Wall Temperature of Plate using Wall Viscosity Solution

STEP 0: Pre-Calculation Summary
Formula Used
Temperature of wall in Kelvin = Static Temperature*Wall Viscosity/Static Viscosity
Tw = Tstatic*μw/μe
This formula uses 4 Variables
Variables Used
Temperature of wall in Kelvin - (Measured in Kelvin) - Temperature of wall in Kelvin is the wall temperature of the body under a flow.
Static Temperature - (Measured in Kelvin) - The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing.
Wall Viscosity - (Measured in Pascal Second) - Wall viscosity is the viscosity of fluid in near wall during the turbulent flow.
Static Viscosity - (Measured in Pascal Second) - Static viscosity, is the viscosity of continuous flow, viscosity measures the ratio of the viscous force to the inertial force on the fluid.
STEP 1: Convert Input(s) to Base Unit
Static Temperature: 350 Kelvin --> 350 Kelvin No Conversion Required
Wall Viscosity: 0.1 Poise --> 0.01 Pascal Second (Check conversion here)
Static Viscosity: 11.2 Poise --> 1.12 Pascal Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Tw = Tstaticw/μe --> 350*0.01/1.12
Evaluating ... ...
Tw = 3.125
STEP 3: Convert Result to Output's Unit
3.125 Kelvin --> No Conversion Required
FINAL ANSWER
3.125 Kelvin <-- Temperature of wall in Kelvin
(Calculation completed in 00.004 seconds)

Credits

Created by Sanjay Krishna
Amrita School of Engineering (ASE), Vallikavu
Sanjay Krishna has created this Calculator and 300+ more calculators!
Vallurupalli Nageswara Rao Vignana Jyothi Institute of Engineering and Technology (VNRVJIET), Hyderabad
Sai Venkata Phanindra Chary Arendra has verified this Calculator and 300+ more calculators!

4 Wall Temperature Calculators

Wall Temperature of Plate using Wall Viscosity
Go Temperature of wall in Kelvin = Static Temperature*Wall Viscosity/Static Viscosity
Wall Temperature over Flat Plate using Static Mach Number
Go Wall Temperature = Static Temperature*Mach Number^2*(1+(Specific Heat Ratio-1)/2)
Wall Temperature over Flat Plate under Viscous, Very High Mach Flow
Go Wall Temperature = Static Temperature*((Specific Heat Ratio-1)/2)*Mach Number^2
Wall Temperature of Fluid over Flat Plate
Go Temperature of wall in Kelvin = Static density/Wall Density*Static Temperature

Wall Temperature of Plate using Wall Viscosity Formula

Temperature of wall in Kelvin = Static Temperature*Wall Viscosity/Static Viscosity
Tw = Tstatic*μw/μe

What is Viscosity ?

Viscosity is a measure of a fluid's resistance to flow. It describes the internal friction of a moving fluid. A fluid with large viscosity resists motion because its molecular makeup gives it a lot of internal friction.

How to Calculate Wall Temperature of Plate using Wall Viscosity?

Wall Temperature of Plate using Wall Viscosity calculator uses Temperature of wall in Kelvin = Static Temperature*Wall Viscosity/Static Viscosity to calculate the Temperature of wall in Kelvin, The Wall temperature of plate using wall viscosity formula is defined as the function of wall viscosity, Static viscosity, and static temperature. Temperature of wall in Kelvin is denoted by Tw symbol.

How to calculate Wall Temperature of Plate using Wall Viscosity using this online calculator? To use this online calculator for Wall Temperature of Plate using Wall Viscosity, enter Static Temperature (Tstatic), Wall Viscosity w) & Static Viscosity (μe) and hit the calculate button. Here is how the Wall Temperature of Plate using Wall Viscosity calculation can be explained with given input values -> 3.125 = 350*0.01/1.12.

FAQ

What is Wall Temperature of Plate using Wall Viscosity?
The Wall temperature of plate using wall viscosity formula is defined as the function of wall viscosity, Static viscosity, and static temperature and is represented as Tw = Tstaticw/μe or Temperature of wall in Kelvin = Static Temperature*Wall Viscosity/Static Viscosity. The Static Temperature is defined as the temperature of the gas if it had no ordered motion and was not flowing, Wall viscosity is the viscosity of fluid in near wall during the turbulent flow & Static viscosity, is the viscosity of continuous flow, viscosity measures the ratio of the viscous force to the inertial force on the fluid.
How to calculate Wall Temperature of Plate using Wall Viscosity?
The Wall temperature of plate using wall viscosity formula is defined as the function of wall viscosity, Static viscosity, and static temperature is calculated using Temperature of wall in Kelvin = Static Temperature*Wall Viscosity/Static Viscosity. To calculate Wall Temperature of Plate using Wall Viscosity, you need Static Temperature (Tstatic), Wall Viscosity w) & Static Viscosity (μe). With our tool, you need to enter the respective value for Static Temperature, Wall Viscosity & Static Viscosity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Temperature of wall in Kelvin?
In this formula, Temperature of wall in Kelvin uses Static Temperature, Wall Viscosity & Static Viscosity. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Temperature of wall in Kelvin = Static density/Wall Density*Static Temperature
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!