Sensible Heat Gains per person = Sensible Heat Gain from people/(Number of people*Cooling Load Factor for people)
qs = QS/(n*CLF)
This formula uses 4 Variables
Variables Used
Sensible Heat Gains per person - (Measured in Watt) - Sensible heat gains per person is Heat gain from persons in air conditioned spaces.
Sensible Heat Gain from people - (Measured in Watt) - Sensible Heat Gain from people is increase in heat per person for the degree or type of activity in the space.
Number of people - Number of people is the count of people responsible for heat gain in space.
Cooling Load Factor for people - Cooling load factor for people is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation.
STEP 1: Convert Input(s) to Base Unit
Sensible Heat Gain from people: 840 Btu (th) per Hour --> 246.014999994036 Watt (Check conversion here)
Number of people: 70 --> No Conversion Required
Cooling Load Factor for people: 1.2 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
qs = QS/(n*CLF) --> 246.014999994036/(70*1.2)
Evaluating ... ...
qs = 2.928749999929
STEP 3: Convert Result to Output's Unit
2.928749999929 Watt -->9.99999999999999 Btu (th) per Hour (Check conversion here)
FINAL ANSWER
9.99999999999999 10 Btu (th) per Hour <-- Sensible Heat Gains per person
(Calculation completed in 00.004 seconds)

Credits

Created by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has created this Calculator and 100+ more calculators!
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

6 Sensible Cooling Loads Calculators

Sensible Cooling load from ventilation air
Go Sensible cooling loads from ventilation air = 1.1*Air ventilation rate in Cubic foot per minute*Temperature change between Outdoor and Inside air
Sensible Heat Gain per people using Sensible Heat Gain from people
Go Sensible Heat Gains per person = Sensible Heat Gain from people/(Number of people*Cooling Load Factor for people)
Sensible Heat Gain from people
Go Sensible Heat Gain from people = Sensible Heat Gains per person*Number of people*Cooling Load Factor for people
Sensible Cooling Load Heat Gain through Structure
Go Sensible Cooling Load = Overall Heat Transfer Coefficient*Surface Area*Cooling Load Temperature Difference
Sensible Cooling Load due to infiltrating air
Go Sensible Cooling Load = 1.1*Air Infiltration Rate into Room*Temperature change between Outdoor and Inside air
Sensible Cooling load due to Equipment
Go Sensible Cooling Load = Total Cooling Load/Latent Factor

Sensible Heat Gain per people using Sensible Heat Gain from people Formula

Sensible Heat Gains per person = Sensible Heat Gain from people/(Number of people*Cooling Load Factor for people)
qs = QS/(n*CLF)

What is sensible heat gain?

When an object is heated, its temperature rises as heat is added. The increase in heat is called sensible heat.

How to Calculate Sensible Heat Gain per people using Sensible Heat Gain from people?

Sensible Heat Gain per people using Sensible Heat Gain from people calculator uses Sensible Heat Gains per person = Sensible Heat Gain from people/(Number of people*Cooling Load Factor for people) to calculate the Sensible Heat Gains per person, The Sensible Heat Gain per people using Sensible Heat Gain from people formula is defined as Heat that results from an increase or decreases from persons in the amount of dryness held by the air, in air-conditioned spaces. Sensible Heat Gains per person is denoted by qs symbol.

How to calculate Sensible Heat Gain per people using Sensible Heat Gain from people using this online calculator? To use this online calculator for Sensible Heat Gain per people using Sensible Heat Gain from people, enter Sensible Heat Gain from people (QS), Number of people (n) & Cooling Load Factor for people (CLF) and hit the calculate button. Here is how the Sensible Heat Gain per people using Sensible Heat Gain from people calculation can be explained with given input values -> 34.14426 = 246.014999994036/(70*1.2).

FAQ

What is Sensible Heat Gain per people using Sensible Heat Gain from people?
The Sensible Heat Gain per people using Sensible Heat Gain from people formula is defined as Heat that results from an increase or decreases from persons in the amount of dryness held by the air, in air-conditioned spaces and is represented as qs = QS/(n*CLF) or Sensible Heat Gains per person = Sensible Heat Gain from people/(Number of people*Cooling Load Factor for people). Sensible Heat Gain from people is increase in heat per person for the degree or type of activity in the space, Number of people is the count of people responsible for heat gain in space & Cooling load factor for people is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation.
How to calculate Sensible Heat Gain per people using Sensible Heat Gain from people?
The Sensible Heat Gain per people using Sensible Heat Gain from people formula is defined as Heat that results from an increase or decreases from persons in the amount of dryness held by the air, in air-conditioned spaces is calculated using Sensible Heat Gains per person = Sensible Heat Gain from people/(Number of people*Cooling Load Factor for people). To calculate Sensible Heat Gain per people using Sensible Heat Gain from people, you need Sensible Heat Gain from people (QS), Number of people (n) & Cooling Load Factor for people (CLF). With our tool, you need to enter the respective value for Sensible Heat Gain from people, Number of people & Cooling Load Factor for people and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!