Power Required for Refrigeration System Solution

STEP 0: Pre-Calculation Summary
Formula Used
Input Power = (Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Actual temperature of Rammed Air))/60
Pin = (ma*Cp*(Tt'-T2'))/60
This formula uses 5 Variables
Variables Used
Input Power - (Measured in Watt) - Input Power is the power, which is required by the appliance at its input i.e., from the plug point.
Mass of Air - (Measured in Kilogram per Minute) - Mass of air is both a property of air and a measure of its resistance to acceleration when a net force is applied.
Specific Heat Capacity at Constant Pressure - (Measured in Joule per Kilogram per K) - Specific Heat Capacity at Constant Pressure means the amount of heat that is required to raise the temperature of a unit mass of gas by 1 degree at constant pressure.
Actual End Temp of Isentropic Compression - (Measured in Kelvin) - Actual End Temp of Isentropic Compression is greater than the ideal temperature.
Actual temperature of Rammed Air - (Measured in Kelvin) - Actual temperature of Rammed Air is equal to the ideal temperature of Rammed Air.
STEP 1: Convert Input(s) to Base Unit
Mass of Air: 120 Kilogram per Minute --> 120 Kilogram per Minute No Conversion Required
Specific Heat Capacity at Constant Pressure: 1.005 Kilojoule per Kilogram per K --> 1005 Joule per Kilogram per K (Check conversion here)
Actual End Temp of Isentropic Compression: 350 Kelvin --> 350 Kelvin No Conversion Required
Actual temperature of Rammed Air: 273 Kelvin --> 273 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pin = (ma*Cp*(Tt'-T2'))/60 --> (120*1005*(350-273))/60
Evaluating ... ...
Pin = 154770
STEP 3: Convert Result to Output's Unit
154770 Watt -->9286.19999999998 Kilojoule per Minute (Check conversion here)
FINAL ANSWER
9286.19999999998 9286.2 Kilojoule per Minute <-- Input Power
(Calculation completed in 00.004 seconds)

Credits

Created by Rushi Shah
K J Somaiya College of Engineering (K J Somaiya), Mumbai
Rushi Shah has created this Calculator and 25+ more calculators!
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

11 Simple Air Cooling System Calculators

Power required to maintain pressure inside cabin excluding ram work
Go Input Power = ((Mass of Air*Specific Heat Capacity at Constant Pressure*Actual temperature of Rammed Air)/(Compressor Efficiency))*((Cabin Pressure/Pressure of Rammed Air)^((Heat Capacity Ratio-1)/Heat Capacity Ratio)-1)
Power Required to Maintain Pressure inside Cabin including Ram Work
Go Input Power = ((Mass of Air*Specific Heat Capacity at Constant Pressure*Ambient Air Temperature)/(Compressor Efficiency))*((Cabin Pressure/Atmospheric Pressure)^((Heat Capacity Ratio-1)/Heat Capacity Ratio)-1)
C.O.P. of simple air cycle
Go Actual Coefficient of Performance = (Inside temperature of cabin-Actual temperature at end of isentropic expansion)/(Actual End Temp of Isentropic Compression-Actual temperature of Rammed Air)
Mass of air to produce Q tonnes of refrigeration
Go Mass of Air = (210*Tonnage of Refrigeration in TR)/(Specific Heat Capacity at Constant Pressure*(Inside temperature of cabin-Actual temperature at end of isentropic expansion))
Expansion Work
Go Work Done per min = Mass of Air*Specific Heat Capacity at Constant Pressure*(Temperature at the end of cooling process-Actual temperature at end of isentropic expansion)
Refrigeration Effect Produced
Go Refrigeration Effect Produced = Mass of Air*Specific Heat Capacity at Constant Pressure*(Inside temperature of cabin-Actual temperature at end of isentropic expansion)
Heat rejected during cooling process
Go Heat Rejected = Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Temperature at the end of cooling process)
Compression Work
Go Work Done per min = Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Actual temperature of Rammed Air)
Power Required for Refrigeration System
Go Input Power = (Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Actual temperature of Rammed Air))/60
Temperature Ratio at Start and End of Ramming Process
Go Temperature Ratio = 1+(Velocity^2*(Heat Capacity Ratio-1))/(2*Heat Capacity Ratio*[R]*Initial Temperature)
COP of Air Cycle for given Input Power and Tonnage of Refrigeration
Go Actual Coefficient of Performance = (210*Tonnage of Refrigeration in TR)/(Input Power*60)

Power Required for Refrigeration System Formula

Input Power = (Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Actual temperature of Rammed Air))/60
Pin = (ma*Cp*(Tt'-T2'))/60

When is the work done in an air cycle?

Work is done on the air during the compression process, which results in an increase of the temperature and pressure of the air.

How to Calculate Power Required for Refrigeration System?

Power Required for Refrigeration System calculator uses Input Power = (Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Actual temperature of Rammed Air))/60 to calculate the Input Power, The Power Required for Refrigeration System formula is defined as work done on the air during the compression per unit time. Input Power is denoted by Pin symbol.

How to calculate Power Required for Refrigeration System using this online calculator? To use this online calculator for Power Required for Refrigeration System, enter Mass of Air (ma), Specific Heat Capacity at Constant Pressure (Cp), Actual End Temp of Isentropic Compression (Tt') & Actual temperature of Rammed Air (T2') and hit the calculate button. Here is how the Power Required for Refrigeration System calculation can be explained with given input values -> 557.172 = (2*1005*(350-273))/60.

FAQ

What is Power Required for Refrigeration System?
The Power Required for Refrigeration System formula is defined as work done on the air during the compression per unit time and is represented as Pin = (ma*Cp*(Tt'-T2'))/60 or Input Power = (Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Actual temperature of Rammed Air))/60. Mass of air is both a property of air and a measure of its resistance to acceleration when a net force is applied, Specific Heat Capacity at Constant Pressure means the amount of heat that is required to raise the temperature of a unit mass of gas by 1 degree at constant pressure, Actual End Temp of Isentropic Compression is greater than the ideal temperature & Actual temperature of Rammed Air is equal to the ideal temperature of Rammed Air.
How to calculate Power Required for Refrigeration System?
The Power Required for Refrigeration System formula is defined as work done on the air during the compression per unit time is calculated using Input Power = (Mass of Air*Specific Heat Capacity at Constant Pressure*(Actual End Temp of Isentropic Compression-Actual temperature of Rammed Air))/60. To calculate Power Required for Refrigeration System, you need Mass of Air (ma), Specific Heat Capacity at Constant Pressure (Cp), Actual End Temp of Isentropic Compression (Tt') & Actual temperature of Rammed Air (T2'). With our tool, you need to enter the respective value for Mass of Air, Specific Heat Capacity at Constant Pressure, Actual End Temp of Isentropic Compression & Actual temperature of Rammed Air and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Input Power?
In this formula, Input Power uses Mass of Air, Specific Heat Capacity at Constant Pressure, Actual End Temp of Isentropic Compression & Actual temperature of Rammed Air. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Input Power = ((Mass of Air*Specific Heat Capacity at Constant Pressure*Actual temperature of Rammed Air)/(Compressor Efficiency))*((Cabin Pressure/Pressure of Rammed Air)^((Heat Capacity Ratio-1)/Heat Capacity Ratio)-1)
  • Input Power = ((Mass of Air*Specific Heat Capacity at Constant Pressure*Ambient Air Temperature)/(Compressor Efficiency))*((Cabin Pressure/Atmospheric Pressure)^((Heat Capacity Ratio-1)/Heat Capacity Ratio)-1)
Let Others Know