Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen Solution

STEP 0: Pre-Calculation Summary
Formula Used
Oxygen Transferred = (Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)
N = (Ns*D*f*(1.024)^(T-20))/(9.17)
This formula uses 5 Variables
Variables Used
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred under field condition.
Oxygen transfer capacity - (Measured in Kilogram per Second per Watt) - Oxygen transfer capacity under standard conditions.
Difference between saturation DO and operation DO - (Measured in Kilogram per Cubic Meter) - Difference between saturation DO and operation DO is the value obtained after subtracting operation DO from saturation DO.
Correction Factor - Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Oxygen transfer capacity: 2 Kilogram per Hour per Kilowatt --> 5.55555555555556E-07 Kilogram per Second per Watt (Check conversion here)
Difference between saturation DO and operation DO: 3 Milligram per Liter --> 0.003 Kilogram per Cubic Meter (Check conversion here)
Correction Factor: 0.5 --> No Conversion Required
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
N = (Ns*D*f*(1.024)^(T-20))/(9.17) --> (5.55555555555556E-07*0.003*0.5*(1.024)^(85-20))/(9.17)
Evaluating ... ...
N = 4.24567356638053E-10
STEP 3: Convert Result to Output's Unit
4.24567356638053E-10 Kilogram per Second per Watt -->0.00152844248389699 Kilogram per Hour per Kilowatt (Check conversion here)
FINAL ANSWER
0.00152844248389699 0.001528 Kilogram per Hour per Kilowatt <-- Oxygen Transferred
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

9 Oxygen Transfer Capacity Calculators

Oxygen Transfer Capacity under Standard Conditions
Go Oxygen transfer capacity = Oxygen Transferred/(((Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Correction Factor when Oxygen Transfer Capacity
Go Correction Factor = Oxygen Transferred/((Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field Conditions
Go Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17)
Oxygen transfer capacity given difference between saturation and operation dissolved oxygen
Go Oxygen transfer capacity = Oxygen Transferred/((Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen
Go Oxygen Transferred = (Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)
Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.85
Go Oxygen transfer capacity = Oxygen Transferred/(((Dissolved oxygen saturation-Operation dissolved oxygen)*0.85*(1.024)^(Temperature-20))/(9.17))
Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8
Go Oxygen transfer capacity = Oxygen Transferred/(((Dissolved oxygen saturation-Operation dissolved oxygen)*0.8*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field Conditions when Correction Factor is 0.85
Go Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.85*(1.024)^(Temperature-20))/(9.17)
Oxygen Transferred under Field Conditions when Correction Factor is 0.8
Go Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.8*(1.024)^(Temperature-20))/(9.17)

Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen Formula

Oxygen Transferred = (Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)
N = (Ns*D*f*(1.024)^(T-20))/(9.17)

What is aeration tank ?

Aeration in an activated sludge process is based on pumping air into a tank, which promotes the microbial growth in the wastewater. The microbes feed on the organic material, forming flocks which can easily settle out.

How to Calculate Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen?

Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen calculator uses Oxygen Transferred = (Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17) to calculate the Oxygen Transferred, The Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen calculates the oxygen transferred under field condition when we have prior information of other parameters used. Oxygen Transferred is denoted by N symbol.

How to calculate Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen using this online calculator? To use this online calculator for Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen, enter Oxygen transfer capacity (Ns), Difference between saturation DO and operation DO (D), Correction Factor (f) & Temperature (T) and hit the calculate button. Here is how the Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen calculation can be explained with given input values -> 5502.393 = (5.55555555555556E-07*0.003*0.5*(1.024)^(85-20))/(9.17).

FAQ

What is Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen?
The Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen calculates the oxygen transferred under field condition when we have prior information of other parameters used and is represented as N = (Ns*D*f*(1.024)^(T-20))/(9.17) or Oxygen Transferred = (Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17). Oxygen transfer capacity under standard conditions, Difference between saturation DO and operation DO is the value obtained after subtracting operation DO from saturation DO, Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error & Temperature is the degree or intensity of heat present in a substance or object.
How to calculate Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen?
The Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen calculates the oxygen transferred under field condition when we have prior information of other parameters used is calculated using Oxygen Transferred = (Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17). To calculate Oxygen Transferred under field given difference between saturation and Operation Dissolved Oxygen, you need Oxygen transfer capacity (Ns), Difference between saturation DO and operation DO (D), Correction Factor (f) & Temperature (T). With our tool, you need to enter the respective value for Oxygen transfer capacity, Difference between saturation DO and operation DO, Correction Factor & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Oxygen Transferred?
In this formula, Oxygen Transferred uses Oxygen transfer capacity, Difference between saturation DO and operation DO, Correction Factor & Temperature. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17)
  • Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.8*(1.024)^(Temperature-20))/(9.17)
  • Oxygen Transferred = (Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.85*(1.024)^(Temperature-20))/(9.17)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!