Proportionality constant given specific capacity per unit well area of aquifer Solution

STEP 0: Pre-Calculation Summary
Formula Used
Proportionality Constant = Area of the Well*Specific Capacity
K0 = A*Ks
This formula uses 3 Variables
Variables Used
Proportionality Constant - The proportionality constant depends upon the characteristics of the aquifer and the area of the well. It represents discharge per unit drawdown also called specific capacity of well.
Area of the Well - (Measured in Square Meter) - Area of the Well is denoted by A symbol.
Specific Capacity - Specific Capacity is the amount of water furnished under a standard unit head.
STEP 1: Convert Input(s) to Base Unit
Area of the Well: 20 Square Meter --> 20 Square Meter No Conversion Required
Specific Capacity: 0.75 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K0 = A*Ks --> 20*0.75
Evaluating ... ...
K0 = 15
STEP 3: Convert Result to Output's Unit
15 --> No Conversion Required
FINAL ANSWER
15 <-- Proportionality Constant
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verifier Image
Verified by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has verified this Calculator and 900+ more calculators!

9 Recuperation Test Calculators

Proportionality constant per unit well area of aquifer
​ Go Proportionality Constant = Area of the Well*((1/Time Interval)*ln(Drawdown at the Start of Recuperation/Drawdown at a Time))
Equation for Time Interval
​ Go Time Interval = (Area of the Well/Proportionality Constant)*ln(Drawdown at the Start of Recuperation/Drawdown at a Time)
Area of well given time interval
​ Go Area of the Well = Proportionality Constant*Time Interval/ln(Drawdown at the Start of Recuperation/Drawdown at a Time)
Depression Head when Discharge from Open Well is Considered
​ Go Depression Head = Yield from an open well/(Specific Capacity*Area of the Well)
Area of well when discharged from open well is considered
​ Go Area of the Well = Yield from an open well/(Specific Capacity*Depression Head)
Discharge from Open Well under Depression Head
​ Go Yield from an open well = Specific Capacity*Area of the Well*Depression Head
Specific Capacity per unit Well Area for Discharge from Open Well
​ Go Specific Capacity = Flow Discharge/(Area of the Well*Depression Head)
Proportionality constant given specific capacity per unit well area of aquifer
​ Go Proportionality Constant = Area of the Well*Specific Capacity
Area of well given specific capacity per unit well area of aquifer
​ Go Area of the Well = Proportionality Constant/Specific Capacity

Proportionality constant given specific capacity per unit well area of aquifer Formula

Proportionality Constant = Area of the Well*Specific Capacity
K0 = A*Ks

What is Groundwater Recharge?

Groundwater Recharge or deep drainage or deep percolation is a hydrologic process, where water moves downward from surface water to groundwater. Recharge is the primary method through which water enters an aquifer.

How to Calculate Proportionality constant given specific capacity per unit well area of aquifer?

Proportionality constant given specific capacity per unit well area of aquifer calculator uses Proportionality Constant = Area of the Well*Specific Capacity to calculate the Proportionality Constant, Proportionality constant given specific capacity per unit well area of aquifer is defined as aquifer parameter depending on characteristic of aquifer and area of well, which also represents discharge per unit drawdown. Proportionality Constant is denoted by K0 symbol.

How to calculate Proportionality constant given specific capacity per unit well area of aquifer using this online calculator? To use this online calculator for Proportionality constant given specific capacity per unit well area of aquifer, enter Area of the Well (A) & Specific Capacity (Ks) and hit the calculate button. Here is how the Proportionality constant given specific capacity per unit well area of aquifer calculation can be explained with given input values -> 15 = 20*0.75.

FAQ

What is Proportionality constant given specific capacity per unit well area of aquifer?
Proportionality constant given specific capacity per unit well area of aquifer is defined as aquifer parameter depending on characteristic of aquifer and area of well, which also represents discharge per unit drawdown and is represented as K0 = A*Ks or Proportionality Constant = Area of the Well*Specific Capacity. Area of the Well is denoted by A symbol & Specific Capacity is the amount of water furnished under a standard unit head.
How to calculate Proportionality constant given specific capacity per unit well area of aquifer?
Proportionality constant given specific capacity per unit well area of aquifer is defined as aquifer parameter depending on characteristic of aquifer and area of well, which also represents discharge per unit drawdown is calculated using Proportionality Constant = Area of the Well*Specific Capacity. To calculate Proportionality constant given specific capacity per unit well area of aquifer, you need Area of the Well (A) & Specific Capacity (Ks). With our tool, you need to enter the respective value for Area of the Well & Specific Capacity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Proportionality Constant?
In this formula, Proportionality Constant uses Area of the Well & Specific Capacity. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Proportionality Constant = Area of the Well*((1/Time Interval)*ln(Drawdown at the Start of Recuperation/Drawdown at a Time))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!