Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 500+ more calculators!
Anirudh Singh
National Institute of Technology (NIT), Jamshedpur
Anirudh Singh has verified this Calculator and 100+ more calculators!

11 Other formulas that you can solve using the same Inputs

Equivalent Resistance From Primary Side When Secondary Winding Resistance
Equivalent resistance of transformer from primary=Resistance of primary winding+(Resistance of Secondary winding/(Voltage Transformation Ratio*Voltage Transformation Ratio)) GO
Secondary Winding Resistance When Equivalent Resistance From Primary Side Is Given
Resistance of Secondary winding=(Equivalent resistance of transformer from primary-Resistance of primary winding)*Voltage Transformation Ratio*Voltage Transformation Ratio GO
Equivalent Resistance From Secondary Side When Primary Winding Resistance
Equivalent resistance from Secondary=Resistance of Secondary winding+(Resistance of primary winding/(Voltage Transformation Ratio*Voltage Transformation Ratio)) GO
Impedance Of Primary Winding
Impedance of primary winding=sqrt((Resistance of primary winding*Resistance of primary winding)+(Primary leakage Reactance*Primary leakage Reactance)) GO
Voltage Transformation Ratio When Equivalent Resistance From Primary Side Is Given
Voltage Transformation Ratio=sqrt(Resistance of Secondary winding/(Equivalent resistance of transformer from primary-Resistance of primary winding)) GO
Voltage Transformation Ratio When Secondary Leakage Resistance Is Given
Voltage Transformation Ratio=sqrt(Resistance of Secondary winding/(Equivalent resistance of transformer from primary-Resistance of primary winding)) GO
Voltage Transformation Ratio When Primary Leakage Resistance Is Given
Voltage Transformation Ratio=sqrt(Resistance of primary winding/(Equivalent resistance from Secondary-Resistance of Secondary winding)) GO
Resistance Of Primary Winding In Secondary
Resistance of Primary winding in Secondary=Resistance of primary winding*Voltage Transformation Ratio*Voltage Transformation Ratio GO
Resistance Of Secondary In Primary When Equivalent Resistance From Primary Side Is Given
Resistance of Secondary winding in primary=Equivalent resistance of transformer from primary-Resistance of primary winding GO
Equivalent Resistance Of Transformer From Primary Side
Equivalent resistance of transformer from primary=Resistance of Secondary winding in primary+Resistance of primary winding GO
Input Voltage When EMF Induced In Primary Winding Is Given
voltage1=EMF Induced In The Primary Winding+(Electric Current in Conductor 1*Impedance of primary winding) GO

2 Other formulas that calculate the same Output

Primary Leakage Reactance When Equivalent Reactance From Secondary Side Is Given
Primary leakage Reactance=Equivalent reactance from primary-(Secondary leakage Reactance/(Voltage Transformation Ratio*Voltage Transformation Ratio)) GO
Primary Leakage Reactance
Primary leakage Reactance=Reactance of Primary in Secondary/(Voltage Transformation Ratio*Voltage Transformation Ratio) GO

Primary Winding Reactance When Impedance Of Primary Winding Is Given Formula

Primary leakage Reactance=sqrt(Impedance of primary winding*Impedance of primary winding-Resistance of primary winding*Resistance of primary winding)
X1=sqrt(Z1*Z1-R1*R1)
More formulas
Primary Voltage When Voltage Transformation Ratio Is Given GO
Secondary Voltage When Voltage Transformation Ratio Is Given GO
Secondary Current When Voltage Transformation Ratio Is Given GO
Primary Current When Voltage Transformation Ratio Is Given GO
Secondary Leakage Reactance GO
Primary Leakage Reactance GO
Self-Induced EMF In Primary GO
Self-Induced EMF In Secondary GO
Secondary Current When Secondary Leakage Reactance Is Given GO
Primary Current When Primary Leakage Reactance Is Given GO
The Reactance Of Primary Winding In Secondary GO
The Reactance Of Secondary Winding In Primary GO
The Equivalent Reactance Of Transformer From Primary Side GO
The Equivalent Reactance Of Transformer From Secondary Side GO
Resistance Of Secondary Winding In Primary GO
Resistance Of Primary Winding In Secondary GO
Primary Winding Resistance GO
Secondary Winding Resistance GO
Equivalent Impedance Of Transformer From Primary Side GO
Equivalent Impedance Of Transformer From Secondary Side GO
Reactance Of Primary In Secondary When Equivalent Reactance From Secondary Side Is Given GO
Reactance Of Secondary In primary When Equivalent Reactance From primary Side Is Given GO
Resistance Of Secondary In Primary When Equivalent Resistance From Primary Side Is Given GO
Resistance Of Primary In Secondary When Equivalent Resistance From Secondary Side Is Given GO
Secondary Winding Resistance When Equivalent Resistance From Primary Side Is Given GO
Primary Winding Resistance When Equivalent Resistance From Secondary Side Is Given GO
Primary Winding Resistance When Secondary Winding Resistance Is Given GO
Secondary Winding Resistance When Primary Winding Resistance Is Given GO
Secondary Leakage Reactance When Equivalent Reactance From Secondary Side Is Given GO
Primary Leakage Reactance When Equivalent Reactance From Secondary Side Is Given GO
Secondary Leakage Reactance When Equivalent Reactance From Primary Side Is Given GO
Secondary Winding Resistance When Impedance Of Secondary Winding Is Given GO
Primary Winding Resistance When Impedance Of Primary Winding Is Given GO
Secondary Winding Reactance When Impedance Of Secondary Winding Is Given GO
Secondary Current When Output Voltage Is Given GO
Primary Current When Input Voltage Is Given GO

What type of winding is used in a transformer?

In core type, we wrap the primary, and secondary windings on the outside limbs, and in shell type, we place the primary and secondary windings on the inner limbs. We use concentric type windings in core type transformer. We place a low voltage winding near the core. However, to reduce leakage reactance, windings can be interlaced.

How to Calculate Primary Winding Reactance When Impedance Of Primary Winding Is Given?

Primary Winding Reactance When Impedance Of Primary Winding Is Given calculator uses Primary leakage Reactance=sqrt(Impedance of primary winding*Impedance of primary winding-Resistance of primary winding*Resistance of primary winding) to calculate the Primary leakage Reactance, The Primary Winding Reactance When Impedance Of Primary Winding Is Given formula is defined as the reactance of Secondary winding. Primary leakage Reactance and is denoted by X1 symbol.

How to calculate Primary Winding Reactance When Impedance Of Primary Winding Is Given using this online calculator? To use this online calculator for Primary Winding Reactance When Impedance Of Primary Winding Is Given, enter Impedance of primary winding (Z1) and Resistance of primary winding (R1) and hit the calculate button. Here is how the Primary Winding Reactance When Impedance Of Primary Winding Is Given calculation can be explained with given input values -> 3.872983 = sqrt(4*4-1*1).

FAQ

What is Primary Winding Reactance When Impedance Of Primary Winding Is Given?
The Primary Winding Reactance When Impedance Of Primary Winding Is Given formula is defined as the reactance of Secondary winding and is represented as X1=sqrt(Z1*Z1-R1*R1) or Primary leakage Reactance=sqrt(Impedance of primary winding*Impedance of primary winding-Resistance of primary winding*Resistance of primary winding). The impedance of primary winding is the total of primary resistance and Reactance and Resistance of primary winding is the resistance of primary winding .
How to calculate Primary Winding Reactance When Impedance Of Primary Winding Is Given?
The Primary Winding Reactance When Impedance Of Primary Winding Is Given formula is defined as the reactance of Secondary winding is calculated using Primary leakage Reactance=sqrt(Impedance of primary winding*Impedance of primary winding-Resistance of primary winding*Resistance of primary winding). To calculate Primary Winding Reactance When Impedance Of Primary Winding Is Given, you need Impedance of primary winding (Z1) and Resistance of primary winding (R1). With our tool, you need to enter the respective value for Impedance of primary winding and Resistance of primary winding and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Primary leakage Reactance?
In this formula, Primary leakage Reactance uses Impedance of primary winding and Resistance of primary winding. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Primary leakage Reactance=Reactance of Primary in Secondary/(Voltage Transformation Ratio*Voltage Transformation Ratio)
  • Primary leakage Reactance=Equivalent reactance from primary-(Secondary leakage Reactance/(Voltage Transformation Ratio*Voltage Transformation Ratio))
Share Image
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!