Normalized Output Voltage of Single Phase Full Converter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Normalized Output Voltage Full Converter = cos(Firing Angle Full Converter)
Vn(full) = cos(αfull)
This formula uses 1 Functions, 2 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Normalized Output Voltage Full Converter - Normalized Output Voltage Full Converter is found be normalizing the average output voltage with maximum voltage in a full converter based circuit.
Firing Angle Full Converter - (Measured in Radian) - Firing Angle Full Converter refers to the point within each AC voltage cycle at which the thyristors are triggered to conduct current in a full converter.
STEP 1: Convert Input(s) to Base Unit
Firing Angle Full Converter: 35 Degree --> 0.610865238197901 Radian (Check conversion here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vn(full) = cos(αfull) --> cos(0.610865238197901)
Evaluating ... ...
Vn(full) = 0.819152044289057
STEP 3: Convert Result to Output's Unit
0.819152044289057 --> No Conversion Required
FINAL ANSWER
0.819152044289057 0.819152 <-- Normalized Output Voltage Full Converter
(Calculation completed in 00.004 seconds)

Credits

Created by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has created this Calculator and 50+ more calculators!
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

10+ Single Phase Full Converter Calculators

Fundamental Component of Source Current for Constant Load Current
Go Fundamental Current Component Full Converter = Load Current Full converter/(sqrt(2)*cos(Power Factor Full Converter))
Real Power for Constant Load Current
Go Real Power Full Converter = Load Voltage Full Converter*Load Current Full converter*cos(Firing Angle Full Converter)
Average DC Output Voltage of Single Phase Full Converter
Go Average Voltage Full Converter = (2*Maximum DC Output Voltage Full Converter*cos(Firing Angle Full Converter))/pi
Apparent Power using RMS Value
Go Apparent Power Full Converter = (Load Current Full converter*Maximum DC Output Voltage Full Converter)/2
Maximum Output DC Voltage of Single Phase Full Converter
Go Maximum DC Output Voltage Full Converter = (2*Maximum Input Voltage Full Converter)/pi
Apparent Power for Constant Load Current
Go Apparent Power Full Converter = Load Current Full converter*Load Voltage Full Converter
RMS Output Voltage of Single Phase Full Converter
Go RMS Output Voltage Full Converter = Maximum Input Voltage Full Converter/(sqrt(2))
Normalized Output Voltage of Single Phase Full Converter
Go Normalized Output Voltage Full Converter = cos(Firing Angle Full Converter)
Total Power Factor for Continuous Load Current
Go Power Factor Full Converter = cos(Firing Angle Full Converter)
RMS Magnitude of Fundamental Source Current for Constant Load Current
Go RMS Fundamental Current Component Full Converter = 0.707*Load Current Full converter

Normalized Output Voltage of Single Phase Full Converter Formula

Normalized Output Voltage Full Converter = cos(Firing Angle Full Converter)
Vn(full) = cos(αfull)

What is the physical significance of power factor?

The significance of power factor lies in the fact that utility companies supply customers with volt-amperes, but bill them for watts. Power factors below 1.0 require a utility to generate more than the minimum volt-amperes necessary to supply the real power (watts).

How to Calculate Normalized Output Voltage of Single Phase Full Converter?

Normalized Output Voltage of Single Phase Full Converter calculator uses Normalized Output Voltage Full Converter = cos(Firing Angle Full Converter) to calculate the Normalized Output Voltage Full Converter, Normalized Output Voltage of Single Phase Full Converter formula is defined as the power factor due to the phase shift between voltage and current at the fundamental line frequency. Normalized Output Voltage Full Converter is denoted by Vn(full) symbol.

How to calculate Normalized Output Voltage of Single Phase Full Converter using this online calculator? To use this online calculator for Normalized Output Voltage of Single Phase Full Converter, enter Firing Angle Full Converter full) and hit the calculate button. Here is how the Normalized Output Voltage of Single Phase Full Converter calculation can be explained with given input values -> 0.819152 = cos(0.610865238197901).

FAQ

What is Normalized Output Voltage of Single Phase Full Converter?
Normalized Output Voltage of Single Phase Full Converter formula is defined as the power factor due to the phase shift between voltage and current at the fundamental line frequency and is represented as Vn(full) = cos(αfull) or Normalized Output Voltage Full Converter = cos(Firing Angle Full Converter). Firing Angle Full Converter refers to the point within each AC voltage cycle at which the thyristors are triggered to conduct current in a full converter.
How to calculate Normalized Output Voltage of Single Phase Full Converter?
Normalized Output Voltage of Single Phase Full Converter formula is defined as the power factor due to the phase shift between voltage and current at the fundamental line frequency is calculated using Normalized Output Voltage Full Converter = cos(Firing Angle Full Converter). To calculate Normalized Output Voltage of Single Phase Full Converter, you need Firing Angle Full Converter full). With our tool, you need to enter the respective value for Firing Angle Full Converter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!