Peak Average Output Voltage of Three-Phase Full Converters Solution

STEP 0: Pre-Calculation Summary
Formula Used
Peak Output Voltage 3 Phase Full Converter = (5.2*Peak Input Voltage 3 Phase Full Converter)/pi
Vom(3Φ-full) = (5.2*Vin(3Φ-full))/pi
This formula uses 1 Constants, 2 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Peak Output Voltage 3 Phase Full Converter - (Measured in Volt) - Peak Output Voltage 3 Phase Full Converter is defined as the peak amplitude obtained by the voltage at the output terminal of a full converter circuit.
Peak Input Voltage 3 Phase Full Converter - (Measured in Volt) - Peak Input Voltage 3 Phase Full Converter is defined as the peak amplitude obtained by the voltage at the input terminal of a full converter circuit.
STEP 1: Convert Input(s) to Base Unit
Peak Input Voltage 3 Phase Full Converter: 220 Volt --> 220 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vom(3Φ-full) = (5.2*Vin(3Φ-full))/pi --> (5.2*220)/pi
Evaluating ... ...
Vom(3Φ-full) = 364.146509794257
STEP 3: Convert Result to Output's Unit
364.146509794257 Volt --> No Conversion Required
FINAL ANSWER
364.146509794257 364.1465 Volt <-- Peak Output Voltage 3 Phase Full Converter
(Calculation completed in 00.004 seconds)

Credits

Created by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has created this Calculator and 50+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

5 Three Phase Full Converter Calculators

RMS Output Voltage for Phase Controller
Go RMS Output Voltage Full Converter = sqrt(((Peak Voltage)^2/pi)*int((sin(x))^2,x,(60+Firing Angle of Thyristor Converter),(120+Firing Angle of Thyristor Converter)))
RMS Output Voltage of Three-Phase Full Converter
Go RMS Output Voltage 3 Phase Full Converter = ((6)^0.5)*Peak Input Voltage 3 Phase Full Converter*((0.25+0.65*(cos(2*Delay Angle of 3 Phase Full Converter))/pi)^0.5)
Average Output Voltage for Three-Phase Converter
Go Average Voltage 3 Phase Full Converter = (2*Peak Phase Voltage Full Converter*cos(Delay Angle of 3 Phase Full Converter/2))/pi
Peak Average Output Voltage of Three-Phase Full Converters
Go Peak Output Voltage 3 Phase Full Converter = (5.2*Peak Input Voltage 3 Phase Full Converter)/pi
Normalized Average Output Voltage in Three-Phase Full-Converter
Go Normalized Output Voltage 3 Phase Full Converter = (cos(Delay Angle of 3 Phase Full Converter))

Peak Average Output Voltage of Three-Phase Full Converters Formula

Peak Output Voltage 3 Phase Full Converter = (5.2*Peak Input Voltage 3 Phase Full Converter)/pi
Vom(3Φ-full) = (5.2*Vin(3Φ-full))/pi

What are three phase full converters? What are their applications?

A three-phase full converter is a fully controlled bridge-controlled rectifier using six thyristors connected in the form of a full-wave bridge configuration. All the six thyristors are controlled switches that are turned on at appropriate times by applying suitable gate trigger signals. These are extensively used in industrial applications up to the 120 kW level.

How to Calculate Peak Average Output Voltage of Three-Phase Full Converters?

Peak Average Output Voltage of Three-Phase Full Converters calculator uses Peak Output Voltage 3 Phase Full Converter = (5.2*Peak Input Voltage 3 Phase Full Converter)/pi to calculate the Peak Output Voltage 3 Phase Full Converter, The Peak Average Output Voltage of Three-Phase Full Converters formula is the maximum average output voltage that can occur at the output of the converter and the condition for this is that the delay angle is 0 degrees. Peak Output Voltage 3 Phase Full Converter is denoted by Vom(3Φ-full) symbol.

How to calculate Peak Average Output Voltage of Three-Phase Full Converters using this online calculator? To use this online calculator for Peak Average Output Voltage of Three-Phase Full Converters, enter Peak Input Voltage 3 Phase Full Converter (Vin(3Φ-full)) and hit the calculate button. Here is how the Peak Average Output Voltage of Three-Phase Full Converters calculation can be explained with given input values -> 364.1465 = (5.2*220)/pi.

FAQ

What is Peak Average Output Voltage of Three-Phase Full Converters?
The Peak Average Output Voltage of Three-Phase Full Converters formula is the maximum average output voltage that can occur at the output of the converter and the condition for this is that the delay angle is 0 degrees and is represented as Vom(3Φ-full) = (5.2*Vin(3Φ-full))/pi or Peak Output Voltage 3 Phase Full Converter = (5.2*Peak Input Voltage 3 Phase Full Converter)/pi. Peak Input Voltage 3 Phase Full Converter is defined as the peak amplitude obtained by the voltage at the input terminal of a full converter circuit.
How to calculate Peak Average Output Voltage of Three-Phase Full Converters?
The Peak Average Output Voltage of Three-Phase Full Converters formula is the maximum average output voltage that can occur at the output of the converter and the condition for this is that the delay angle is 0 degrees is calculated using Peak Output Voltage 3 Phase Full Converter = (5.2*Peak Input Voltage 3 Phase Full Converter)/pi. To calculate Peak Average Output Voltage of Three-Phase Full Converters, you need Peak Input Voltage 3 Phase Full Converter (Vin(3Φ-full)). With our tool, you need to enter the respective value for Peak Input Voltage 3 Phase Full Converter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!