Back Pitch for DC Machine Solution

STEP 0: Pre-Calculation Summary
Formula Used
Back Pitch = ((2*Number of Slots)/Number of Poles)+1
Yb = ((2*nslot)/P)+1
This formula uses 3 Variables
Variables Used
Back Pitch - Back Pitch refers to the distance between two consecutive sides of a coil measured along the surface of the armature.
Number of Slots - Number of Slotsdepends on various factors such as the size of the generator, the type of winding used, the desired output voltage, and the power rating.
Number of Poles - Number of Poles refers to the total count of poles in an electrical machine for the flux generation.
STEP 1: Convert Input(s) to Base Unit
Number of Slots: 96 --> No Conversion Required
Number of Poles: 9 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Yb = ((2*nslot)/P)+1 --> ((2*96)/9)+1
Evaluating ... ...
Yb = 22.3333333333333
STEP 3: Convert Result to Output's Unit
22.3333333333333 --> No Conversion Required
FINAL ANSWER
22.3333333333333 22.33333 <-- Back Pitch
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Team Softusvista
Softusvista Office (Pune), India
Team Softusvista has verified this Calculator and 1100+ more calculators!

DC Machine Characterstics Calculators

Design Constant of DC Machine
​ Go Machine Constant = (Number of Conductors*Number of Poles)/(2*pi*Number of Parallel Paths)
Angular Speed of DC Machine using Kf
​ Go Angular Speed = Armature Voltage/(Machine Constant*Magnetic Flux*Armature Current)
Front Pitch for DC Machine
​ Go Front Pitch = ((2*Number of Slots)/Number of Poles)-1
Back Pitch for DC Machine
​ Go Back Pitch = ((2*Number of Slots)/Number of Poles)+1

Back Pitch for DC Machine Formula

Back Pitch = ((2*Number of Slots)/Number of Poles)+1
Yb = ((2*nslot)/P)+1

How many input and output powers does synchronous generator have?

The synchronous generator has two power inputs, mechanical power at the shaft and electrical power to the field, and one output, electrical power to a load.

How to Calculate Back Pitch for DC Machine?

Back Pitch for DC Machine calculator uses Back Pitch = ((2*Number of Slots)/Number of Poles)+1 to calculate the Back Pitch, The Back Pitch for DC Machine formula is defined as the coil advances on the back of the armature. This advancement is measured in terms of armature conductors and is called back pitch. It is equal to the number difference of the conductor connected to a given segment of the commutator. Back Pitch is denoted by Yb symbol.

How to calculate Back Pitch for DC Machine using this online calculator? To use this online calculator for Back Pitch for DC Machine, enter Number of Slots (nslot) & Number of Poles (P) and hit the calculate button. Here is how the Back Pitch for DC Machine calculation can be explained with given input values -> 22.33333 = ((2*96)/9)+1.

FAQ

What is Back Pitch for DC Machine?
The Back Pitch for DC Machine formula is defined as the coil advances on the back of the armature. This advancement is measured in terms of armature conductors and is called back pitch. It is equal to the number difference of the conductor connected to a given segment of the commutator and is represented as Yb = ((2*nslot)/P)+1 or Back Pitch = ((2*Number of Slots)/Number of Poles)+1. Number of Slotsdepends on various factors such as the size of the generator, the type of winding used, the desired output voltage, and the power rating & Number of Poles refers to the total count of poles in an electrical machine for the flux generation.
How to calculate Back Pitch for DC Machine?
The Back Pitch for DC Machine formula is defined as the coil advances on the back of the armature. This advancement is measured in terms of armature conductors and is called back pitch. It is equal to the number difference of the conductor connected to a given segment of the commutator is calculated using Back Pitch = ((2*Number of Slots)/Number of Poles)+1. To calculate Back Pitch for DC Machine, you need Number of Slots (nslot) & Number of Poles (P). With our tool, you need to enter the respective value for Number of Slots & Number of Poles and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Back Pitch?
In this formula, Back Pitch uses Number of Slots & Number of Poles. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Back Pitch = Coil Span*Coil Span Factor
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!