Peak Flow Rate given Volume of Each Grit Chamber Solution

STEP 0: Pre-Calculation Summary
Formula Used
Peak flow rate = (Volume*7.48*24*60)/Detention time
Qp = (VT*7.48*24*60)/Td
This formula uses 3 Variables
Variables Used
Peak flow rate - (Measured in Cubic Meter per Second) - Peak flow rate is defined as volumetric flow rate of peak flow.
Volume - (Measured in Cubic Meter) - Volume is the amount of space that a substance or object occupies or that is enclosed within a container.
Detention time - (Measured in Second) - Detention time is the length of time water is retained in a vessel or basin.
STEP 1: Convert Input(s) to Base Unit
Volume: 0.63 Cubic Meter --> 0.63 Cubic Meter No Conversion Required
Detention time: 3 Minute --> 180 Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qp = (VT*7.48*24*60)/Td --> (0.63*7.48*24*60)/180
Evaluating ... ...
Qp = 37.6992
STEP 3: Convert Result to Output's Unit
37.6992 Cubic Meter per Second --> No Conversion Required
FINAL ANSWER
37.6992 Cubic Meter per Second <-- Peak flow rate
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

16 Design of an Aerated Grit Chamber Calculators

Width using Length of Grit Chamber
Go Width of grit chamber = (Volume/(Depth of grit chamber*Length of grit chamber))
Depth given Length of Grit Chamber
Go Depth of grit chamber = (Volume/(Length of grit chamber*Width of grit chamber))
Length of Grit Chamber
Go Length of grit chamber = (Volume/(Width of grit chamber*Depth of grit chamber))
Volume using Length of Grit Chamber
Go Volume = (Length of grit chamber*Width of grit chamber*Depth of grit chamber)
Width of Grit Chamber
Go Width of grit chamber = (Selected width ratio*Depth of grit chamber)
Selected Width-Ratio given Width of Grit Chamber
Go Selected width ratio = Width of grit chamber/Depth of grit chamber
Chosen Depth given Width of Grit Chamber
Go Depth of grit chamber = Width of grit chamber/Selected width ratio
Chamber Length using Air supply required
Go Length of grit chamber = (Chosen air supply/Air supply required)
Chosen Air Supply given Air supply required
Go Chosen air supply = Air supply required*Length of grit chamber
Air supply required in Grit Chamber
Go Air supply required = Chosen air supply/Length of grit chamber
Assumed Grit Quantity given Volume of Aerated Grit Chamber
Go Assumed grit quantity = (Volume/Volumetric Flow Rate)
Volume Flow Rate given Volume of Aerated Grit Chamber
Go Volumetric Flow Rate = (Volume/Assumed grit quantity)
Volume of Each Grit Chamber
Go Volume = (Peak flow rate*Detention time)/(7.48*24*60)
Peak Flow Rate given Volume of Each Grit Chamber
Go Peak flow rate = (Volume*7.48*24*60)/Detention time
Detention Time given Volume of each Grit Chamber
Go Detention time = (Volume*7.48*24*60)/Peak flow rate
Volume of Aerated Grit Chamber
Go Volume = Assumed grit quantity*Volumetric Flow Rate

Peak Flow Rate given Volume of Each Grit Chamber Formula

Peak flow rate = (Volume*7.48*24*60)/Detention time
Qp = (VT*7.48*24*60)/Td

What is volumetric flow rate ?

The volumetric flow rate is the volume of fluid which passes per unit time; usually it is represented by the symbol Q. The SI unit is cubic metres per second.

How to Calculate Peak Flow Rate given Volume of Each Grit Chamber?

Peak Flow Rate given Volume of Each Grit Chamber calculator uses Peak flow rate = (Volume*7.48*24*60)/Detention time to calculate the Peak flow rate, The Peak Flow Rate given Volume of Each Grit Chamber calculates the peak flow rate when we have prior information of volume of grit chamber and detention time. Peak flow rate is denoted by Qp symbol.

How to calculate Peak Flow Rate given Volume of Each Grit Chamber using this online calculator? To use this online calculator for Peak Flow Rate given Volume of Each Grit Chamber, enter Volume (VT) & Detention time (Td) and hit the calculate button. Here is how the Peak Flow Rate given Volume of Each Grit Chamber calculation can be explained with given input values -> 37.6992 = (0.63*7.48*24*60)/180.

FAQ

What is Peak Flow Rate given Volume of Each Grit Chamber?
The Peak Flow Rate given Volume of Each Grit Chamber calculates the peak flow rate when we have prior information of volume of grit chamber and detention time and is represented as Qp = (VT*7.48*24*60)/Td or Peak flow rate = (Volume*7.48*24*60)/Detention time. Volume is the amount of space that a substance or object occupies or that is enclosed within a container & Detention time is the length of time water is retained in a vessel or basin.
How to calculate Peak Flow Rate given Volume of Each Grit Chamber?
The Peak Flow Rate given Volume of Each Grit Chamber calculates the peak flow rate when we have prior information of volume of grit chamber and detention time is calculated using Peak flow rate = (Volume*7.48*24*60)/Detention time. To calculate Peak Flow Rate given Volume of Each Grit Chamber, you need Volume (VT) & Detention time (Td). With our tool, you need to enter the respective value for Volume & Detention time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!