Transmissibility when Coefficient of Permeability is Considered Solution

STEP 0: Pre-Calculation Summary
Formula Used
Transmissivity = Coefficient of Permeability at the temperature*Aquifer Thickness
τ = K*b
This formula uses 3 Variables
Variables Used
Transmissivity - (Measured in Square Meter per Second) - Transmissivity describes the ability of the to transmit groundwater throughout its entire saturated thickness.
Coefficient of Permeability at the temperature - (Measured in Meter per Second) - The coefficient of Permeability at the temperature describes how easily a liquid will move through the porous medium.
Aquifer Thickness - (Measured in Meter) - Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
STEP 1: Convert Input(s) to Base Unit
Coefficient of Permeability at the temperature: 6 Centimeter per Second --> 0.06 Meter per Second (Check conversion here)
Aquifer Thickness: 15 Meter --> 15 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
τ = K*b --> 0.06*15
Evaluating ... ...
τ = 0.9
STEP 3: Convert Result to Output's Unit
0.9 Square Meter per Second --> No Conversion Required
FINAL ANSWER
0.9 Square Meter per Second <-- Transmissivity
(Calculation completed in 00.004 seconds)

Credits

Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

6 Transmissivity of Aquifer Calculators

Transmissivity given Discharge Quantity
Go Transmissivity = (Total Water Volume/Aquifer Thickness)*(Distance Between the Points/Change in Head Between the Points)
Quantity of water for transmissivity
Go Total Water Volume = Transmissivity*Aquifer Thickness*Hydraulic Gradient
Transmissibility when Coefficient of Permeability is Considered
Go Transmissivity = Coefficient of Permeability at the temperature*Aquifer Thickness
Unit dimension of aquifer about transmissivity
Go Aquifer Thickness = Transmissivity/Coefficient of Permeability at the temperature
Transmissivity of aquifer when equivalent permeability is considered
Go Transmissivity = Equivalent Permeability*Aquifer Thickness
Aquifer thickness when transmissivity of aquifer is considered
Go Aquifer Thickness = Transmissivity/Equivalent Permeability

Transmissibility when Coefficient of Permeability is Considered Formula

Transmissivity = Coefficient of Permeability at the temperature*Aquifer Thickness
τ = K*b

What is Aquifer Transmissivity?

Transmissivity describes the ability of the aquifer to transmit groundwater throughout its entire saturated thickness. Transmissivity is measured as the rate at which groundwater can flow through an aquifer section of unit width under a unit hydraulic gradient.

How to Calculate Transmissibility when Coefficient of Permeability is Considered?

Transmissibility when Coefficient of Permeability is Considered calculator uses Transmissivity = Coefficient of Permeability at the temperature*Aquifer Thickness to calculate the Transmissivity, The Transmissibility when Coefficient of Permeability is Considered (or transmissivity) is a property closely related to hydraulic conductivity that describes the capacity of a specific water‐bearing unit of a given thickness, such as an aquifer, to transmit water. Transmissivity is denoted by τ symbol.

How to calculate Transmissibility when Coefficient of Permeability is Considered using this online calculator? To use this online calculator for Transmissibility when Coefficient of Permeability is Considered, enter Coefficient of Permeability at the temperature (K) & Aquifer Thickness (b) and hit the calculate button. Here is how the Transmissibility when Coefficient of Permeability is Considered calculation can be explained with given input values -> 0.9 = 0.06*15.

FAQ

What is Transmissibility when Coefficient of Permeability is Considered?
The Transmissibility when Coefficient of Permeability is Considered (or transmissivity) is a property closely related to hydraulic conductivity that describes the capacity of a specific water‐bearing unit of a given thickness, such as an aquifer, to transmit water and is represented as τ = K*b or Transmissivity = Coefficient of Permeability at the temperature*Aquifer Thickness. The coefficient of Permeability at the temperature describes how easily a liquid will move through the porous medium & Aquifer Thickness (at Midpoint between Equipotential lines) or otherwise is the thickness of aquifer in which the pore spaces of rock forming the aquifer may or may not be with water.
How to calculate Transmissibility when Coefficient of Permeability is Considered?
The Transmissibility when Coefficient of Permeability is Considered (or transmissivity) is a property closely related to hydraulic conductivity that describes the capacity of a specific water‐bearing unit of a given thickness, such as an aquifer, to transmit water is calculated using Transmissivity = Coefficient of Permeability at the temperature*Aquifer Thickness. To calculate Transmissibility when Coefficient of Permeability is Considered, you need Coefficient of Permeability at the temperature (K) & Aquifer Thickness (b). With our tool, you need to enter the respective value for Coefficient of Permeability at the temperature & Aquifer Thickness and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Transmissivity?
In this formula, Transmissivity uses Coefficient of Permeability at the temperature & Aquifer Thickness. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Transmissivity = (Total Water Volume/Aquifer Thickness)*(Distance Between the Points/Change in Head Between the Points)
  • Transmissivity = Equivalent Permeability*Aquifer Thickness
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!