Secondary Voltage greater than Capacitor Voltage in Potential Divider Solution

STEP 0: Pre-Calculation Summary
Formula Used
Voltage Secondary = (Capacitance 1+Capacitance 2)*Meter Voltage/Capacitance 1
Vs = (C1+C2)*V/C1
This formula uses 4 Variables
Variables Used
Voltage Secondary - (Measured in Volt) - Voltage Secondary is the voltage in the secondary coil.
Capacitance 1 - (Measured in Farad) - Capacitance 1 is the value of the first capacitor in the network.
Capacitance 2 - (Measured in Farad) - Capacitance 2 is the value of the second capacitor in the network.
Meter Voltage - (Measured in Volt) - Meter Voltage is the amount of potential difference across two ends of the meter.
STEP 1: Convert Input(s) to Base Unit
Capacitance 1: 1.2 Farad --> 1.2 Farad No Conversion Required
Capacitance 2: 1.5 Farad --> 1.5 Farad No Conversion Required
Meter Voltage: 2.51 Volt --> 2.51 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vs = (C1+C2)*V/C1 --> (1.2+1.5)*2.51/1.2
Evaluating ... ...
Vs = 5.6475
STEP 3: Convert Result to Output's Unit
5.6475 Volt --> No Conversion Required
FINAL ANSWER
5.6475 Volt <-- Voltage Secondary
(Calculation completed in 00.004 seconds)

Credits

Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

5 High Voltage Calculators

Secondary Voltage in Potential Divider
Go Voltage Secondary = (Capacitance 1+Capacitance 2+Capacitance of Voltmeter)*Meter Voltage/Capacitance 1
Secondary Voltage greater than Capacitor Voltage in Potential Divider
Go Voltage Secondary = (Capacitance 1+Capacitance 2)*Meter Voltage/Capacitance 1
Voltage of Secondary Coil in Transformer Ratio Method
Go Voltage Secondary = Number of Turns in Secondary Winding*Voltage Primary/Number of Turns in Primary Winding
Voltage in Ryall Crest Voltmeter
Go Peak Value = Voltage Striking*(Capacitance 1+Capacitance 2)/Capacitance 2
Turns Ratio in Transformer Ratio Method
Go Turns Ratio = Number of Turns in Secondary Winding/Number of Turns in Primary Winding

Secondary Voltage greater than Capacitor Voltage in Potential Divider Formula

Voltage Secondary = (Capacitance 1+Capacitance 2)*Meter Voltage/Capacitance 1
Vs = (C1+C2)*V/C1

What are the advantages of a capacitance potential divider?

It is easy to construct, is free from heating effects as well as stray capacitance and magnetic effects.

How to Calculate Secondary Voltage greater than Capacitor Voltage in Potential Divider?

Secondary Voltage greater than Capacitor Voltage in Potential Divider calculator uses Voltage Secondary = (Capacitance 1+Capacitance 2)*Meter Voltage/Capacitance 1 to calculate the Voltage Secondary, The Secondary Voltage greater than Capacitor Voltage in Potential Divider formula is the value of the voltage in the secondary coil for a capacitance potential divider setup, when C2 >> Cv. Voltage Secondary is denoted by Vs symbol.

How to calculate Secondary Voltage greater than Capacitor Voltage in Potential Divider using this online calculator? To use this online calculator for Secondary Voltage greater than Capacitor Voltage in Potential Divider, enter Capacitance 1 (C1), Capacitance 2 (C2) & Meter Voltage (V) and hit the calculate button. Here is how the Secondary Voltage greater than Capacitor Voltage in Potential Divider calculation can be explained with given input values -> 5.6475 = (1.2+1.5)*2.51/1.2.

FAQ

What is Secondary Voltage greater than Capacitor Voltage in Potential Divider?
The Secondary Voltage greater than Capacitor Voltage in Potential Divider formula is the value of the voltage in the secondary coil for a capacitance potential divider setup, when C2 >> Cv and is represented as Vs = (C1+C2)*V/C1 or Voltage Secondary = (Capacitance 1+Capacitance 2)*Meter Voltage/Capacitance 1. Capacitance 1 is the value of the first capacitor in the network, Capacitance 2 is the value of the second capacitor in the network & Meter Voltage is the amount of potential difference across two ends of the meter.
How to calculate Secondary Voltage greater than Capacitor Voltage in Potential Divider?
The Secondary Voltage greater than Capacitor Voltage in Potential Divider formula is the value of the voltage in the secondary coil for a capacitance potential divider setup, when C2 >> Cv is calculated using Voltage Secondary = (Capacitance 1+Capacitance 2)*Meter Voltage/Capacitance 1. To calculate Secondary Voltage greater than Capacitor Voltage in Potential Divider, you need Capacitance 1 (C1), Capacitance 2 (C2) & Meter Voltage (V). With our tool, you need to enter the respective value for Capacitance 1, Capacitance 2 & Meter Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Voltage Secondary?
In this formula, Voltage Secondary uses Capacitance 1, Capacitance 2 & Meter Voltage. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Voltage Secondary = (Capacitance 1+Capacitance 2+Capacitance of Voltmeter)*Meter Voltage/Capacitance 1
  • Voltage Secondary = Number of Turns in Secondary Winding*Voltage Primary/Number of Turns in Primary Winding
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!