Clearance Area under Downcomer given Weir Length and Apron Height Solution

STEP 0: Pre-Calculation Summary
Formula Used
Clearance Area Under Downcomer = Apron Height*Weir Length
Aap = hap*lw
This formula uses 3 Variables
Variables Used
Clearance Area Under Downcomer - (Measured in Square Meter) - Clearance Area Under Downcomer refers to the open space or gap designed into the downcomer to allow the flow of liquid from one tray to the tray below.
Apron Height - (Measured in Meter) - Apron Height refers to the vertical distance between the liquid level on a tray and the bottom of the downcomer.
Weir Length - (Measured in Meter) - The weir length refers to the length of support strips which plays a significant role in controlling liquid distribution, within the column.
STEP 1: Convert Input(s) to Base Unit
Apron Height: 0.045 Meter --> 0.045 Meter No Conversion Required
Weir Length: 2.452 Meter --> 2.452 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Aap = hap*lw --> 0.045*2.452
Evaluating ... ...
Aap = 0.11034
STEP 3: Convert Result to Output's Unit
0.11034 Square Meter --> No Conversion Required
FINAL ANSWER
0.11034 Square Meter <-- Clearance Area Under Downcomer
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

25 Distillation Tower Design Calculators

Relative Volatility of Two Components Based on Normal Boiling Point and Latent Heat of Vaporization
​ Go Relative Volatility = exp(0.25164*((1/Normal Boiling Point of Component 1)-(1/Normal Boiling Point of Component 2))*(Latent Heat of Vaporization of Component 1+Latent Heat of Vaporization of Component 2))
Maximum Allowable Vapor Velocity given Plate Spacing and Fluid Densities
​ Go Maximum Allowable Vapor Velocity = (-0.171*(Plate Spacing)^2+0.27*Plate Spacing-0.047)*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
​ Go Column Diameter = sqrt((4*Vapor Mass Flowrate)/(pi*Vapor Density in Distillation*Maximum Allowable Vapor Velocity))
Tower Cross Sectional Area given Gas Volumetric Flow and Flooding Velocity
​ Go Tower Cross Sectional Area = Volumetric Gas Flow/((Fractional Approach to Flooding Velocity*Flooding Velocity)*(1-Fractional Downcomer Area))
Minimum External Reflux given Compositions
​ Go External Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Equilibrium Vapor Composition-Equilibrium Liquid Composition)
Maximum Allowable Mass Velocity using Bubble Cap Trays
​ Go Maximum Allowable Mass Velocity = Entrainment Factor*(Vapor Density in Distillation*(Liquid Density-Vapor Density in Distillation)^(1/2))
Minimum Internal Reflux given Compositions
​ Go Internal Reflux Ratio = (Distillate Composition-Equilibrium Vapor Composition)/(Distillate Composition-Equilibrium Liquid Composition)
Dry Plate Pressure Drop in Distillation Column Design
​ Go Dry Plate Head Loss = 51*((Vapor Velocity Based on Hole Area/Orifice Coefficient)^2)*(Vapor Density in Distillation/Liquid Density)
Flooding Velocity in Distillation Column Design
​ Go Flooding Velocity = Capacity Factor*((Liquid Density-Vapor Density in Distillation)/Vapor Density in Distillation)^0.5
Weep Point Velocity in Distillation Column Design
​ Go Weep Point Vapor Velocity Based on Hole Area = (Weep Point Correlation Constant-0.90*(25.4-Hole Diameter))/((Vapor Density in Distillation)^0.5)
Liquid Vapor Flow Factor in Distillation Column Design
​ Go Flow Factor = (Liquid Mass Flowrate/Vapor Mass Flowrate)*((Vapor Density in Distillation/Liquid Density)^0.5)
Downcomer Residence Time in Distillation Column
​ Go Residence Time = (Downcomer Area*Clear Liquid Backup*Liquid Density)/Liquid Mass Flowrate
Internal Reflux Ratio Based on Liquid and Distillate Flowrates
​ Go Internal Reflux Ratio = Liquid Reflux Flowrate/(Liquid Reflux Flowrate+Distillate Flowrate)
Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
​ Go Column Diameter = ((4*Vapor Mass Flowrate)/(pi*Maximum Allowable Mass Velocity))^(1/2)
Head Loss in Downcomer of Tray Tower
​ Go Downcomer Headloss = 166*((Liquid Mass Flowrate/(Liquid Density*Downcomer Area)))^2
Height of Liquid Crest over Weir
​ Go Weir Crest = (750/1000)*((Liquid Mass Flowrate/(Weir Length*Liquid Density))^(2/3))
Active Area given Gas Volumetric Flow and Flow Velocity
​ Go Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity)
Fractional Downcomer Area given Total Cross Sectional Area
​ Go Fractional Downcomer Area = 2*(Downcomer Area/Tower Cross Sectional Area)
Fractional Active Area given Downcomer Area and Total Column Area
​ Go Fractional Active Area = 1-2*(Downcomer Area/Tower Cross Sectional Area)
Internal Reflux Ratio Given External Reflux Ratio
​ Go Internal Reflux Ratio = External Reflux Ratio/(External Reflux Ratio+1)
Tower Cross Sectional Area given Fractional Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Tower Cross Sectional Area given Active Area
​ Go Tower Cross Sectional Area = Active Area/(1-Fractional Downcomer Area)
Clearance Area under Downcomer given Weir Length and Apron Height
​ Go Clearance Area Under Downcomer = Apron Height*Weir Length
Fractional Active Area given Fractional Downcomer Area
​ Go Fractional Active Area = 1-Fractional Downcomer Area
Residual Head Loss in Pressure in Distillation Column
​ Go Residual Head Loss = (12.5*10^3)/Liquid Density

Clearance Area under Downcomer given Weir Length and Apron Height Formula

Clearance Area Under Downcomer = Apron Height*Weir Length
Aap = hap*lw

What is the Role of Clearance Area under Downcomer?

The clearance area facilitates the downward flow of liquid from an upper tray to a lower tray. This flow is essential for the distillation process, as it allows liquid and vapor to come into contact on each tray, promoting the separation of components.
The clearance area, combined with other design features like the weir and tray geometry, helps distribute liquid evenly across the tray. This is crucial for achieving optimal separation in the column.

How to Calculate Clearance Area under Downcomer given Weir Length and Apron Height?

Clearance Area under Downcomer given Weir Length and Apron Height calculator uses Clearance Area Under Downcomer = Apron Height*Weir Length to calculate the Clearance Area Under Downcomer, The Clearance Area under Downcomer given Weir Length and Apron Height formula is defined as the open space or gap designed into the downcomer to allow the flow of liquid from one tray to the tray below. Clearance Area Under Downcomer is denoted by Aap symbol.

How to calculate Clearance Area under Downcomer given Weir Length and Apron Height using this online calculator? To use this online calculator for Clearance Area under Downcomer given Weir Length and Apron Height, enter Apron Height (hap) & Weir Length (lw) and hit the calculate button. Here is how the Clearance Area under Downcomer given Weir Length and Apron Height calculation can be explained with given input values -> 0.11034 = 0.045*2.452.

FAQ

What is Clearance Area under Downcomer given Weir Length and Apron Height?
The Clearance Area under Downcomer given Weir Length and Apron Height formula is defined as the open space or gap designed into the downcomer to allow the flow of liquid from one tray to the tray below and is represented as Aap = hap*lw or Clearance Area Under Downcomer = Apron Height*Weir Length. Apron Height refers to the vertical distance between the liquid level on a tray and the bottom of the downcomer & The weir length refers to the length of support strips which plays a significant role in controlling liquid distribution, within the column.
How to calculate Clearance Area under Downcomer given Weir Length and Apron Height?
The Clearance Area under Downcomer given Weir Length and Apron Height formula is defined as the open space or gap designed into the downcomer to allow the flow of liquid from one tray to the tray below is calculated using Clearance Area Under Downcomer = Apron Height*Weir Length. To calculate Clearance Area under Downcomer given Weir Length and Apron Height, you need Apron Height (hap) & Weir Length (lw). With our tool, you need to enter the respective value for Apron Height & Weir Length and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!