Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)
R2 = r1*10^((2.72*Tenvi*(h2-h1))/Q0)
This formula uses 6 Variables
Variables Used
Radial Distance at Well 2 - (Measured in Meter) - Radial Distance at Well 2 is the value of radial distance from well 2 when we have prior information of other parameters used.
Radial Distance at Observation Well 1 - (Measured in Meter) - Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used.
Coefficient of Transmissibility - (Measured in Square Meter per Second) - Coefficient of transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer.
Depth of Water 2 - (Measured in Meter) - Depth of water 2 means the depth of the water in 2nd well.
Depth of Water 1 - (Measured in Meter) - Depth of water 1 is the depth of water in the 1st considered well.
Discharge at Time t=0 - (Measured in Cubic Meter per Second) - Discharge at Time t=0 is the rate of flow of a liquid that moves over a designated point over a fixed period.
STEP 1: Convert Input(s) to Base Unit
Radial Distance at Observation Well 1: 1.07 Meter --> 1.07 Meter No Conversion Required
Coefficient of Transmissibility: 1.5 Square Meter per Second --> 1.5 Square Meter per Second No Conversion Required
Depth of Water 2: 17.8644 Meter --> 17.8644 Meter No Conversion Required
Depth of Water 1: 17.85 Meter --> 17.85 Meter No Conversion Required
Discharge at Time t=0: 50 Cubic Meter per Second --> 50 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
R2 = r1*10^((2.72*Tenvi*(h2-h1))/Q0) --> 1.07*10^((2.72*1.5*(17.8644-17.85))/50)
Evaluating ... ...
R2 = 1.07289894362417
STEP 3: Convert Result to Output's Unit
1.07289894362417 Meter --> No Conversion Required
FINAL ANSWER
1.07289894362417 1.072899 Meter <-- Radial Distance at Well 2
(Calculation completed in 00.035 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

12 Radial Distance and Radius of well Calculators

Radius of Well given Discharge in Confined Aquifer
Go Radius of well = Radius of Influence/exp((2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Initial Aquifer Thickness-Depth of Water))/Discharge at Time t=0)
Radial Distance of Well 2 given Confined Aquifer Discharge
Go Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)
Radius of Well given Confined Aquifer Discharge
Go Radius of Well in Eviron. Engin. = Radius of Influence/(exp((2*pi*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown in Well)/Discharge))
Radial Distance of Well 1 given Confined Aquifer Discharge
Go Radial Distance 1 = Radial Distance at Observation Well 2/10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)
Radius of Well given Coefficient of Transmissibility
Go Radius of well = Radius of Influence/exp((2*pi*Coefficient of Transmissibility*(Initial Aquifer Thickness-Depth of Water))/Discharge at Time t=0)
Radius of Well for Discharge in Confined Aquifer with Base 10
Go Radius of well = Radius of Influence/(10^(2.72*Standard Coefficient of Permeability*Thickness of aquifer 1*(Initial Aquifer Thickness-Depth of Water))/Discharge)
Radius of Well given Confined Aquifer Discharge with Base 10
Go Radius of Well in Eviron. Engin. = Radius of Influence/(10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*Total Drawdown in Well)/Discharge))
Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge
Go Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)
Radius of Well given Drawdown at Well
Go Radius of Well in Well Hydraulics = Radius of Influence/(exp((2*pi*Coefficient of Transmissibility*Total Drawdown in Well)/Discharge))
Radial Distance of Well 1 given Coefficient of Transmissibility and Discharge
Go Radial Distance 1 = Radial Distance at Observation Well 2/10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)
Radius of Well given Coefficient of Transmissibility with Base 10
Go Radius of well = Radius of Influence/10^((2.72*Coefficient of Transmissibility*(Initial Aquifer Thickness-Depth of Water))/Discharge at Time t=0)
Radius of Well given Drawdown at Well with Base 10
Go Radius of Well in Well Hydraulics = Radius of Influence/(10^((2.72*Coefficient of Transmissibility*Total Drawdown in Well)/Discharge))

Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge Formula

Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)
R2 = r1*10^((2.72*Tenvi*(h2-h1))/Q0)

What is Coefficient of Transmissibility?

The coefficient of transmissibility. is defined as the rate of flow of water. in gallons per day through a vertical. strip of the aquifer 1 ft wide and ex- tending the full saturated thickness.

How to Calculate Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge?

Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge calculator uses Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0) to calculate the Radial Distance at Well 2, The Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge is defined as the value of radial distance from 2nd well when we have prior information of other parameters used. Radial Distance at Well 2 is denoted by R2 symbol.

How to calculate Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge using this online calculator? To use this online calculator for Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge, enter Radial Distance at Observation Well 1 (r1), Coefficient of Transmissibility (Tenvi), Depth of Water 2 (h2), Depth of Water 1 (h1) & Discharge at Time t=0 (Q0) and hit the calculate button. Here is how the Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge calculation can be explained with given input values -> 1.072899 = 1.07*10^((2.72*1.5*(17.8644-17.85))/50).

FAQ

What is Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge?
The Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge is defined as the value of radial distance from 2nd well when we have prior information of other parameters used and is represented as R2 = r1*10^((2.72*Tenvi*(h2-h1))/Q0) or Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0). Radial Distance at Observation Well 1 is the value of radial distance from well 1 when we have prior information of other parameters used, Coefficient of transmissibility is defined as the rate of flow of water in gallons per day through a vertical strip of the aquifer, Depth of water 2 means the depth of the water in 2nd well, Depth of water 1 is the depth of water in the 1st considered well & Discharge at Time t=0 is the rate of flow of a liquid that moves over a designated point over a fixed period.
How to calculate Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge?
The Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge is defined as the value of radial distance from 2nd well when we have prior information of other parameters used is calculated using Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Transmissibility*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0). To calculate Radial Distance of Well 2 given Coefficient of Transmissibility and Discharge, you need Radial Distance at Observation Well 1 (r1), Coefficient of Transmissibility (Tenvi), Depth of Water 2 (h2), Depth of Water 1 (h1) & Discharge at Time t=0 (Q0). With our tool, you need to enter the respective value for Radial Distance at Observation Well 1, Coefficient of Transmissibility, Depth of Water 2, Depth of Water 1 & Discharge at Time t=0 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Radial Distance at Well 2?
In this formula, Radial Distance at Well 2 uses Radial Distance at Observation Well 1, Coefficient of Transmissibility, Depth of Water 2, Depth of Water 1 & Discharge at Time t=0. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Radial Distance at Well 2 = Radial Distance at Observation Well 1*10^((2.72*Coefficient of Permeability in Well Hydraulics*Aquifer Thickness During Pumping*(Depth of Water 2-Depth of Water 1))/Discharge at Time t=0)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!