Angular Frequency in Wien's Bridge Solution

STEP 0: Pre-Calculation Summary
Formula Used
Angular Frequency in Wein Bridge = 1/sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge)
ω(wein) = 1/sqrt(R1(wein)*R2(wein)*C1(wein)*C2(wein))
This formula uses 1 Functions, 5 Variables
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Angular Frequency in Wein Bridge - (Measured in Radian per Second) - Angular Frequency in Wein Bridge refers to the angular rate at which the AC signal oscillates.
Known Resistance 1 in Wein Bridge - (Measured in Ohm) - Known Resistance 1 in Wein Bridge refers to the total resistance in Wein bridge which is variable and can be used to determine the frequency.
Known Resistance 2 in Wein Bridge - (Measured in Ohm) - Known Resistance 2 in Wein Bridge refers to the total resistance in Wein bridge which is variable and can be used to determine the frequency.
Known Capacitance 1 in Wein Bridge - (Measured in Farad) - Known Capacitance 1 in Wein Bridge refers to the total capacitance in Wein bridge which is variable and can be used to determine the frequency.
Known Capacitance 2 in Wein Bridge - (Measured in Farad) - Known Capacitance 2 in Wein Bridge refers to the total capacitance in Wein bridge which is variable and can be used to determine the frequency.
STEP 1: Convert Input(s) to Base Unit
Known Resistance 1 in Wein Bridge: 27 Ohm --> 27 Ohm No Conversion Required
Known Resistance 2 in Wein Bridge: 26 Ohm --> 26 Ohm No Conversion Required
Known Capacitance 1 in Wein Bridge: 270 Microfarad --> 0.00027 Farad (Check conversion here)
Known Capacitance 2 in Wein Bridge: 275 Microfarad --> 0.000275 Farad (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
ω(wein) = 1/sqrt(R1(wein)*R2(wein)*C1(wein)*C2(wein)) --> 1/sqrt(27*26*0.00027*0.000275)
Evaluating ... ...
ω(wein) = 138.510665186438
STEP 3: Convert Result to Output's Unit
138.510665186438 Radian per Second --> No Conversion Required
FINAL ANSWER
138.510665186438 138.5107 Radian per Second <-- Angular Frequency in Wein Bridge
(Calculation completed in 00.004 seconds)

Credits

Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verified by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has verified this Calculator and 25+ more calculators!

3 Wien Bridge Calculators

Unknown Frequency in Wien Bridge
Go Unknown Frequency in Wein Bridge = 1/(2*pi*(sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge)))
Angular Frequency in Wien's Bridge
Go Angular Frequency in Wein Bridge = 1/sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge)
Resistance Ratio in Wien Bridge
Go Resistance Ratio in Wein Bridge = (Known Resistance 2 in Wein Bridge/Known Resistance 1 in Wein Bridge)+(Known Capacitance 1 in Wein Bridge/Known Capacitance 2 in Wein Bridge)

Angular Frequency in Wien's Bridge Formula

Angular Frequency in Wein Bridge = 1/sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge)
ω(wein) = 1/sqrt(R1(wein)*R2(wein)*C1(wein)*C2(wein))

What are the applications of Wien's bridge?

Wien's bridge is a versatile optical tool with numerous applications in spectroscopy, interferometry, and sensing. It can be used to measure the central wavelength of a spectral line, determine the optical path length of an irregular path, and provide a narrowband filter for spectral isolation. Additionally, it can act as an interferometer for testing optical components or a wavelength meter for monitoring the stretching of optical fibers.

How to Calculate Angular Frequency in Wien's Bridge?

Angular Frequency in Wien's Bridge calculator uses Angular Frequency in Wein Bridge = 1/sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge) to calculate the Angular Frequency in Wein Bridge, Angular Frequency in Wien's Bridge formula is used to calculate angular frequency of the AC signal applied to Wein Bridge. The angular frequency is an essential parameter in Wein Bridge circuits as it affects the stability, accuracy, and performance of the circuit. Proper selection of the angular frequency ensures reliable frequency measurements and accurate operation of the Wein Bridge circuit. Angular Frequency in Wein Bridge is denoted by ω(wein) symbol.

How to calculate Angular Frequency in Wien's Bridge using this online calculator? To use this online calculator for Angular Frequency in Wien's Bridge, enter Known Resistance 1 in Wein Bridge (R1(wein)), Known Resistance 2 in Wein Bridge (R2(wein)), Known Capacitance 1 in Wein Bridge (C1(wein)) & Known Capacitance 2 in Wein Bridge (C2(wein)) and hit the calculate button. Here is how the Angular Frequency in Wien's Bridge calculation can be explained with given input values -> 138.5107 = 1/sqrt(27*26*0.00027*0.000275).

FAQ

What is Angular Frequency in Wien's Bridge?
Angular Frequency in Wien's Bridge formula is used to calculate angular frequency of the AC signal applied to Wein Bridge. The angular frequency is an essential parameter in Wein Bridge circuits as it affects the stability, accuracy, and performance of the circuit. Proper selection of the angular frequency ensures reliable frequency measurements and accurate operation of the Wein Bridge circuit and is represented as ω(wein) = 1/sqrt(R1(wein)*R2(wein)*C1(wein)*C2(wein)) or Angular Frequency in Wein Bridge = 1/sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge). Known Resistance 1 in Wein Bridge refers to the total resistance in Wein bridge which is variable and can be used to determine the frequency, Known Resistance 2 in Wein Bridge refers to the total resistance in Wein bridge which is variable and can be used to determine the frequency, Known Capacitance 1 in Wein Bridge refers to the total capacitance in Wein bridge which is variable and can be used to determine the frequency & Known Capacitance 2 in Wein Bridge refers to the total capacitance in Wein bridge which is variable and can be used to determine the frequency.
How to calculate Angular Frequency in Wien's Bridge?
Angular Frequency in Wien's Bridge formula is used to calculate angular frequency of the AC signal applied to Wein Bridge. The angular frequency is an essential parameter in Wein Bridge circuits as it affects the stability, accuracy, and performance of the circuit. Proper selection of the angular frequency ensures reliable frequency measurements and accurate operation of the Wein Bridge circuit is calculated using Angular Frequency in Wein Bridge = 1/sqrt(Known Resistance 1 in Wein Bridge*Known Resistance 2 in Wein Bridge*Known Capacitance 1 in Wein Bridge*Known Capacitance 2 in Wein Bridge). To calculate Angular Frequency in Wien's Bridge, you need Known Resistance 1 in Wein Bridge (R1(wein)), Known Resistance 2 in Wein Bridge (R2(wein)), Known Capacitance 1 in Wein Bridge (C1(wein)) & Known Capacitance 2 in Wein Bridge (C2(wein)). With our tool, you need to enter the respective value for Known Resistance 1 in Wein Bridge, Known Resistance 2 in Wein Bridge, Known Capacitance 1 in Wein Bridge & Known Capacitance 2 in Wein Bridge and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!