Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid Solution

STEP 0: Pre-Calculation Summary
Formula Used
Effectiveness of HE When Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid))
εc = (modulus((Tci-Tco))/(Thi-Tco))
This formula uses 1 Functions, 4 Variables
Functions Used
modulus - Modulus of number, modulus
Variables Used
Effectiveness of HE When Cold Fluid is Min Fluid - Effectiveness of HE When Cold Fluid is Min Fluid means specific heat is minimum for cold fluid. HE= Heat Exchanger. , Min= Minimum.
Inlet Temperature of Cold Fluid - (Measured in Kelvin) - Inlet Temperature of Cold Fluid is the temperature at which the cold fluid enters the heat exchanger.
Outlet Temperature of Cold Fluid - (Measured in Kelvin) - Outlet Temperature of Cold Fluid is the temperature at which the cold fluid exits the heat exchanger.
Inlet Temperature of Hot Fluid - (Measured in Kelvin) - Inlet Temperature of Hot Fluid is the temperature at which the hot fluid enters the heat exchanger.
STEP 1: Convert Input(s) to Base Unit
Inlet Temperature of Cold Fluid: 5 Kelvin --> 5 Kelvin No Conversion Required
Outlet Temperature of Cold Fluid: 10 Kelvin --> 10 Kelvin No Conversion Required
Inlet Temperature of Hot Fluid: 35 Kelvin --> 35 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
εc = (modulus((Tci-Tco))/(Thi-Tco)) --> (modulus((5-10))/(35-10))
Evaluating ... ...
εc = 0.2
STEP 3: Convert Result to Output's Unit
0.2 --> No Conversion Required
FINAL ANSWER
0.2 <-- Effectiveness of HE When Cold Fluid is Min Fluid
(Calculation completed in 00.047 seconds)

Credits

Created by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has created this Calculator and 50+ more calculators!
Verified by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has verified this Calculator and 300+ more calculators!

10+ Heat Exchanger Calculators

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid
Effectiveness of HE When Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)) Go
Thermal Resistance for Conduction at Tube Wall
Thermal Resistance = (ln(Outer Radius of Cylinder/Inner Radius of Cylinder))/(2*pi*Thermal Conductivity*Length of Cylinder) Go
Effectiveness of Parallel-Flow Heat Exchanger if Cold Fluid is Minimum Fluid
Effectiveness of HE When Cold Fluid is Min Fluid = (Outlet Temperature of Cold Fluid-Inlet Temperature of Cold Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid) Go
Effectiveness of Parallel-Flow Heat Exchanger if Hot Fluid is Minimum Fluid
Effectiveness of HE When Hot Fluid is Min Fluid = ((Inlet Temperature of Hot Fluid-Outlet Temperature of Hot Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid)) Go
Effectiveness of Counter-Current Heat Exchanger if Hot Fluid is Minimum Fluid
Effectiveness of HE When Hot Fluid is Min Fluid = (Inlet Temperature of Hot Fluid-Outlet Temperature of Hot Fluid)/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid) Go
Maximum Possible Rate of Heat Transfer
Maximum Possible Rate of Heat Transfer = Minimum Capacity Rate*(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid) Go
Heat Exchanger Effectiveness for Minimum Fluid
Effectiveness of Heat Exchanger = Temperature Difference of Minimum Fluid/Maximum Temperature Difference in Heat Exchanger Go
Heat Exchanger Effectiveness
Effectiveness of Heat Exchanger = Actual Rate of Heat Transfer/Maximum Possible Rate of Heat Transfer Go
Thermal Resistance for Convection at the Outer Surface
Thermal Resistance = 1/(External Convection Heat Transfer Coefficient*Outside Area) Go
Thermal Resistance for Convection at the Inner Surface
Thermal Resistance = 1/(Inside Area*Inside Convection Heat Transfer Coefficient) Go

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid Formula

Effectiveness of HE When Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid))
εc = (modulus((Tci-Tco))/(Thi-Tco))

What is Heat Exchanger?

A Heat Exchanger is a device that facilitates the process of heat exchange between two fluids that are at different temperatures.

What are the different types of Heat Exchanger?

Mainly Heat Exchanger are divided in 4 categories: Hairpin Type Heat Exchanger, Double Pipe Heat Exchanger, Shell and Tube Heat Exchanger & Plate Type Heat Exchanger.

How to Calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?

Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid calculator uses Effectiveness of HE When Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)) to calculate the Effectiveness of HE When Cold Fluid is Min Fluid, The Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid formula is defined as the ratio of temperature difference of inlet and outlet of cold fluid to the inlet of hot and outlet of cold fluid. Multiplication with -1 is necessity because effectiveness cannot be negative. Effectiveness of HE When Cold Fluid is Min Fluid is denoted by εc symbol.

How to calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid using this online calculator? To use this online calculator for Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid, enter Inlet Temperature of Cold Fluid (Tci), Outlet Temperature of Cold Fluid (Tco) & Inlet Temperature of Hot Fluid (Thi) and hit the calculate button. Here is how the Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid calculation can be explained with given input values -> 0.2 = (modulus((5-10))/(35-10)).

FAQ

What is Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?
The Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid formula is defined as the ratio of temperature difference of inlet and outlet of cold fluid to the inlet of hot and outlet of cold fluid. Multiplication with -1 is necessity because effectiveness cannot be negative and is represented as εc = (modulus((Tci-Tco))/(Thi-Tco)) or Effectiveness of HE When Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)). Inlet Temperature of Cold Fluid is the temperature at which the cold fluid enters the heat exchanger, Outlet Temperature of Cold Fluid is the temperature at which the cold fluid exits the heat exchanger & Inlet Temperature of Hot Fluid is the temperature at which the hot fluid enters the heat exchanger.
How to calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid?
The Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid formula is defined as the ratio of temperature difference of inlet and outlet of cold fluid to the inlet of hot and outlet of cold fluid. Multiplication with -1 is necessity because effectiveness cannot be negative is calculated using Effectiveness of HE When Cold Fluid is Min Fluid = (modulus((Inlet Temperature of Cold Fluid-Outlet Temperature of Cold Fluid))/(Inlet Temperature of Hot Fluid-Outlet Temperature of Cold Fluid)). To calculate Effectiveness of Counter-Current Heat Exchanger if Cold Fluid is Minimum Fluid, you need Inlet Temperature of Cold Fluid (Tci), Outlet Temperature of Cold Fluid (Tco) & Inlet Temperature of Hot Fluid (Thi). With our tool, you need to enter the respective value for Inlet Temperature of Cold Fluid, Outlet Temperature of Cold Fluid & Inlet Temperature of Hot Fluid and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Effectiveness of HE When Cold Fluid is Min Fluid?
In this formula, Effectiveness of HE When Cold Fluid is Min Fluid uses Inlet Temperature of Cold Fluid, Outlet Temperature of Cold Fluid & Inlet Temperature of Hot Fluid. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Effectiveness of HE When Cold Fluid is Min Fluid = (Outlet Temperature of Cold Fluid-Inlet Temperature of Cold Fluid)/(Inlet Temperature of Hot Fluid-Inlet Temperature of Cold Fluid)