Positive Sequence Current using A-Phase EMF (Two Conductor Open) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO)
I1(tco) = Ea(tco)/(Z0(tco)+Z1(tco)+Z2(tco))
This formula uses 5 Variables
Variables Used
Positive Sequence Current in TCO - (Measured in Ampere) - Positive Sequence Current in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
A Phase EMF in TCO - (Measured in Volt) - A Phase EMF in TCO is defined as the electromagnetic force of the a-phase in open conductor fault.
Zero Sequence Impedance in TCO - (Measured in Ohm) - Zero Sequence Impedance in TCO is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counter clockwise together.
Positive Sequence Impedance in TCO - (Measured in Ohm) - Positive Sequence Impedance in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation.
Negative Sequence Impedance in TCO - (Measured in Ohm) - Negative Sequence Impedance in TCO in open conductor fault is consists of balanced three-phase impedance phasors which are exactly at 120 degrees apart.
STEP 1: Convert Input(s) to Base Unit
A Phase EMF in TCO: 121.38 Volt --> 121.38 Volt No Conversion Required
Zero Sequence Impedance in TCO: 7.96 Ohm --> 7.96 Ohm No Conversion Required
Positive Sequence Impedance in TCO: 7.95 Ohm --> 7.95 Ohm No Conversion Required
Negative Sequence Impedance in TCO: 44.5 Ohm --> 44.5 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
I1(tco) = Ea(tco)/(Z0(tco)+Z1(tco)+Z2(tco)) --> 121.38/(7.96+7.95+44.5)
Evaluating ... ...
I1(tco) = 2.00926998841251
STEP 3: Convert Result to Output's Unit
2.00926998841251 Ampere --> No Conversion Required
FINAL ANSWER
2.00926998841251 2.00927 Ampere <-- Positive Sequence Current in TCO
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

7 Positive Sequence Calculators

Positive Sequence Impedance using A-Phase EMF (Two Conductor Open)
​ Go Positive Sequence Impedance in TCO = (A Phase EMF in TCO/Positive Sequence Current in TCO)-Zero Sequence Impedance in TCO-Negative Sequence Impedance in TCO
Positive Sequence Current using A-Phase EMF (Two Conductor Open)
​ Go Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO)
Positive Sequence Impedance using Positive Sequence Voltage (Two Conductor Open)
​ Go Positive Sequence Impedance in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Current in TCO
Positive Sequence Current using Positive Sequence Voltage (Two Conductor Open)
​ Go Positive Sequence Current in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Impedance in TCO
Positive Sequence Voltage using Positive Sequence Current (Two Conductor Open)
​ Go Positive Sequence Voltage in TCO = A Phase EMF in TCO-Positive Sequence Current in TCO*Positive Sequence Impedance in TCO
Positive Sequence Potential Difference (Two Conductor Open)
​ Go Positive Sequence Potential Difference in TCO = ((-1)*Negative Sequence Potential Difference in TCO)-Zero Sequence Potential Difference in TCO
Positive Sequence Current (Two Conductor Open)
​ Go Positive Sequence Current in TCO = A-Phase Current in TCO/3

Positive Sequence Current using A-Phase EMF (Two Conductor Open) Formula

Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO)
I1(tco) = Ea(tco)/(Z0(tco)+Z1(tco)+Z2(tco))

Define two open conductor fault.

When two phases of a balanced three-phase line open it creates an unbalance in the system and results in the flow of unbalanced currents. Such conditions occur in the system when one or two conductors of a transmission line are broken due to storms or if fuses, isolators, or circuit breakers operate only on one or two phases leaving others connected.

How to Calculate Positive Sequence Current using A-Phase EMF (Two Conductor Open)?

Positive Sequence Current using A-Phase EMF (Two Conductor Open) calculator uses Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO) to calculate the Positive Sequence Current in TCO, The Positive Sequence Current using A-Phase EMF (Two conductor open) formula is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation. Positive Sequence Current in TCO is denoted by I1(tco) symbol.

How to calculate Positive Sequence Current using A-Phase EMF (Two Conductor Open) using this online calculator? To use this online calculator for Positive Sequence Current using A-Phase EMF (Two Conductor Open), enter A Phase EMF in TCO (Ea(tco)), Zero Sequence Impedance in TCO (Z0(tco)), Positive Sequence Impedance in TCO (Z1(tco)) & Negative Sequence Impedance in TCO (Z2(tco)) and hit the calculate button. Here is how the Positive Sequence Current using A-Phase EMF (Two Conductor Open) calculation can be explained with given input values -> 2.009603 = 121.38/(7.96+7.95+44.5).

FAQ

What is Positive Sequence Current using A-Phase EMF (Two Conductor Open)?
The Positive Sequence Current using A-Phase EMF (Two conductor open) formula is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation and is represented as I1(tco) = Ea(tco)/(Z0(tco)+Z1(tco)+Z2(tco)) or Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO). A Phase EMF in TCO is defined as the electromagnetic force of the a-phase in open conductor fault, Zero Sequence Impedance in TCO is consists of a balanced three-phase voltage and current, phasors of which all have the same phase angles and rotate counter clockwise together, Positive Sequence Impedance in TCO is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation & Negative Sequence Impedance in TCO in open conductor fault is consists of balanced three-phase impedance phasors which are exactly at 120 degrees apart.
How to calculate Positive Sequence Current using A-Phase EMF (Two Conductor Open)?
The Positive Sequence Current using A-Phase EMF (Two conductor open) formula is consists of balanced three-phase voltage and current phasors which are exactly at 120 degrees apart rotating counterclockwise in ABC rotation is calculated using Positive Sequence Current in TCO = A Phase EMF in TCO/(Zero Sequence Impedance in TCO+Positive Sequence Impedance in TCO+Negative Sequence Impedance in TCO). To calculate Positive Sequence Current using A-Phase EMF (Two Conductor Open), you need A Phase EMF in TCO (Ea(tco)), Zero Sequence Impedance in TCO (Z0(tco)), Positive Sequence Impedance in TCO (Z1(tco)) & Negative Sequence Impedance in TCO (Z2(tco)). With our tool, you need to enter the respective value for A Phase EMF in TCO, Zero Sequence Impedance in TCO, Positive Sequence Impedance in TCO & Negative Sequence Impedance in TCO and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Positive Sequence Current in TCO?
In this formula, Positive Sequence Current in TCO uses A Phase EMF in TCO, Zero Sequence Impedance in TCO, Positive Sequence Impedance in TCO & Negative Sequence Impedance in TCO. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Positive Sequence Current in TCO = A-Phase Current in TCO/3
  • Positive Sequence Current in TCO = (A Phase EMF in TCO-Positive Sequence Voltage in TCO)/Positive Sequence Impedance in TCO
Let Others Know