Total Volume of Mobile Phase within Column given Retention Factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Void Volume = Retention Volume/(Retention Factor+1)
V0 = VR/(Rf+1)
This formula uses 3 Variables
Variables Used
Void Volume - (Measured in Cubic Meter) - Void Volume is the volume of mobile phase in a column.
Retention Volume - (Measured in Cubic Meter) - The Retention Volume is defined as the volume of the mobile phase required to elute the solute from the column.
Retention Factor - Retention Factor is defined as the ratio of the distance traveled by the center of a spot to the distance traveled by the solvent front.
STEP 1: Convert Input(s) to Base Unit
Retention Volume: 11.2 Liter --> 0.0112 Cubic Meter (Check conversion here)
Retention Factor: 10 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V0 = VR/(Rf+1) --> 0.0112/(10+1)
Evaluating ... ...
V0 = 0.00101818181818182
STEP 3: Convert Result to Output's Unit
0.00101818181818182 Cubic Meter -->1018.18181818182 Milliliter (Check conversion here)
FINAL ANSWER
1018.18181818182 1018.182 Milliliter <-- Void Volume
(Calculation completed in 00.004 seconds)

Credits

Created by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has created this Calculator and 200+ more calculators!
Verified by Pratibha
Amity Institute Of Applied Sciences (AIAS, Amity University), Noida, India
Pratibha has verified this Calculator and 50+ more calculators!

17 Osmolality Calculators

Peak Resolution in Chromatography
Go Peak Resolution = (Retention Volume of Molecule 2-Retention Volume of Molecule 1)/((Width of Chromatographic Peak of Molecule 1+Widths of Chromatographic Peak of Molecule 2)/2)
Blood Urea Nitrogen using Calculated Serum Osmolality
Go Blood Urea Nitrogen = 2.8*((Calculated Serum Osmolality)-(2*Serum Sodium)-(Serum Glucose/18))
Serum Glucose using Calculated Serum Osmolality
Go Serum Glucose = 18*((Calculated Serum Osmolality)-(2*Serum Sodium)-(Blood Urea Nitrogen/2.8))
Serum Sodium using Calculated Serum Osmolality
Go Serum Sodium = ((Calculated Serum Osmolality)-(Serum Glucose/18)-(Blood Urea Nitrogen/2.8))/2
Calculated Serum Osmolality
Go Calculated Serum Osmolality = (2*Serum Sodium)+(Serum Glucose/18)+(Blood Urea Nitrogen/2.8)
Width of Chromatographic Peak using Column Efficiency
Go Width of Chromatographic Peak = Retention Volume/(sqrt(Column Efficiency/16))
Retention Volume using Column Efficiency
Go Retention Volume = Width of Chromatographic Peak*(sqrt(Column Efficiency/16))
Column Efficiency in Chromatography
Go Column Efficiency = 16*((Retention Volume/ Width of Chromatographic Peak)^2)
Increase of Splicing Potential by Wild-type Sequence
Go Splicing Potential = log10(Weight Factor for Increase of Splicing Potential)
Calculated Serum Osmolality using Osmolar Gap
Go Calculated Serum Osmolality = Measured Osmolality-Osmolar Gap
Measured Osmolality using Osmolar Gap
Go Measured Osmolality = Osmolar Gap+Calculated Serum Osmolality
Osmolar Gap
Go Osmolar Gap = Measured Osmolality-Calculated Serum Osmolality
Total Volume of Mobile Phase within Column given Retention Factor
Go Void Volume = Retention Volume/(Retention Factor+1)
Retention Volume using Retention Factor
Go Retention Volume = Void Volume*(Retention Factor+1)
Decrease of Splicing Potential by Mutant Sequence
Go Splicing Potential = -log10(Weight Factor)
Plasma Osmolality
Go Plasma Osmolality = (2*Sodium Concentration in Plasma)
Plasma Concentration using Plasma Osmolality
Go Sodium Concentration in Plasma = Plasma Osmolality/2

Total Volume of Mobile Phase within Column given Retention Factor Formula

Void Volume = Retention Volume/(Retention Factor+1)
V0 = VR/(Rf+1)

What is Column Chromatography?

Column chromatography separates substances based on differential adsorption of compounds to the adsorbent as the compounds move through the column at different rates which allow them to get separated in fractions. This technique can be used on a small scale as well as large scale to purify materials that can be used in future experiments. This method is a type of adsorption chromatography technique.

How to Calculate Total Volume of Mobile Phase within Column given Retention Factor?

Total Volume of Mobile Phase within Column given Retention Factor calculator uses Void Volume = Retention Volume/(Retention Factor+1) to calculate the Void Volume, The Total Volume of Mobile Phase within Column given Retention Factor formula in column chromatography is defined as the volume of the mobile phase is the total bed volume of the column minus the volume occupied by the support particles. Void Volume is denoted by V0 symbol.

How to calculate Total Volume of Mobile Phase within Column given Retention Factor using this online calculator? To use this online calculator for Total Volume of Mobile Phase within Column given Retention Factor, enter Retention Volume (VR) & Retention Factor (Rf) and hit the calculate button. Here is how the Total Volume of Mobile Phase within Column given Retention Factor calculation can be explained with given input values -> 1E+9 = 0.0112/(10+1).

FAQ

What is Total Volume of Mobile Phase within Column given Retention Factor?
The Total Volume of Mobile Phase within Column given Retention Factor formula in column chromatography is defined as the volume of the mobile phase is the total bed volume of the column minus the volume occupied by the support particles and is represented as V0 = VR/(Rf+1) or Void Volume = Retention Volume/(Retention Factor+1). The Retention Volume is defined as the volume of the mobile phase required to elute the solute from the column & Retention Factor is defined as the ratio of the distance traveled by the center of a spot to the distance traveled by the solvent front.
How to calculate Total Volume of Mobile Phase within Column given Retention Factor?
The Total Volume of Mobile Phase within Column given Retention Factor formula in column chromatography is defined as the volume of the mobile phase is the total bed volume of the column minus the volume occupied by the support particles is calculated using Void Volume = Retention Volume/(Retention Factor+1). To calculate Total Volume of Mobile Phase within Column given Retention Factor, you need Retention Volume (VR) & Retention Factor (Rf). With our tool, you need to enter the respective value for Retention Volume & Retention Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!