Average Load Current of Three Phase Uncontrolled Rectifier Solution

STEP 0: Pre-Calculation Summary
Formula Used
Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance)
IL(avg) = (3*sqrt(3)*n*Vmax)/(2*pi*RL)
This formula uses 1 Constants, 1 Functions, 4 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Average Load Current - (Measured in Ampere) - Average load current is a measure of the average current flowing through a load in an electrical circuit over a given period of time.
Winding Ratio - Winding Ratio of an uncontrolled rectifier is the ratio of the number of turns on the primary winding to the number of turns on the secondary winding of the transformer.
Peak Input Voltage - (Measured in Volt) - Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit.
Load Resistance - (Measured in Ohm) - Load Resistance of uncontrolled rectifier is a type of rectifier circuit that uses a resistive load to convert AC voltage to DC voltage.
STEP 1: Convert Input(s) to Base Unit
Winding Ratio: 15 --> No Conversion Required
Peak Input Voltage: 220 Volt --> 220 Volt No Conversion Required
Load Resistance: 6.99 Ohm --> 6.99 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
IL(avg) = (3*sqrt(3)*n*Vmax)/(2*pi*RL) --> (3*sqrt(3)*15*220)/(2*pi*6.99)
Evaluating ... ...
IL(avg) = 390.426041822299
STEP 3: Convert Result to Output's Unit
390.426041822299 Ampere --> No Conversion Required
FINAL ANSWER
390.426041822299 390.426 Ampere <-- Average Load Current
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mohamed Fazil V
Acharya institute of technology (AIT), Bengaluru
Mohamed Fazil V has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 600+ more calculators!

9 Full Wave Calculators

RMS Load Current of Three Phase Uncontrolled Rectifier
​ Go RMS Load Current = (Winding Ratio*Peak Input Voltage)/(Load Resistance*sqrt(2))*sqrt(1+(3*sqrt(3))/(2*pi))
RMS Diode Current of Three Phase Uncontrolled Rectifier
​ Go RMS Diode Current = (Winding Ratio*Peak Input Voltage)/(Load Resistance*sqrt(2))*sqrt(1/3+sqrt(3)/(4*pi))
RMS Load Voltage of Three Phase Uncontrolled Rectifier
​ Go RMS Load Voltage = (Winding Ratio*Peak Input Voltage)/sqrt(2)*sqrt(1+(3*sqrt(3))/(2*pi))
Average Load Current of Three Phase Uncontrolled Rectifier
​ Go Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance)
Average Diode Current of Three Phase Uncontrolled Rectifier
​ Go Average Diode Current = (sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance)
Load Current of DC Three Phase Uncontrolled Rectifier
​ Go DC Load Current = (3*sqrt(3)*Peak Input Voltage)/(2*pi*Load Resistance)
Load Voltage of DC Three Phase Uncontrolled Rectifier
​ Go DC Load Voltage = (3*sqrt(3)*Peak Input Voltage)/(2*pi)
Load Voltage of Full Wave Three Phase Uncontrolled Rectifier
​ Go AC Voltage = (2*Winding Ratio*Peak Input Voltage)/pi
Power Delivered to Load in Three Phase Uncontrolled Rectifier
​ Go Delivery Power = AC Voltage*Average Output Voltage

Average Load Current of Three Phase Uncontrolled Rectifier Formula

Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance)
IL(avg) = (3*sqrt(3)*n*Vmax)/(2*pi*RL)

What is Average Load Current of Three Phase Uncontrolled Rectifier?

The average load current of an uncontrolled rectifier depends on the configuration of the rectifier, the input voltage, and the load. Uncontrolled rectifiers are typically used for converting alternating current (AC) to direct current (DC) without any control over the output voltage. The average load current can be calculated based on the rectifier type and load.

How to Calculate Average Load Current of Three Phase Uncontrolled Rectifier?

Average Load Current of Three Phase Uncontrolled Rectifier calculator uses Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance) to calculate the Average Load Current, Average Load Current of Three Phase Uncontrolled Rectifier is the DC current that flows through the load resistor. The average load current of an uncontrolled rectifier is an important parameter that must be considered when designing a rectifier circuit. It is important to choose diodes with a current rating that is greater than the RMS load current in order to prevent the diodes from overheating. Average Load Current is denoted by IL(avg) symbol.

How to calculate Average Load Current of Three Phase Uncontrolled Rectifier using this online calculator? To use this online calculator for Average Load Current of Three Phase Uncontrolled Rectifier, enter Winding Ratio (n), Peak Input Voltage (Vmax) & Load Resistance (RL) and hit the calculate button. Here is how the Average Load Current of Three Phase Uncontrolled Rectifier calculation can be explained with given input values -> 390.426 = (3*sqrt(3)*15*220)/(2*pi*6.99).

FAQ

What is Average Load Current of Three Phase Uncontrolled Rectifier?
Average Load Current of Three Phase Uncontrolled Rectifier is the DC current that flows through the load resistor. The average load current of an uncontrolled rectifier is an important parameter that must be considered when designing a rectifier circuit. It is important to choose diodes with a current rating that is greater than the RMS load current in order to prevent the diodes from overheating and is represented as IL(avg) = (3*sqrt(3)*n*Vmax)/(2*pi*RL) or Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance). Winding Ratio of an uncontrolled rectifier is the ratio of the number of turns on the primary winding to the number of turns on the secondary winding of the transformer, Peak Input Voltage is the peak of the alternating voltage provided at the input of any electrical circuit & Load Resistance of uncontrolled rectifier is a type of rectifier circuit that uses a resistive load to convert AC voltage to DC voltage.
How to calculate Average Load Current of Three Phase Uncontrolled Rectifier?
Average Load Current of Three Phase Uncontrolled Rectifier is the DC current that flows through the load resistor. The average load current of an uncontrolled rectifier is an important parameter that must be considered when designing a rectifier circuit. It is important to choose diodes with a current rating that is greater than the RMS load current in order to prevent the diodes from overheating is calculated using Average Load Current = (3*sqrt(3)*Winding Ratio*Peak Input Voltage)/(2*pi*Load Resistance). To calculate Average Load Current of Three Phase Uncontrolled Rectifier, you need Winding Ratio (n), Peak Input Voltage (Vmax) & Load Resistance (RL). With our tool, you need to enter the respective value for Winding Ratio, Peak Input Voltage & Load Resistance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.