Positive Sequence Voltage (LLF)
Positive Sequence Voltage=(Fault Impedance *Positive Sequence Current )+Negative Sequence Voltage GO
Negative Sequence Impedance For Delta Connected Load
Negative Sequence Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Negative Sequence Impedance For Star Connected Load
Negative Sequence Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Negative Sequence Impedance For Transformer
Negative Sequence Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Negative Phase Current For Delta Connected Load
Negative Sequence Current =3*Negative Sequence Voltage/Delta Impedance GO
Leakage Impedance For transformer Using Negative Sequence Voltage
Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Leakage Impedance For Transformer Using Negative Sequence Current
Leakage Impedance=Negative Sequence Voltage/Negative Sequence Current GO
Delta Impedance For Delta Connected Load Using Negative Sequence Voltage
Delta Impedance =Negative Sequence Voltage/Negative Sequence Current GO
Star Impedance For Star Connected Load Using Negative Sequence Voltage
Star Impedance =Negative Sequence Voltage/Negative Sequence Current GO
Star Impedance For Star Connected Load Using Negative Sequence Current
Star Impedance =Negative Sequence Voltage/Negative Sequence Current GO
Negative Sequence Current For Star Connected Load
Negative Sequence Current =Negative Sequence Voltage/Star Impedance GO

11 Other formulas that calculate the same Output

Negative Sequence Current Using a-phase EMF (LGF)
Negative Sequence Current =EMF Induced In The Primary Winding/(Zero Sequence Impedance+Negative Sequence Impedance+Positive Sequence Impedance+(3*Fault Impedance )) GO
Negative Sequence Current Using Negative Sequence Voltage (LLGF)
Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance GO
Negative Sequence Current Using Negative Sequence Impedance(1OC)
Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance GO
Negative Sequence Current for L-G-F
Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance GO
Negative Sequence Current Using Positive Sequence Current (1OC)
Negative Sequence Current =((-1)*Positive Sequence Current )-Zero Sequence Current GO
Negative Phase Current For Delta Connected Load
Negative Sequence Current =3*Negative Sequence Voltage/Delta Impedance GO
Negative Sequence Current For Star Connected Load
Negative Sequence Current =Negative Sequence Voltage/Star Impedance GO
Negative Sequence Current(LLF)
Negative Sequence Current =(-1)*Positive Sequence Current GO
Negative Sequence Current (3oc)
Negative Sequence Current =(0)*Electric Current GO
Negative Sequence Current Using a-Phase Current (LGF)
Negative Sequence Current =a-phase Current /3 GO
Negative Sequence Current (2OC)
Negative Sequence Current =a-phase Current /3 GO

Negative Sequence Current Using Negative Sequence Voltage (2OC) Formula

Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance
I2=(-1)*V2/Z2
More formulas
b-phase Current (2OC) GO
c-phase Current (2OC) GO
a-phase Current (2OC) GO
Potential Difference Between b-phase (2OC) GO
Potential Difference Between c-phase (2OC) GO
Potential Difference Between a-phase (2OC) GO
Positive Sequence Current (2OC) GO
Negative Sequence Current (2OC) GO
Zero Sequence Current (2OC) GO
Positive Sequence Potential Difference (2OC) GO
Negative Sequence Potential Difference (2OC) GO
Zero Sequence Potential Difference (2OC) GO
Zero Sequence Potential Difference Using Potential Difference Between b-Phase(2OC) GO
Positive Sequence Current Using Positive Sequence Voltage (2OC) GO
Positive Sequence Impedance Using Positive Sequence Voltage (2OC) GO
Negative Sequence Impedance Using Negative Sequence Voltage (2OC) GO
Zero Sequence Current Using Zero Sequence Voltage (2OC) GO
Zero Sequence Impedance Using Zero Sequence Voltage (2OC) GO
Zero Sequence Voltage Using Zero Sequence Current (2OC) GO
Positive Sequence Voltage Using Positive Sequence Current (2OC) GO
Negative Sequence Voltage Using Negative Sequence Current (2OC) GO
a-phase EMF Using Positive Sequence Voltage (2OC) GO
a-phase EMF Using Positive Sequence Current (2OC) GO
Zero Sequence Impedance Using a-phase EMf (2OC) GO
Positive Sequence Impedance Using a-phase EMf (2OC) GO
Negative Sequence Impedance Using a-phase EMf (2OC) GO
Positive Sequence Current Using a-phase EMf (2OC) GO

Define two open conductor fault.

When two phases of a balanced three-phase line open it creates an unbalance in the system and results in the flow of unbalanced currents. Such conditions occur in the system when one or two conductors of a transmission line are broken due to storms or if fuses, isolators, or circuit breakers operate only on one or two phases leaving others connected.

How to Calculate Negative Sequence Current Using Negative Sequence Voltage (2OC)?

Negative Sequence Current Using Negative Sequence Voltage (2OC) calculator uses Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance to calculate the Negative Sequence Current , The Negative Sequence Current Using Negative Sequence Voltage (2OC) formula is consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation. Negative Sequence Current and is denoted by I2 symbol.

How to calculate Negative Sequence Current Using Negative Sequence Voltage (2OC) using this online calculator? To use this online calculator for Negative Sequence Current Using Negative Sequence Voltage (2OC), enter Negative Sequence Voltage (V2) and Negative Sequence Impedance (Z2) and hit the calculate button. Here is how the Negative Sequence Current Using Negative Sequence Voltage (2OC) calculation can be explained with given input values -> -5.714286 = (-1)*4/0.7.

FAQ

What is Negative Sequence Current Using Negative Sequence Voltage (2OC)?
The Negative Sequence Current Using Negative Sequence Voltage (2OC) formula is consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation and is represented as I2=(-1)*V2/Z2 or Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance. Negative Sequence Voltage consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation and Negative Sequence Impedance consists of balanced three-phase impedance phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation.
How to calculate Negative Sequence Current Using Negative Sequence Voltage (2OC)?
The Negative Sequence Current Using Negative Sequence Voltage (2OC) formula is consists of balanced three-phase current phasors which are exactly at 120 degrees apart rotating counterclockwise in ACB rotation is calculated using Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance. To calculate Negative Sequence Current Using Negative Sequence Voltage (2OC), you need Negative Sequence Voltage (V2) and Negative Sequence Impedance (Z2). With our tool, you need to enter the respective value for Negative Sequence Voltage and Negative Sequence Impedance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Negative Sequence Current ?
In this formula, Negative Sequence Current uses Negative Sequence Voltage and Negative Sequence Impedance. We can use 11 other way(s) to calculate the same, which is/are as follows -
  • Negative Sequence Current =Negative Sequence Voltage/Star Impedance
  • Negative Sequence Current =3*Negative Sequence Voltage/Delta Impedance
  • Negative Sequence Current =a-phase Current /3
  • Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance
  • Negative Sequence Current =EMF Induced In The Primary Winding/(Zero Sequence Impedance+Negative Sequence Impedance+Positive Sequence Impedance+(3*Fault Impedance ))
  • Negative Sequence Current =(-1)*Positive Sequence Current
  • Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance
  • Negative Sequence Current =((-1)*Positive Sequence Current )-Zero Sequence Current
  • Negative Sequence Current =(-1)*Negative Sequence Voltage/Negative Sequence Impedance
  • Negative Sequence Current =a-phase Current /3
  • Negative Sequence Current =(0)*Electric Current