How to Calculate MLSS Returned given Oxygen Required in Aeration Tank?
MLSS Returned given Oxygen Required in Aeration Tank calculator uses MLSS in returned or wasted sludge = (((Sewage Discharge*(Influent BOD-Effluent BOD))/Ratio of BOD to Ultimate BOD)-Theoretical Oxygen Requirement)/(1.42*Volume of Wasted Sludge per day) to calculate the MLSS in returned or wasted sludge, MLSS Returned given Oxygen Required in Aeration Tank calculates MLSS returned when we have prior information of other parameters used. MLSS in returned or wasted sludge is denoted by XR symbol.
How to calculate MLSS Returned given Oxygen Required in Aeration Tank using this online calculator? To use this online calculator for MLSS Returned given Oxygen Required in Aeration Tank, enter Sewage Discharge (Qs), Influent BOD (Qi), Effluent BOD (Qo), Ratio of BOD to Ultimate BOD (f), Theoretical Oxygen Requirement (O2) & Volume of Wasted Sludge per day (Qw) and hit the calculate button. Here is how the MLSS Returned given Oxygen Required in Aeration Tank calculation can be explained with given input values -> 5003.706 = (((10*(0.0112-0.0004))/1.6)-2.89351851851852E-11)/(1.42*9.5).