Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water Solution

STEP 0: Pre-Calculation Summary
Formula Used
Water Hammer Pressure In Environmental Eng. = (Ratio of Velocities*Bulk Modulus of Water)
Pw = (VR*Kw)
This formula uses 3 Variables
Variables Used
Water Hammer Pressure In Environmental Eng. - (Measured in Pascal) - Water Hammer Pressure In Environmental Eng. is defined as pressure surge caused by a rapid change in flow velocity in the pipeline.
Ratio of Velocities - Ratio of Velocities is the ratio of velocity of water to velocity of sound in water.
Bulk Modulus of Water - (Measured in Pascal) - Bulk Modulus of Water is defined as the proportion of volumetric stress linked to the volumetric strain of definite material, although the deformation of the material is within the elastic limit.
STEP 1: Convert Input(s) to Base Unit
Ratio of Velocities: 0.9 --> No Conversion Required
Bulk Modulus of Water: 2 Megapascal --> 2000000 Pascal (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pw = (VR*Kw) --> (0.9*2000000)
Evaluating ... ...
Pw = 1800000
STEP 3: Convert Result to Output's Unit
1800000 Pascal -->1.8 Megapascal (Check conversion here)
FINAL ANSWER
1.8 Megapascal <-- Water Hammer Pressure In Environmental Eng.
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

10+ Water Hammer Calculators

Bulk Modulus of Elasticity of Water given Water Hammer Pressure
Go Bulk Modulus of Water = (Velocity of Sound in Water*Water Hammer Pressure In Environmental Eng.)/Flow Velocity of Fluid
Velocity of Sound in Water given Water Hammer Pressure
Go Velocity of Sound in Water = (Flow Velocity of Fluid*Bulk Modulus of Water)/Water Hammer Pressure In Environmental Eng.
Initial Velocity of Water given Water Hammer Pressure
Go Flow Velocity of Fluid = (Water Hammer Pressure In Environmental Eng.*Velocity of Sound in Water)/Bulk Modulus of Water
Water Hammer Pressure
Go Water Hammer Pressure In Environmental Eng. = (Flow Velocity of Fluid*Bulk Modulus of Water)/Velocity of Sound in Water
Bulk Modulus of Elasticity of Water given Value of Velocity of Sound in Water
Go Bulk Modulus of Water = (1434*Water Hammer Pressure In Environmental Eng.)/Flow Velocity of Fluid
Initial Velocity of Water given Value of Velocity of Sound in Water
Go Flow Velocity of Fluid = (Water Hammer Pressure In Environmental Eng.*1434)/Bulk Modulus of Water
Water Hammer Pressure given Value of Velocity of Sound in Water
Go Water Hammer Pressure In Environmental Eng. = (Flow Velocity of Fluid*Bulk Modulus of Water)/1434
Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water
Go Water Hammer Pressure In Environmental Eng. = (Ratio of Velocities*Bulk Modulus of Water)
Ratio of Velocity of Water to Velocity of Sound in Water given Water Hammer Pressure
Go Ratio of Velocities = Water Hammer Pressure In Environmental Eng./Bulk Modulus of Water
Bulk Modulus of Elasticity of Water given Ratio of Velocities
Go Bulk Modulus of Water = Water Hammer Pressure In Environmental Eng./Ratio of Velocities

Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water Formula

Water Hammer Pressure In Environmental Eng. = (Ratio of Velocities*Bulk Modulus of Water)
Pw = (VR*Kw)

What is Water Hammer Principle?

Water hammer is a pressure surge or wave caused when a fluid (usually a liquid but sometimes also a gas) in motion is forced to stop or change direction suddenly (momentum change). As soon as steam leaves the boiler, it starts losing heat.

How to Calculate Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water?

Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water calculator uses Water Hammer Pressure In Environmental Eng. = (Ratio of Velocities*Bulk Modulus of Water) to calculate the Water Hammer Pressure In Environmental Eng., The Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water is defined as the value of water hammer pressure when we have prior information of other parameters used. Water Hammer Pressure In Environmental Eng. is denoted by Pw symbol.

How to calculate Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water using this online calculator? To use this online calculator for Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water, enter Ratio of Velocities (VR) & Bulk Modulus of Water (Kw) and hit the calculate button. Here is how the Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water calculation can be explained with given input values -> 1.8E-6 = (0.9*2000000).

FAQ

What is Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water?
The Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water is defined as the value of water hammer pressure when we have prior information of other parameters used and is represented as Pw = (VR*Kw) or Water Hammer Pressure In Environmental Eng. = (Ratio of Velocities*Bulk Modulus of Water). Ratio of Velocities is the ratio of velocity of water to velocity of sound in water & Bulk Modulus of Water is defined as the proportion of volumetric stress linked to the volumetric strain of definite material, although the deformation of the material is within the elastic limit.
How to calculate Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water?
The Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water is defined as the value of water hammer pressure when we have prior information of other parameters used is calculated using Water Hammer Pressure In Environmental Eng. = (Ratio of Velocities*Bulk Modulus of Water). To calculate Water Hammer Pressure given Ratio of Velocity of Water to Velocity of Sound in Water, you need Ratio of Velocities (VR) & Bulk Modulus of Water (Kw). With our tool, you need to enter the respective value for Ratio of Velocities & Bulk Modulus of Water and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Water Hammer Pressure In Environmental Eng.?
In this formula, Water Hammer Pressure In Environmental Eng. uses Ratio of Velocities & Bulk Modulus of Water. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Water Hammer Pressure In Environmental Eng. = (Flow Velocity of Fluid*Bulk Modulus of Water)/Velocity of Sound in Water
  • Water Hammer Pressure In Environmental Eng. = (Flow Velocity of Fluid*Bulk Modulus of Water)/1434