Static Temperature of Fluid over Flat Plate Solution

STEP 0: Pre-Calculation Summary
Formula Used
Static Temperature = Temperature of wall in Kelvin/(Static density/Wall Density)
Tstatic = Tw/(ρe/ρw)
This formula uses 4 Variables
Variables Used
Static Temperature - (Measured in Kelvin) - The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing.
Temperature of wall in Kelvin - (Measured in Kelvin) - Temperature of wall in Kelvin is the wall temperature of the body under a flow.
Static density - (Measured in Kilogram per Cubic Meter) - Static density, is the density of the fluid when its not moving, or the density of fluid if we are moving relative to the fluid.
Wall Density - (Measured in Kilogram per Cubic Meter) - Wall Density is the variable considered under turbulent conditions as the density varies near the wall under high viscous flows.
STEP 1: Convert Input(s) to Base Unit
Temperature of wall in Kelvin: 357 Kelvin --> 357 Kelvin No Conversion Required
Static density: 100 Kilogram per Cubic Meter --> 100 Kilogram per Cubic Meter No Conversion Required
Wall Density: 14 Kilogram per Cubic Meter --> 14 Kilogram per Cubic Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Tstatic = Tw/(ρew) --> 357/(100/14)
Evaluating ... ...
Tstatic = 49.98
STEP 3: Convert Result to Output's Unit
49.98 Kelvin --> No Conversion Required
FINAL ANSWER
49.98 Kelvin <-- Static Temperature
(Calculation completed in 00.004 seconds)

Credits

Created by Sanjay Krishna
Amrita School of Engineering (ASE), Vallikavu
Sanjay Krishna has created this Calculator and 300+ more calculators!
Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology (VNRVJIET), Hyderabad
Sai Venkata Phanindra Chary Arendra has verified this Calculator and 300+ more calculators!

6 Static Parameters for Hypersonic Flow Calculators

Static Temperature over Flat Plate under Viscous, Very High Mach Flow
Go Static Temperature = Temperature of wall in Kelvin/(((Specific Heat Ratio-1)/2)*Mach Number^2)
Static Temperature of Plate using Wall Viscosity
Go Static Temperature = Temperature of wall in Kelvin/(Wall Viscosity/Static Viscosity)
Static Temperature over Flat Plate using Static Mach Number
Go Static Temperature = Wall Temperature/((1+(Specific Heat Ratio-1)/2)*Mach Number^2)
Static Temperature of Fluid over Flat Plate
Go Static Temperature = Temperature of wall in Kelvin/(Static density/Wall Density)
Static Viscosity using Wall Temperature and Static Temperature
Go Static Viscosity = Wall Viscosity/(Wall Temperature/Static Temperature)
Static Density of Fluid over Flat Plate
Go Static density = Wall Temperature/Static Temperature*Wall Density

Static Temperature of Fluid over Flat Plate Formula

Static Temperature = Temperature of wall in Kelvin/(Static density/Wall Density)
Tstatic = Tw/(ρe/ρw)

What is density?

Density is a measure of mass per volume. The average density of an object equals its total mass divided by its total volume.

How to Calculate Static Temperature of Fluid over Flat Plate?

Static Temperature of Fluid over Flat Plate calculator uses Static Temperature = Temperature of wall in Kelvin/(Static density/Wall Density) to calculate the Static Temperature, The Static temperature of fluid over flat plate formula is defined as the ratio of static temperature and to the ratio of static density to wall density. Static Temperature is denoted by Tstatic symbol.

How to calculate Static Temperature of Fluid over Flat Plate using this online calculator? To use this online calculator for Static Temperature of Fluid over Flat Plate, enter Temperature of wall in Kelvin (Tw), Static density e) & Wall Density w) and hit the calculate button. Here is how the Static Temperature of Fluid over Flat Plate calculation can be explained with given input values -> 49.98 = 357/(100/14).

FAQ

What is Static Temperature of Fluid over Flat Plate?
The Static temperature of fluid over flat plate formula is defined as the ratio of static temperature and to the ratio of static density to wall density and is represented as Tstatic = Tw/(ρew) or Static Temperature = Temperature of wall in Kelvin/(Static density/Wall Density). Temperature of wall in Kelvin is the wall temperature of the body under a flow, Static density, is the density of the fluid when its not moving, or the density of fluid if we are moving relative to the fluid & Wall Density is the variable considered under turbulent conditions as the density varies near the wall under high viscous flows.
How to calculate Static Temperature of Fluid over Flat Plate?
The Static temperature of fluid over flat plate formula is defined as the ratio of static temperature and to the ratio of static density to wall density is calculated using Static Temperature = Temperature of wall in Kelvin/(Static density/Wall Density). To calculate Static Temperature of Fluid over Flat Plate, you need Temperature of wall in Kelvin (Tw), Static density e) & Wall Density w). With our tool, you need to enter the respective value for Temperature of wall in Kelvin, Static density & Wall Density and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Static Temperature?
In this formula, Static Temperature uses Temperature of wall in Kelvin, Static density & Wall Density. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Static Temperature = Wall Temperature/((1+(Specific Heat Ratio-1)/2)*Mach Number^2)
  • Static Temperature = Temperature of wall in Kelvin/(((Specific Heat Ratio-1)/2)*Mach Number^2)
  • Static Temperature = Temperature of wall in Kelvin/(Wall Viscosity/Static Viscosity)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!