Power to be Transmitted given Power Rating of Chain Solution

STEP 0: Pre-Calculation Summary
Formula Used
Power Transmitted by Chain Drive = Power Rating of Chain*Multiple Strand Factor*Tooth Correction Factor/Service Factor of Chain Drive
Pc = kW*k1*k2/Ks
This formula uses 5 Variables
Variables Used
Power Transmitted by Chain Drive - (Measured in Watt) - Power Transmitted by Chain Drive is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Power Rating of Chain - (Measured in Watt) - The Power Rating of Chain is the highest power input allowed to flow through the chain.
Multiple Strand Factor - The Multiple Strand Factor is a factor to account for the roller chain made up of two or more strands assembled as a single structure on pins.
Tooth Correction Factor - Tooth Correction Factor is the factor of correction for the undercuts of the tooth.
Service Factor of Chain Drive - Service Factor of Chain Drive is defined as the ratio of the torque capacity and the rated torque value.
STEP 1: Convert Input(s) to Base Unit
Power Rating of Chain: 4.5 Kilowatt --> 4500 Watt (Check conversion here)
Multiple Strand Factor: 3.3 --> No Conversion Required
Tooth Correction Factor: 1.05 --> No Conversion Required
Service Factor of Chain Drive: 1.7 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pc = kW*k1*k2/Ks --> 4500*3.3*1.05/1.7
Evaluating ... ...
Pc = 9172.05882352941
STEP 3: Convert Result to Output's Unit
9172.05882352941 Watt -->9.17205882352941 Kilowatt (Check conversion here)
FINAL ANSWER
9.17205882352941 9.172059 Kilowatt <-- Power Transmitted by Chain Drive
(Calculation completed in 00.020 seconds)

Credits

Created by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has created this Calculator and 1000+ more calculators!
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

8 Power Rating of Roller Chains Calculators

Tooth Correction Factor given Power Rating of Chain
Go Tooth Correction Factor = Power Transmitted by Chain Drive*Service Factor of Chain Drive/(Multiple Strand Factor*Power Rating of Chain)
Multiple Strand Factor given Power Rating of Chain
Go Multiple Strand Factor = Power Transmitted by Chain Drive*Service Factor of Chain Drive/(Power Rating of Chain*Tooth Correction Factor)
Power Rating of Chain
Go Power Rating of Chain = Power Transmitted by Chain Drive*Service Factor of Chain Drive/(Multiple Strand Factor*Tooth Correction Factor)
Power to be Transmitted given Power Rating of Chain
Go Power Transmitted by Chain Drive = Power Rating of Chain*Multiple Strand Factor*Tooth Correction Factor/Service Factor of Chain Drive
Service Factor given Power Rating of Chain
Go Service Factor of Chain Drive = Power Rating of Chain*Multiple Strand Factor*Tooth Correction Factor/Power Transmitted by Chain Drive
Allowable Tension in Chain given Power Transmitted by Roller Chain
Go Allowable Tension in Chain = Power Transmitted by Chain Drive/Average Chain Velocity
Average Velocity of Chain given Power Transmitted by Roller Chain
Go Average Chain Velocity = Power Transmitted by Chain Drive/Allowable Tension in Chain
Power Transmitted by Roller Chain
Go Power Transmitted by Chain Drive = Allowable Tension in Chain*Average Chain Velocity

Power to be Transmitted given Power Rating of Chain Formula

Power Transmitted by Chain Drive = Power Rating of Chain*Multiple Strand Factor*Tooth Correction Factor/Service Factor of Chain Drive
Pc = kW*k1*k2/Ks

Define a Chain Drive?

Chain drive is a way of transmitting mechanical power from one place to another. It is often used to convey power to the wheels of a vehicle, particularly bicycles and motorcycles. It is also used in a wide variety of machines besides vehicles.

How to Calculate Power to be Transmitted given Power Rating of Chain?

Power to be Transmitted given Power Rating of Chain calculator uses Power Transmitted by Chain Drive = Power Rating of Chain*Multiple Strand Factor*Tooth Correction Factor/Service Factor of Chain Drive to calculate the Power Transmitted by Chain Drive, The Power to be Transmitted given Power Rating of Chain formula is defined as amount of power that is being transmitted using chain drives. Power Transmitted by Chain Drive is denoted by Pc symbol.

How to calculate Power to be Transmitted given Power Rating of Chain using this online calculator? To use this online calculator for Power to be Transmitted given Power Rating of Chain, enter Power Rating of Chain (kW), Multiple Strand Factor (k1), Tooth Correction Factor (k2) & Service Factor of Chain Drive (Ks) and hit the calculate button. Here is how the Power to be Transmitted given Power Rating of Chain calculation can be explained with given input values -> 0.009172 = 4500*3.3*1.05/1.7.

FAQ

What is Power to be Transmitted given Power Rating of Chain?
The Power to be Transmitted given Power Rating of Chain formula is defined as amount of power that is being transmitted using chain drives and is represented as Pc = kW*k1*k2/Ks or Power Transmitted by Chain Drive = Power Rating of Chain*Multiple Strand Factor*Tooth Correction Factor/Service Factor of Chain Drive. The Power Rating of Chain is the highest power input allowed to flow through the chain, The Multiple Strand Factor is a factor to account for the roller chain made up of two or more strands assembled as a single structure on pins, Tooth Correction Factor is the factor of correction for the undercuts of the tooth & Service Factor of Chain Drive is defined as the ratio of the torque capacity and the rated torque value.
How to calculate Power to be Transmitted given Power Rating of Chain?
The Power to be Transmitted given Power Rating of Chain formula is defined as amount of power that is being transmitted using chain drives is calculated using Power Transmitted by Chain Drive = Power Rating of Chain*Multiple Strand Factor*Tooth Correction Factor/Service Factor of Chain Drive. To calculate Power to be Transmitted given Power Rating of Chain, you need Power Rating of Chain (kW), Multiple Strand Factor (k1), Tooth Correction Factor (k2) & Service Factor of Chain Drive (Ks). With our tool, you need to enter the respective value for Power Rating of Chain, Multiple Strand Factor, Tooth Correction Factor & Service Factor of Chain Drive and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Power Transmitted by Chain Drive?
In this formula, Power Transmitted by Chain Drive uses Power Rating of Chain, Multiple Strand Factor, Tooth Correction Factor & Service Factor of Chain Drive. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Power Transmitted by Chain Drive = Allowable Tension in Chain*Average Chain Velocity
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!