Radial Distance from Well 2 given Aquifer Constant Solution

STEP 0: Pre-Calculation Summary
Formula Used
Radial Distance at Observation Well 2 = Radial Distance at Observation Well 1*10^((2.72*Aquifer Constant*(Drawdown in well 1-Drawdown in well 2))/Discharge)
r2 = r1*10^((2.72*T*(s1-s2))/Q)
This formula uses 6 Variables
Variables Used
Radial Distance at Observation Well 2 - (Measured in Meter) - Radial Distance at Observation Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Radial Distance at Observation Well 1 - (Measured in Meter) - Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
Aquifer Constant - Aquifer Constant is also known as coefficient of transmissibility.
Drawdown in well 1 - (Measured in Meter) - Drawdown in well 1 is a peak-to-trough decline during a specific period for well 1.
Drawdown in well 2 - (Measured in Meter) - Drawdown in well 2 is a peak-to-trough decline during a specific period for well 2.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
STEP 1: Convert Input(s) to Base Unit
Radial Distance at Observation Well 1: 1.07 Meter --> 1.07 Meter No Conversion Required
Aquifer Constant: 24.67 --> No Conversion Required
Drawdown in well 1: 2.15 Meter --> 2.15 Meter No Conversion Required
Drawdown in well 2: 2.136 Meter --> 2.136 Meter No Conversion Required
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
r2 = r1*10^((2.72*T*(s1-s2))/Q) --> 1.07*10^((2.72*24.67*(2.15-2.136))/1.01)
Evaluating ... ...
r2 = 9.10995129132039
STEP 3: Convert Result to Output's Unit
9.10995129132039 Meter --> No Conversion Required
FINAL ANSWER
9.10995129132039 9.109951 Meter <-- Radial Distance at Observation Well 2
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

4 Radial Distance from Well And Thickness of Aquifer Calculators

Radial Distance from Well 1 given Aquifer Constant
Go Radial Distance at Observation Well 1 = Radial Distance at Observation Well 2/10^((2.72*Aquifer Constant*(Drawdown in well 1-Drawdown in well 2))/Discharge)
Radial Distance from Well 2 given Aquifer Constant
Go Radial Distance at Observation Well 2 = Radial Distance at Observation Well 1*10^((2.72*Aquifer Constant*(Drawdown in well 1-Drawdown in well 2))/Discharge)
Thickness of Aquifer from Impermeable Layer given Drawdown in Well 2
Go Thickness of aquifer = Depth of Water 2+Drawdown in well 2
Thickness of Aquifer from Impermeable Layer given Drawdown in Well 1
Go Thickness of aquifer = Depth of Water+Drawdown in well 1

Radial Distance from Well 2 given Aquifer Constant Formula

Radial Distance at Observation Well 2 = Radial Distance at Observation Well 1*10^((2.72*Aquifer Constant*(Drawdown in well 1-Drawdown in well 2))/Discharge)
r2 = r1*10^((2.72*T*(s1-s2))/Q)

What is Aquifer?

An aquifer is a body of rock and/or sediment that holds groundwater. Groundwater is the word used to describe precipitation that has infiltrated the soil beyond the surface and collected in empty spaces underground.

How to Calculate Radial Distance from Well 2 given Aquifer Constant?

Radial Distance from Well 2 given Aquifer Constant calculator uses Radial Distance at Observation Well 2 = Radial Distance at Observation Well 1*10^((2.72*Aquifer Constant*(Drawdown in well 1-Drawdown in well 2))/Discharge) to calculate the Radial Distance at Observation Well 2, The Radial Distance from Well 2 given Aquifer Constant is defined as the value of radial distance from 1st well when we have prior information of other parameters used. Radial Distance at Observation Well 2 is denoted by r2 symbol.

How to calculate Radial Distance from Well 2 given Aquifer Constant using this online calculator? To use this online calculator for Radial Distance from Well 2 given Aquifer Constant, enter Radial Distance at Observation Well 1 (r1), Aquifer Constant (T), Drawdown in well 1 (s1), Drawdown in well 2 (s2) & Discharge (Q) and hit the calculate button. Here is how the Radial Distance from Well 2 given Aquifer Constant calculation can be explained with given input values -> 42.56987 = 1.07*10^((2.72*24.67*(2.15-2.136))/1.01).

FAQ

What is Radial Distance from Well 2 given Aquifer Constant?
The Radial Distance from Well 2 given Aquifer Constant is defined as the value of radial distance from 1st well when we have prior information of other parameters used and is represented as r2 = r1*10^((2.72*T*(s1-s2))/Q) or Radial Distance at Observation Well 2 = Radial Distance at Observation Well 1*10^((2.72*Aquifer Constant*(Drawdown in well 1-Drawdown in well 2))/Discharge). Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used, Aquifer Constant is also known as coefficient of transmissibility, Drawdown in well 1 is a peak-to-trough decline during a specific period for well 1, Drawdown in well 2 is a peak-to-trough decline during a specific period for well 2 & Discharge is the rate of flow of a liquid.
How to calculate Radial Distance from Well 2 given Aquifer Constant?
The Radial Distance from Well 2 given Aquifer Constant is defined as the value of radial distance from 1st well when we have prior information of other parameters used is calculated using Radial Distance at Observation Well 2 = Radial Distance at Observation Well 1*10^((2.72*Aquifer Constant*(Drawdown in well 1-Drawdown in well 2))/Discharge). To calculate Radial Distance from Well 2 given Aquifer Constant, you need Radial Distance at Observation Well 1 (r1), Aquifer Constant (T), Drawdown in well 1 (s1), Drawdown in well 2 (s2) & Discharge (Q). With our tool, you need to enter the respective value for Radial Distance at Observation Well 1, Aquifer Constant, Drawdown in well 1, Drawdown in well 2 & Discharge and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!