height (H), Discharge (Q), Width (w), Height of Crack (h) & Falling Speed (v') and hit the calculate button. Here is how the Length of Settling Zone given Height at Outlet Zone with respect to Discharge calculation can be explained with given input values -> 14.7016 = (40*1.01)/(2.29*12*0.1).

FAQ

What is Length of Settling Zone given Height at Outlet Zone with respect to Discharge?
Length of Settling Zone given Height at Outlet Zone with respect to Discharge formula is defined as linear distance from one end to another and is represented as L = (H*Q)/(w*h*v') or Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed). Outer Height is the length of outer side of 2D cross section, Discharge is the rate of flow of a liquid, Width is the measurement or extent of something from side to side, Height of Crack is the size of a flaw or crack in a material that can lead to catastrophic failure under a given stress & Falling Speed is the speed of the particle having smaller diameter.
How to calculate Length of Settling Zone given Height at Outlet Zone with respect to Discharge?
Length of Settling Zone given Height at Outlet Zone with respect to Discharge formula is defined as linear distance from one end to another is calculated using Length = (Outer Height*Discharge)/(Width*Height of Crack*Falling Speed). To calculate Length of Settling Zone given Height at Outlet Zone with respect to Discharge, you need Outer Height (H), Discharge (Q), Width (w), Height of Crack (h) & Falling Speed (v'). With our tool, you need to enter the respective value for Outer Height, Discharge, Width, Height of Crack & Falling Speed and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Length?
In this formula, Length uses Outer Height, Discharge, Width, Height of Crack & Falling Speed. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Length = Discharge/(Settling Velocity*Width)
  • Length = (Detention time*Discharge)/(Width*Height of Crack)
  • Length = Area/Width
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!