Pole Frequency of STC Networks for Low-Pass Solution

STEP 0: Pre-Calculation Summary
Formula Used
Pole Frequency Low Pass = 1/Time Constant
fLp = 1/τ
This formula uses 2 Variables
Variables Used
Pole Frequency Low Pass - (Measured in Hertz) - Pole Frequency Low Pass denotes the frequency at which the filter's response decreases by 3 dB, indicating the cutoff point beyond which higher frequencies are significantly attenuated.
Time Constant - (Measured in Second) - Time Constant of the response represents the elapsed time required for the system response to decay to zero if the system had continued to decay at the initial rate in amplifiers.
STEP 1: Convert Input(s) to Base Unit
Time Constant: 2.05 Millisecond --> 0.00205 Second (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
fLp = 1/τ --> 1/0.00205
Evaluating ... ...
fLp = 487.80487804878
STEP 3: Convert Result to Output's Unit
487.80487804878 Hertz --> No Conversion Required
FINAL ANSWER
487.80487804878 487.8049 Hertz <-- Pole Frequency Low Pass
(Calculation completed in 00.004 seconds)

Credits

Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

5 STC Network Calculators

Pole Frequency of STC Circuit for High-Pass
Go Pole Frequency High Pass = 1/((Emitter-Base Capacitance+Collector-Base Junction Capacitance)*Finite Input Resistance)
Input Capacitance of STC Circuit
Go Input Capacitance of STC = Total Capacitance+Gate to Source Capacitance
Input Capacitance with reference to Corner Frequency
Go Input Capacitance = 1/(Pole Frequency of STC Filter*Signal Resistance)
Pole Frequency of STC Circuit
Go Pole Frequency of STC Filter = 1/(Input Capacitance*Signal Resistance)
Pole Frequency of STC Networks for Low-Pass
Go Pole Frequency Low Pass = 1/Time Constant

Pole Frequency of STC Networks for Low-Pass Formula

Pole Frequency Low Pass = 1/Time Constant
fLp = 1/τ

What is 3-dB Frequency?

The 3-dB Frequency of STC Networks for low-pass frequency formula is the pole frequency or corner frequency or break frequency. It is the frequency at which the power is at 3db below the maximum value. It is calculated the same way for high pass and low pass filters.

Calculation of 3-dB Frequency

fₒ=wₒ/2π [wₒ=(Rₛ+Rᵢ)/(Cᵢ*Rₛ* Rᵢ )]
where Rₛ is source resistance, Rᵢ is the input resistance of amplifier and Cᵢ is input capacitance of the amplifier

How to Calculate Pole Frequency of STC Networks for Low-Pass?

Pole Frequency of STC Networks for Low-Pass calculator uses Pole Frequency Low Pass = 1/Time Constant to calculate the Pole Frequency Low Pass, Pole Frequency of STC Networks for Low-Pass marks the cutoff where the output signal decreases by 3 dB,representing the boundary between allowed and attenuated frequencies. Pole Frequency Low Pass is denoted by fLp symbol.

How to calculate Pole Frequency of STC Networks for Low-Pass using this online calculator? To use this online calculator for Pole Frequency of STC Networks for Low-Pass, enter Time Constant (τ) and hit the calculate button. Here is how the Pole Frequency of STC Networks for Low-Pass calculation can be explained with given input values -> 487.8049 = 1/0.00205.

FAQ

What is Pole Frequency of STC Networks for Low-Pass?
Pole Frequency of STC Networks for Low-Pass marks the cutoff where the output signal decreases by 3 dB,representing the boundary between allowed and attenuated frequencies and is represented as fLp = 1/τ or Pole Frequency Low Pass = 1/Time Constant. Time Constant of the response represents the elapsed time required for the system response to decay to zero if the system had continued to decay at the initial rate in amplifiers.
How to calculate Pole Frequency of STC Networks for Low-Pass?
Pole Frequency of STC Networks for Low-Pass marks the cutoff where the output signal decreases by 3 dB,representing the boundary between allowed and attenuated frequencies is calculated using Pole Frequency Low Pass = 1/Time Constant. To calculate Pole Frequency of STC Networks for Low-Pass, you need Time Constant (τ). With our tool, you need to enter the respective value for Time Constant and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!