Resistance of Neutral Wire (Two-Phase Three-Wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Resistance of Neutral Wire = Resistance Overhead AC/sqrt(2)
Rneutral = R/sqrt(2)
This formula uses 1 Functions, 2 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Resistance of Neutral Wire - (Measured in Ohm) - Resistance of Neutral Wire is the resistance offered by the wire to the flow of current in the system.
Resistance Overhead AC - (Measured in Ohm) - Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
STEP 1: Convert Input(s) to Base Unit
Resistance Overhead AC: 0.0028 Ohm --> 0.0028 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rneutral = R/sqrt(2) --> 0.0028/sqrt(2)
Evaluating ... ...
Rneutral = 0.00197989898732233
STEP 3: Convert Result to Output's Unit
0.00197989898732233 Ohm --> No Conversion Required
FINAL ANSWER
0.00197989898732233 0.00198 Ohm <-- Resistance of Neutral Wire
(Calculation completed in 00.004 seconds)

Credits

Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verified by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has verified this Calculator and 100+ more calculators!

7 Resistance & Resistivity Calculators

Resistivity using Area of X-Section(Two-Phase Three-Wire OS)
Go Resistivity = (2*Area of Overhead AC Wire*(Maximum Voltage Overhead AC^2)*Line Losses*((cos(Phase Difference))^2))/((2+sqrt(2))*Length of Overhead AC Wire*(Power Transmitted^2))
Resistivity using Line Losses (Two-Phase Three-Wire OS)
Go Resistivity = 2*Line Losses*Area of Overhead AC Wire*(Maximum Voltage Overhead AC*cos(Phase Difference))^2/((2+sqrt(2))*(Power Transmitted)^2*Length of Overhead AC Wire)
Resistivity using Volume of Conductor Material (Two-Phase Three-Wire OS)
Go Resistivity = Volume of Conductor*Line Losses*(Maximum Voltage Overhead AC*(cos(Phase Difference)))^2/(((sqrt(2)+1)*Power Transmitted*Length of Overhead AC Wire)^2)
Resistivity using Resistance (Two-Phase Three-Wire OS)
Go Resistivity = Resistance Overhead AC*Area of Overhead AC Wire*sqrt(2)/(Length of Overhead AC Wire)
Resistance(Two-Phase Three-Wire OS)
Go Resistance Overhead AC = Resistivity*Length of Overhead AC Wire/Area of Overhead AC Wire
Resistance using Line Losses (Two-Phase Three-Wire OS)
Go Resistance Overhead AC = Line Losses/((2+sqrt(2))*(Current Overhead AC)^2)
Resistance of Neutral Wire (Two-Phase Three-Wire OS)
Go Resistance of Neutral Wire = Resistance Overhead AC/sqrt(2)

Resistance of Neutral Wire (Two-Phase Three-Wire OS) Formula

Resistance of Neutral Wire = Resistance Overhead AC/sqrt(2)
Rneutral = R/sqrt(2)

What is 2-phase 3-wire overhead system?

A 2-phase, 3-wire AC system has a middle conductor of the same cross-sectional area as the outer and supplies a load of 20 MW. The system is converted into 3-phase, 4-wire system by running a neutral wire. Calculate the new power which can be supplied if the voltage across the consumer terminal and percentage line losses remain the same.

How to Calculate Resistance of Neutral Wire (Two-Phase Three-Wire OS)?

Resistance of Neutral Wire (Two-Phase Three-Wire OS) calculator uses Resistance of Neutral Wire = Resistance Overhead AC/sqrt(2) to calculate the Resistance of Neutral Wire, The Resistance of Neutral Wire (two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit. Resistance of Neutral Wire is denoted by Rneutral symbol.

How to calculate Resistance of Neutral Wire (Two-Phase Three-Wire OS) using this online calculator? To use this online calculator for Resistance of Neutral Wire (Two-Phase Three-Wire OS), enter Resistance Overhead AC (R) and hit the calculate button. Here is how the Resistance of Neutral Wire (Two-Phase Three-Wire OS) calculation can be explained with given input values -> 0.00198 = 0.0028/sqrt(2).

FAQ

What is Resistance of Neutral Wire (Two-Phase Three-Wire OS)?
The Resistance of Neutral Wire (two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit and is represented as Rneutral = R/sqrt(2) or Resistance of Neutral Wire = Resistance Overhead AC/sqrt(2). Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
How to calculate Resistance of Neutral Wire (Two-Phase Three-Wire OS)?
The Resistance of Neutral Wire (two-phase three-wire OS) formula is defined as a measure of the opposition to current flow in an electrical circuit is calculated using Resistance of Neutral Wire = Resistance Overhead AC/sqrt(2). To calculate Resistance of Neutral Wire (Two-Phase Three-Wire OS), you need Resistance Overhead AC (R). With our tool, you need to enter the respective value for Resistance Overhead AC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!