Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit Solution

STEP 0: Pre-Calculation Summary
Formula Used
Oxygen Equivalent = Critical oxygen deficit*Self purification constant/(10^(-Deoxygenation Constant*Critical time))
Lt = Dc*f/(10^(-KD*tc))
This formula uses 5 Variables
Variables Used
Oxygen Equivalent - (Measured in Kilogram per Cubic Meter) - Oxygen Equivalent is the oxidisable organic matter present in sewage.
Critical oxygen deficit - Critical oxygen deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate.
Self purification constant - Self purification constant is the ratio of reoxygenation constant to deoxygenation constant.
Deoxygenation Constant - (Measured in 1 Per Second) - Deoxygenation Constant is the value obtained after decomposing of oxygen in sewage.
Critical time - (Measured in Second) - Critical time is the time after which the minimum dissolved oxygen occurs can be found by differentiating the equation.
STEP 1: Convert Input(s) to Base Unit
Critical oxygen deficit: 6 --> No Conversion Required
Self purification constant: 0.6 --> No Conversion Required
Deoxygenation Constant: 0.23 1 Per Day --> 2.66203703703704E-06 1 Per Second (Check conversion here)
Critical time: 0.5 Day --> 43200 Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Lt = Dc*f/(10^(-KD*tc)) --> 6*0.6/(10^(-2.66203703703704E-06*43200))
Evaluating ... ...
Lt = 4.69140040242828
STEP 3: Convert Result to Output's Unit
4.69140040242828 Kilogram per Cubic Meter -->4691.40040242828 Milligram per Liter (Check conversion here)
FINAL ANSWER
4691.40040242828 4691.4 Milligram per Liter <-- Oxygen Equivalent
(Calculation completed in 00.020 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 600+ more calculators!

6 Oxygen Equivalent Calculators

Oxygen Equivalent given DO Deficit using Streeter-Phelps Equation
Go Organic Matter at Start = Oxygen Deficit/(Deoxygenation Constant/(Reoxygenation coefficient-Deoxygenation Constant))*(10^(-Deoxygenation Constant*Time in days)-10^(-Reoxygenation coefficient*Time in days)+Initial oxygen deficit*10^(-Reoxygenation coefficient*Time in days))
Oxygen Equivalent in First Stage Equation
Go Oxygen Equivalent = ((Critical oxygen deficit*Self purification constant)^(Self purification constant-1)*Self purification constant*(1-(Self purification constant-1)*Initial oxygen deficit)^(1/Self purification constant))
Oxygen Equivalent given Critical Time in Self Purification Factor
Go Oxygen Equivalent = Critical oxygen deficit*(Self purification constant-1)/(1-((10^(Critical time*Deoxygenation Constant*(Self purification constant-1)))/Self purification constant))
Oxygen Equivalent given Critical Oxygen Deficit
Go Oxygen Equivalent = Critical oxygen deficit*Reoxygenation coefficient/(Deoxygenation Constant*10^(-Deoxygenation Constant*Critical time))
Oxygen Equivalent given Log value of Critical Oxygen Deficit
Go Oxygen Equivalent = Self purification constant*10^(log10(Critical oxygen deficit)+(Deoxygenation Constant*Critical time))
Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit
Go Oxygen Equivalent = Critical oxygen deficit*Self purification constant/(10^(-Deoxygenation Constant*Critical time))

Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit Formula

Oxygen Equivalent = Critical oxygen deficit*Self purification constant/(10^(-Deoxygenation Constant*Critical time))
Lt = Dc*f/(10^(-KD*tc))

What is critical oxygen deficit?

The Critical oxygen deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate.

How to Calculate Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit?

Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit calculator uses Oxygen Equivalent = Critical oxygen deficit*Self purification constant/(10^(-Deoxygenation Constant*Critical time)) to calculate the Oxygen Equivalent, The Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit is defined as the amount of oxygen equivalents consumed in the chemical oxidation of organic matter by strong oxidant. Oxygen Equivalent is denoted by Lt symbol.

How to calculate Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit using this online calculator? To use this online calculator for Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit, enter Critical oxygen deficit (Dc), Self purification constant (f), Deoxygenation Constant (KD) & Critical time (tc) and hit the calculate button. Here is how the Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit calculation can be explained with given input values -> 4.7E+6 = 6*0.6/(10^(-2.66203703703704E-06*43200)).

FAQ

What is Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit?
The Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit is defined as the amount of oxygen equivalents consumed in the chemical oxidation of organic matter by strong oxidant and is represented as Lt = Dc*f/(10^(-KD*tc)) or Oxygen Equivalent = Critical oxygen deficit*Self purification constant/(10^(-Deoxygenation Constant*Critical time)). Critical oxygen deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate, Self purification constant is the ratio of reoxygenation constant to deoxygenation constant, Deoxygenation Constant is the value obtained after decomposing of oxygen in sewage & Critical time is the time after which the minimum dissolved oxygen occurs can be found by differentiating the equation.
How to calculate Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit?
The Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit is defined as the amount of oxygen equivalents consumed in the chemical oxidation of organic matter by strong oxidant is calculated using Oxygen Equivalent = Critical oxygen deficit*Self purification constant/(10^(-Deoxygenation Constant*Critical time)). To calculate Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit, you need Critical oxygen deficit (Dc), Self purification constant (f), Deoxygenation Constant (KD) & Critical time (tc). With our tool, you need to enter the respective value for Critical oxygen deficit, Self purification constant, Deoxygenation Constant & Critical time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Oxygen Equivalent?
In this formula, Oxygen Equivalent uses Critical oxygen deficit, Self purification constant, Deoxygenation Constant & Critical time. We can use 4 other way(s) to calculate the same, which is/are as follows -
  • Oxygen Equivalent = Critical oxygen deficit*Reoxygenation coefficient/(Deoxygenation Constant*10^(-Deoxygenation Constant*Critical time))
  • Oxygen Equivalent = Self purification constant*10^(log10(Critical oxygen deficit)+(Deoxygenation Constant*Critical time))
  • Oxygen Equivalent = Critical oxygen deficit*(Self purification constant-1)/(1-((10^(Critical time*Deoxygenation Constant*(Self purification constant-1)))/Self purification constant))
  • Oxygen Equivalent = ((Critical oxygen deficit*Self purification constant)^(Self purification constant-1)*Self purification constant*(1-(Self purification constant-1)*Initial oxygen deficit)^(1/Self purification constant))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!