Design Power for V Belt Solution

STEP 0: Pre-Calculation Summary
Formula Used
Design Power of Belt Drive = Correction Factor for Industrial Service*Power transmitted by belt
Pd = Far*Pt
This formula uses 3 Variables
Variables Used
Design Power of Belt Drive - (Measured in Watt) - Design Power of Belt Drive is defined as the power transmitted on the basis of the design.
Correction Factor for Industrial Service - Correction Factor for Industrial Service is the correction factor that is used for industrial purpose.
Power transmitted by belt - (Measured in Watt) - Power transmitted by belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
STEP 1: Convert Input(s) to Base Unit
Correction Factor for Industrial Service: 1.3 --> No Conversion Required
Power transmitted by belt: 6.45 Kilowatt --> 6450 Watt (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pd = Far*Pt --> 1.3*6450
Evaluating ... ...
Pd = 8385
STEP 3: Convert Result to Output's Unit
8385 Watt -->8.385 Kilowatt (Check conversion ​here)
FINAL ANSWER
8.385 Kilowatt <-- Design Power of Belt Drive
(Calculation completed in 00.006 seconds)

Credits

Creator Image
Created by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has created this Calculator and 1000+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Selection of V Belts Calculators

Pitch diameter of big pulley of V Belt drive
​ LaTeX ​ Go Diameter of Big Pulley = Diameter of Small Pulley*(Speed of Smaller Pulley/Speed of Larger Pulley)
Correction Factor for Industrial Service given Design Power
​ LaTeX ​ Go Correction Factor for Industrial Service = Design Power of Belt Drive/Power transmitted by belt
Transmitted Power given Design Power
​ LaTeX ​ Go Power transmitted by belt = Design Power of Belt Drive/Correction Factor for Industrial Service
Design Power for V Belt
​ LaTeX ​ Go Design Power of Belt Drive = Correction Factor for Industrial Service*Power transmitted by belt

Design Power for V Belt Formula

​LaTeX ​Go
Design Power of Belt Drive = Correction Factor for Industrial Service*Power transmitted by belt
Pd = Far*Pt

Define a Belt Drive?

A belt drive is a transmission system that uses a flexible strip to transfer power. The turning disk is connected by a belt drive to the electric motor. A rubber belt drive is used to transfer power from one pulley to another.

How to Calculate Design Power for V Belt?

Design Power for V Belt calculator uses Design Power of Belt Drive = Correction Factor for Industrial Service*Power transmitted by belt to calculate the Design Power of Belt Drive, Design Power for V Belt formula is defined as the power produced or transmitted by a device on basis of its design of construction. Design Power of Belt Drive is denoted by Pd symbol.

How to calculate Design Power for V Belt using this online calculator? To use this online calculator for Design Power for V Belt, enter Correction Factor for Industrial Service (Far) & Power transmitted by belt (Pt) and hit the calculate button. Here is how the Design Power for V Belt calculation can be explained with given input values -> 0.008385 = 1.3*6450.

FAQ

What is Design Power for V Belt?
Design Power for V Belt formula is defined as the power produced or transmitted by a device on basis of its design of construction and is represented as Pd = Far*Pt or Design Power of Belt Drive = Correction Factor for Industrial Service*Power transmitted by belt. Correction Factor for Industrial Service is the correction factor that is used for industrial purpose & Power transmitted by belt is the amount of power that is transmitted from the belt of a belt drive to the pulley.
How to calculate Design Power for V Belt?
Design Power for V Belt formula is defined as the power produced or transmitted by a device on basis of its design of construction is calculated using Design Power of Belt Drive = Correction Factor for Industrial Service*Power transmitted by belt. To calculate Design Power for V Belt, you need Correction Factor for Industrial Service (Far) & Power transmitted by belt (Pt). With our tool, you need to enter the respective value for Correction Factor for Industrial Service & Power transmitted by belt and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.