Attenuation given Voltage of 2 Signals Solution

STEP 0: Pre-Calculation Summary
Formula Used
Attenuation = 20*(log10(Voltage 2/Voltage 1))
dB = 20*(log10(V2/V1))
This formula uses 1 Functions, 3 Variables
Functions Used
log10 - The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function., log10(Number)
Variables Used
Attenuation - (Measured in Decibel) - Attenuation is defined as the loss of information from a signal.
Voltage 2 - (Measured in Volt) - Voltage 2 in Digital Communication the pressure from an electrical circuit's power source that pushes charged electrons (current) through a conducting loop.
Voltage 1 - (Measured in Volt) - Voltage 1 in Digital Communication is the pressure from an electrical circuit's power source that pushes charged electrons through a conducting loop.
STEP 1: Convert Input(s) to Base Unit
Voltage 2: 20 Volt --> 20 Volt No Conversion Required
Voltage 1: 70 Volt --> 70 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
dB = 20*(log10(V2/V1)) --> 20*(log10(20/70))
Evaluating ... ...
dB = -10.8813608870055
STEP 3: Convert Result to Output's Unit
-10.8813608870055 Decibel --> No Conversion Required
FINAL ANSWER
-10.8813608870055 -10.881361 Decibel <-- Attenuation
(Calculation completed in 00.004 seconds)

Credits

Created by Akshada Kulkarni
National Institute of Information Technology (NIIT), Neemrana
Akshada Kulkarni has created this Calculator and 500+ more calculators!
Verified by Suman Ray Pramanik
Indian Institute of Technology (IIT), Kanpur
Suman Ray Pramanik has verified this Calculator and 100+ more calculators!

11 Modulation Parameters Calculators

Quantization Step Size
Go Quantization Step Size = (Maximum Voltage-Minimum Voltage)/Number of Quantisation Levels
Bit Rate of Raised Cosine Filter using Rolloff Factor
Go Bit Rate of Raised Cosine Filter = (2*Bandwidth of Raised Cosine Filter)/(1+Rolloff Factor)
Attenuation given Voltage of 2 Signals
Go Attenuation = 20*(log10(Voltage 2/Voltage 1))
Attenuation given Power of 2 Signals
Go Attenuation = 10*(log10(Power 2/Power 1))
Number of Samples
Go Number of Samples = Maximum Frequency/Sampling Frequency
Bit Rate
Go Bit Rate = Sampling Frequency*Bit Depth
Bit Rate of Raised Cosine Filter given Time Period
Go Bit Rate of Raised Cosine Filter = 1/Signal Time Period
Signal to Noise Ratio
Go Signal to Noise Ratio = (6.02*Resolution of ADC)+1.76
Number of Quantization Levels
Go Number of Quantisation Levels = 2^Resolution of ADC
Nyquist Sampling Frequency
Go Sampling Frequency = 2*Message Signal Frequency
Bit Rate using Bit Duration
Go Bit Rate = 1/Bit Duration

Attenuation given Voltage of 2 Signals Formula

Attenuation = 20*(log10(Voltage 2/Voltage 1))
dB = 20*(log10(V2/V1))

What is meant by attenuation?

Attenuation is used to measure the loss or gain of signal through the voltage of the two signals. It is measured in terms of decibels(dB). To compensate the loss of energy and the reduction of amplitude, we can use amplifier to increase the amplitude of the message signal.

How to Calculate Attenuation given Voltage of 2 Signals?

Attenuation given Voltage of 2 Signals calculator uses Attenuation = 20*(log10(Voltage 2/Voltage 1)) to calculate the Attenuation, Attenuation given Voltage of 2 Signals is the loss of energy due to conduction loss or multipath fading. Attenuation is denoted by dB symbol.

How to calculate Attenuation given Voltage of 2 Signals using this online calculator? To use this online calculator for Attenuation given Voltage of 2 Signals, enter Voltage 2 (V2) & Voltage 1 (V1) and hit the calculate button. Here is how the Attenuation given Voltage of 2 Signals calculation can be explained with given input values -> -10.881361 = 20*(log10(20/70)).

FAQ

What is Attenuation given Voltage of 2 Signals?
Attenuation given Voltage of 2 Signals is the loss of energy due to conduction loss or multipath fading and is represented as dB = 20*(log10(V2/V1)) or Attenuation = 20*(log10(Voltage 2/Voltage 1)). Voltage 2 in Digital Communication the pressure from an electrical circuit's power source that pushes charged electrons (current) through a conducting loop & Voltage 1 in Digital Communication is the pressure from an electrical circuit's power source that pushes charged electrons through a conducting loop.
How to calculate Attenuation given Voltage of 2 Signals?
Attenuation given Voltage of 2 Signals is the loss of energy due to conduction loss or multipath fading is calculated using Attenuation = 20*(log10(Voltage 2/Voltage 1)). To calculate Attenuation given Voltage of 2 Signals, you need Voltage 2 (V2) & Voltage 1 (V1). With our tool, you need to enter the respective value for Voltage 2 & Voltage 1 and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Attenuation?
In this formula, Attenuation uses Voltage 2 & Voltage 1. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Attenuation = 10*(log10(Power 2/Power 1))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!