Temperature given Oxygen Transfer Capacity Solution

STEP 0: Pre-Calculation Summary
Formula Used
Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor)),1.024)+20
T = log(((N*9.17)/(Ns*(DS-DL)*f)),1.024)+20
This formula uses 1 Functions, 6 Variables
Functions Used
log - Logarithmic function is an inverse function to exponentiation., log(Base, Number)
Variables Used
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred under field condition.
Oxygen transfer capacity - (Measured in Kilogram per Second per Watt) - Oxygen transfer capacity under standard conditions.
Dissolved oxygen saturation - (Measured in Kilogram per Cubic Meter) - Dissolved oxygen saturation value for sewage at operating temperature.
Operation dissolved oxygen - (Measured in Kilogram per Cubic Meter) - Operation dissolved oxygen level in aeration tank.
Correction Factor - Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
STEP 1: Convert Input(s) to Base Unit
Oxygen Transferred: 3 Kilogram per Hour per Kilowatt --> 8.33333333333333E-07 Kilogram per Second per Watt (Check conversion here)
Oxygen transfer capacity: 2 Kilogram per Hour per Kilowatt --> 5.55555555555556E-07 Kilogram per Second per Watt (Check conversion here)
Dissolved oxygen saturation: 3 Milligram per Liter --> 0.003 Kilogram per Cubic Meter (Check conversion here)
Operation dissolved oxygen: 2 Milligram per Liter --> 0.002 Kilogram per Cubic Meter (Check conversion here)
Correction Factor: 0.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
T = log(((N*9.17)/(Ns*(DS-DL)*f)),1.024)+20 --> log(((8.33333333333333E-07*9.17)/(5.55555555555556E-07*(0.003-0.002)*0.5)),1.024)+20
Evaluating ... ...
T = 20.0023200762408
STEP 3: Convert Result to Output's Unit
20.0023200762408 Kelvin --> No Conversion Required
FINAL ANSWER
20.0023200762408 20.00232 Kelvin <-- Temperature
(Calculation completed in 00.020 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

4 Temperature Requirements in Aeration Tank Calculators

Temperature given Oxygen Transfer Capacity
Go Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor)),1.024)+20
Temperature given Difference between Saturation D.O and Operation D.O
Go Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor)),1.024)+20
Temperature when Correction Factor is 0.85
Go Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.85)),1.024)+20
Temperature when Correction Factor is 0.8
Go Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.8)),1.024)+20

Temperature given Oxygen Transfer Capacity Formula

Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor)),1.024)+20
T = log(((N*9.17)/(Ns*(DS-DL)*f)),1.024)+20

What is aeration tank ?

Aeration in an activated sludge process is based on pumping air into a tank, which promotes the microbial growth in the wastewater. The microbes feed on the organic material, forming flocks which can easily settle out.

How to Calculate Temperature given Oxygen Transfer Capacity?

Temperature given Oxygen Transfer Capacity calculator uses Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor)),1.024)+20 to calculate the Temperature, Temperature given Oxygen Transfer Capacity calculates temperature when we have prior information of other parameters used. Temperature is denoted by T symbol.

How to calculate Temperature given Oxygen Transfer Capacity using this online calculator? To use this online calculator for Temperature given Oxygen Transfer Capacity, enter Oxygen Transferred (N), Oxygen transfer capacity (Ns), Dissolved oxygen saturation (DS), Operation dissolved oxygen (DL) & Correction Factor (f) and hit the calculate button. Here is how the Temperature given Oxygen Transfer Capacity calculation can be explained with given input values -> 20.00232 = log(((8.33333333333333E-07*9.17)/(5.55555555555556E-07*(0.003-0.002)*0.5)),1.024)+20.

FAQ

What is Temperature given Oxygen Transfer Capacity?
Temperature given Oxygen Transfer Capacity calculates temperature when we have prior information of other parameters used and is represented as T = log(((N*9.17)/(Ns*(DS-DL)*f)),1.024)+20 or Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor)),1.024)+20. Oxygen Transferred under field condition, Oxygen transfer capacity under standard conditions, Dissolved oxygen saturation value for sewage at operating temperature, Operation dissolved oxygen level in aeration tank & Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
How to calculate Temperature given Oxygen Transfer Capacity?
Temperature given Oxygen Transfer Capacity calculates temperature when we have prior information of other parameters used is calculated using Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*Correction Factor)),1.024)+20. To calculate Temperature given Oxygen Transfer Capacity, you need Oxygen Transferred (N), Oxygen transfer capacity (Ns), Dissolved oxygen saturation (DS), Operation dissolved oxygen (DL) & Correction Factor (f). With our tool, you need to enter the respective value for Oxygen Transferred, Oxygen transfer capacity, Dissolved oxygen saturation, Operation dissolved oxygen & Correction Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Temperature?
In this formula, Temperature uses Oxygen Transferred, Oxygen transfer capacity, Dissolved oxygen saturation, Operation dissolved oxygen & Correction Factor. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*Difference between saturation DO and operation DO*Correction Factor)),1.024)+20
  • Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.8)),1.024)+20
  • Temperature = log(((Oxygen Transferred*9.17)/(Oxygen transfer capacity*(Dissolved oxygen saturation-Operation dissolved oxygen)*0.85)),1.024)+20
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!