Width of Tank given Settling Velocity of Particular Sized Particle Solution

STEP 0: Pre-Calculation Summary
Formula Used
Width = (70*Discharge)/(100*Length*Settling Velocity)
w = (70*Q)/(100*L*vs)
This formula uses 4 Variables
Variables Used
Width - (Measured in Meter) - Width is the measurement or extent of something from side to side.
Discharge - (Measured in Cubic Meter per Second) - Discharge is the rate of flow of a liquid.
Length - (Measured in Meter) - Length is the measurement or extent of something from end to end.
Settling Velocity - (Measured in Meter per Second) - Settling velocity is defined as the terminal velocity of a particle in still fluid.
STEP 1: Convert Input(s) to Base Unit
Discharge: 1.01 Cubic Meter per Second --> 1.01 Cubic Meter per Second No Conversion Required
Length: 3 Meter --> 3 Meter No Conversion Required
Settling Velocity: 1.5 Meter per Second --> 1.5 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
w = (70*Q)/(100*L*vs) --> (70*1.01)/(100*3*1.5)
Evaluating ... ...
w = 0.157111111111111
STEP 3: Convert Result to Output's Unit
0.157111111111111 Meter --> No Conversion Required
FINAL ANSWER
0.157111111111111 0.157111 Meter <-- Width
(Calculation completed in 00.004 seconds)

Credits

Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2200+ more calculators!
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

6 Width of Tank Calculators

Width of Tank given Height to Length Ratio
Go Width = (Discharge/(Settling Velocity*Depth))*(Ratio of height to length)
Width of Tank given Detention Time
Go Width = Detention time/((Length*Depth)/Discharge)
Width of Tank given Settling Velocity of Particular Sized Particle
Go Width = (70*Discharge)/(100*Length*Settling Velocity)
Width of Tank given Settling Velocity
Go Width = (Discharge/(Settling Velocity*Length))
Width of Tank given Overflow Rate
Go Width = (Discharge/(Overflow Rate*Length))
Width of Tank given Flow Velocity
Go Width = (Discharge/(Flow Velocity*Depth))

Width of Tank given Settling Velocity of Particular Sized Particle Formula

Width = (70*Discharge)/(100*Length*Settling Velocity)
w = (70*Q)/(100*L*vs)

What is discharge ?

The amount of fluid passing a section of a stream in unit time is called the discharge. If v is the mean velocity and A is the cross sectional area, the discharge Q is defined by Q = Av which is known as volume flow rate.

How to Calculate Width of Tank given Settling Velocity of Particular Sized Particle?

Width of Tank given Settling Velocity of Particular Sized Particle calculator uses Width = (70*Discharge)/(100*Length*Settling Velocity) to calculate the Width, Width of Tank given Settling Velocity of Particular Sized Particle calculates width of sedimentation tank when we have prior information of other parameters used. Width is denoted by w symbol.

How to calculate Width of Tank given Settling Velocity of Particular Sized Particle using this online calculator? To use this online calculator for Width of Tank given Settling Velocity of Particular Sized Particle, enter Discharge (Q), Length (L) & Settling Velocity (vs) and hit the calculate button. Here is how the Width of Tank given Settling Velocity of Particular Sized Particle calculation can be explained with given input values -> 0.155556 = (70*discharge)/(100*3*1.5).

FAQ

What is Width of Tank given Settling Velocity of Particular Sized Particle?
Width of Tank given Settling Velocity of Particular Sized Particle calculates width of sedimentation tank when we have prior information of other parameters used and is represented as w = (70*Q)/(100*L*vs) or Width = (70*Discharge)/(100*Length*Settling Velocity). Discharge is the rate of flow of a liquid, Length is the measurement or extent of something from end to end & Settling velocity is defined as the terminal velocity of a particle in still fluid.
How to calculate Width of Tank given Settling Velocity of Particular Sized Particle?
Width of Tank given Settling Velocity of Particular Sized Particle calculates width of sedimentation tank when we have prior information of other parameters used is calculated using Width = (70*Discharge)/(100*Length*Settling Velocity). To calculate Width of Tank given Settling Velocity of Particular Sized Particle, you need Discharge (Q), Length (L) & Settling Velocity (vs). With our tool, you need to enter the respective value for Discharge, Length & Settling Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Width?
In this formula, Width uses Discharge, Length & Settling Velocity. We can use 5 other way(s) to calculate the same, which is/are as follows -
  • Width = (Discharge/(Flow Velocity*Depth))
  • Width = (Discharge/(Settling Velocity*Length))
  • Width = (Discharge/(Settling Velocity*Depth))*(Ratio of height to length)
  • Width = (Discharge/(Overflow Rate*Length))
  • Width = Detention time/((Length*Depth)/Discharge)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!