Sewer System Length given Total Infiltration to Sanitary Sewer Solution

STEP 0: Pre-Calculation Summary
Formula Used
Length = Infiltration/Actual Infiltration
L = I/F
This formula uses 3 Variables
Variables Used
Length - (Measured in Meter) - Length is the measurement or extent of something from end to end.
Infiltration - (Measured in Square Meter per Second) - Infiltration is the process by which water on the ground surface enters the soil. It is commonly used in both hydrology and soil sciences.
Actual Infiltration - (Measured in Cubic Meter per Second) - Actual Infiltration is the process of water entry into the soil through the earth's surface.
STEP 1: Convert Input(s) to Base Unit
Infiltration: 30 Square Meter per Second --> 30 Square Meter per Second No Conversion Required
Actual Infiltration: 90 Cubic Meter per Second --> 90 Cubic Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
L = I/F --> 30/90
Evaluating ... ...
L = 0.333333333333333
STEP 3: Convert Result to Output's Unit
0.333333333333333 Meter --> No Conversion Required
FINAL ANSWER
0.333333333333333 0.333333 Meter <-- Length
(Calculation completed in 00.004 seconds)

Credits

Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

10+ Sanitary system sewer design Calculators

Quantity of Sewage Produced Per Day given Sanitary Sewer System Flow Rate
Go Discharge = Sanitary system sewer flow rate/(Area*Population Density of Area)
Population Density given Sanitary Sewer System Flow Rate
Go Population Density of Area = Sanitary system sewer flow rate/(Area*Discharge)
Sanitary Sewer System Flow Rate
Go Sanitary system sewer flow rate = Area*Population Density of Area*Discharge
Manning's Formula for Conveyance Factor given Flow Rate through Pipe
Go Conveyance factor = Waste water flow/sqrt(Hydraulic Gradient)
Fire Demand for Cities of Less than 200,000 Population
Go Fire Demand = 1020*Population in Thousands^0.5*(1-0.01*(Population in Thousands^0.5))
Flow Rate through Pipe using Manning Formula
Go Waste water flow = Conveyance factor*(Hydraulic Gradient)^1/2
Manning's Formula for Pipe Slope given Flow Rate through Pipe
Go Hydraulic Gradient = (Waste water flow/Conveyance factor)^2
Sewer System Length given Total Infiltration to Sanitary Sewer
Go Length = Infiltration/Actual Infiltration
Infiltration given Total Infiltration to Sanitary Sewer
Go Infiltration = Actual Infiltration/Length
Total Infiltration to Sanitary sewer
Go Actual Infiltration = Infiltration*Length

Sewer System Length given Total Infiltration to Sanitary Sewer Formula

Length = Infiltration/Actual Infiltration
L = I/F

What is sanitary sewer?

The sanitary sewer is a system of underground pipes that carries sewage from bathrooms, sinks, kitchens, and other plumbing components to a wastewater treatment plant where it is filtered, treated and discharged.

How to Calculate Sewer System Length given Total Infiltration to Sanitary Sewer?

Sewer System Length given Total Infiltration to Sanitary Sewer calculator uses Length = Infiltration/Actual Infiltration to calculate the Length, The Sewer System Length given Total Infiltration to Sanitary Sewer is the total length of the sewer carrying the incoming sewage. Length is denoted by L symbol.

How to calculate Sewer System Length given Total Infiltration to Sanitary Sewer using this online calculator? To use this online calculator for Sewer System Length given Total Infiltration to Sanitary Sewer, enter Infiltration (I) & Actual Infiltration (F) and hit the calculate button. Here is how the Sewer System Length given Total Infiltration to Sanitary Sewer calculation can be explained with given input values -> 0.333333 = 30/90.

FAQ

What is Sewer System Length given Total Infiltration to Sanitary Sewer?
The Sewer System Length given Total Infiltration to Sanitary Sewer is the total length of the sewer carrying the incoming sewage and is represented as L = I/F or Length = Infiltration/Actual Infiltration. Infiltration is the process by which water on the ground surface enters the soil. It is commonly used in both hydrology and soil sciences & Actual Infiltration is the process of water entry into the soil through the earth's surface.
How to calculate Sewer System Length given Total Infiltration to Sanitary Sewer?
The Sewer System Length given Total Infiltration to Sanitary Sewer is the total length of the sewer carrying the incoming sewage is calculated using Length = Infiltration/Actual Infiltration. To calculate Sewer System Length given Total Infiltration to Sanitary Sewer, you need Infiltration (I) & Actual Infiltration (F). With our tool, you need to enter the respective value for Infiltration & Actual Infiltration and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!