AC Voltage Solution

STEP 0: Pre-Calculation Summary
Formula Used
Meter Voltage Rectifier = Peak Value of Voltage*sin(Angular Frequency Rectifier*Time)
V' = Vm*sin(ωr*t)
This formula uses 1 Functions, 4 Variables
Functions Used
sin - Sine is a trigonometric function that describes the ratio of the length of the opposite side of a right triangle to the length of the hypotenuse., sin(Angle)
Variables Used
Meter Voltage Rectifier - (Measured in Volt) - Meter Voltage Rectifier is the amount of potential difference across two ends of the meter.
Peak Value of Voltage - (Measured in Volt) - Peak value of Voltage is the maximum value of AC voltage.
Angular Frequency Rectifier - (Measured in Radian per Second) - Angular frequency Rectifier represents the rate of change of angle per unit time in oscillatory motion.
Time - (Measured in Second) - Time is the time taken for one wave cycle.
STEP 1: Convert Input(s) to Base Unit
Peak Value of Voltage: 7 Volt --> 7 Volt No Conversion Required
Angular Frequency Rectifier: 10.05 Radian per Second --> 10.05 Radian per Second No Conversion Required
Time: 12 Second --> 12 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V' = Vm*sin(ωr*t) --> 7*sin(10.05*12)
Evaluating ... ...
V' = 6.57244172014219
STEP 3: Convert Result to Output's Unit
6.57244172014219 Volt --> No Conversion Required
FINAL ANSWER
6.57244172014219 6.572442 Volt <-- Meter Voltage Rectifier
(Calculation completed in 00.004 seconds)

Credits

Created by Nikita Suryawanshi
Vellore Institute of Technology (VIT), Vellore
Nikita Suryawanshi has created this Calculator and 100+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

11 Rectifier Type Voltmeter Calculators

Rs for DC Operation Full Wave
Go Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-(2*Resistance of Diode)
Rs for AC Operation Full Wave
Go Shunt Meter Resistance Full Wave = (Voltage RMS Value*Sensitivity of AC Meter)-Resistance of Multiplier-(2*Resistance of Diode)
Rs for DC Operation Half Wave
Go Shunt Meter Resistance Half Wave = (Voltage RMS Value*Sensitivity of DC Meter)-Resistance of Multiplier-Resistance of Diode
Rs for AC Operation Half Wave
Go Shunt Meter Resistance Half Wave = (Voltage RMS Value*Sensitivity of AC Meter)-Resistance of Multiplier-Resistance of Diode
AC Voltage
Go Meter Voltage Rectifier = Peak Value of Voltage*sin(Angular Frequency Rectifier*Time)
Vrms value
Go Voltage RMS Value = Peak Value of Voltage/sqrt(2)
Vav of Half Wave Rectifier
Go Average Voltmeter Half Rectifier = 0.45*Voltage RMS Value
DC Meter Sensitivity
Go Sensitivity of DC Meter = 1/Full Scale Current Deflection
AC Meter Sensitivity for Half Wave Rectifier
Go Sensitivity of AC Meter = 0.45*Sensitivity of DC Meter
Vav of Full Scale Rectifier
Go Average Voltage Full Rectifier = 0.9*Voltage RMS Value
AC Meter Sensitivity for Full Wave Rectifier
Go Sensitivity of AC Meter = 0.9*Sensitivity of DC Meter

AC Voltage Formula

Meter Voltage Rectifier = Peak Value of Voltage*sin(Angular Frequency Rectifier*Time)
V' = Vm*sin(ωr*t)

How does Rectifier type instrument work?

Rectifier type instrument converts AC input to uni directional DC output and then uses a meter responsive to DC to indicate the value of rectified AC. It is primarily a voltmeter. Measurement is carried out on a communication circuit, where voltage is low and resistance is high.

How to Calculate AC Voltage?

AC Voltage calculator uses Meter Voltage Rectifier = Peak Value of Voltage*sin(Angular Frequency Rectifier*Time) to calculate the Meter Voltage Rectifier, The AC Voltage is the value of voltage applied to the rectifier circuit of the instrument, whose amplitude is Vm. Meter Voltage Rectifier is denoted by V' symbol.

How to calculate AC Voltage using this online calculator? To use this online calculator for AC Voltage, enter Peak Value of Voltage (Vm), Angular Frequency Rectifier r) & Time (t) and hit the calculate button. Here is how the AC Voltage calculation can be explained with given input values -> 4.064278 = 7*sin(10.05*12).

FAQ

What is AC Voltage?
The AC Voltage is the value of voltage applied to the rectifier circuit of the instrument, whose amplitude is Vm and is represented as V' = Vm*sin(ωr*t) or Meter Voltage Rectifier = Peak Value of Voltage*sin(Angular Frequency Rectifier*Time). Peak value of Voltage is the maximum value of AC voltage, Angular frequency Rectifier represents the rate of change of angle per unit time in oscillatory motion & Time is the time taken for one wave cycle.
How to calculate AC Voltage?
The AC Voltage is the value of voltage applied to the rectifier circuit of the instrument, whose amplitude is Vm is calculated using Meter Voltage Rectifier = Peak Value of Voltage*sin(Angular Frequency Rectifier*Time). To calculate AC Voltage, you need Peak Value of Voltage (Vm), Angular Frequency Rectifier r) & Time (t). With our tool, you need to enter the respective value for Peak Value of Voltage, Angular Frequency Rectifier & Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!