Equation for Well Parameter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period)
u = (r^2*S)/(4*T*t)
This formula uses 5 Variables
Variables Used
Well Parameter - Well Parameter for the unsteady flow in confined aquifer. Confined aquifers are permeable rock units that are usually deeper under the ground than unconfined aquifers.
Distance from Pumping Well - (Measured in Meter) - Distance from Pumping Well to the point where drawdown occurs.
Storage Coefficient - Storage Coefficient is the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer.
Transmissivity - (Measured in Square Meter per Second) - Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it.
Time Period - (Measured in Second) - Time Period (pumping has been in Progress) or Time can be defined as the ongoing and continuous sequence of events that occur in succession, from the past through the present to the future.
STEP 1: Convert Input(s) to Base Unit
Distance from Pumping Well: 3 Meter --> 3 Meter No Conversion Required
Storage Coefficient: 85 --> No Conversion Required
Transmissivity: 11 Square Meter per Second --> 11 Square Meter per Second No Conversion Required
Time Period: 30 Second --> 30 Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
u = (r^2*S)/(4*T*t) --> (3^2*85)/(4*11*30)
Evaluating ... ...
u = 0.579545454545455
STEP 3: Convert Result to Output's Unit
0.579545454545455 --> No Conversion Required
FINAL ANSWER
0.579545454545455 0.579545 <-- Well Parameter
(Calculation completed in 00.004 seconds)

Credits

Created by Mithila Muthamma PA
Coorg Institute of Technology (CIT), Coorg
Mithila Muthamma PA has created this Calculator and 2000+ more calculators!
Verified by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has verified this Calculator and 1700+ more calculators!

11 Unsteady Flow in a Confined Aquifer Calculators

Equation for Drawdown
Go Total Drawdown = (Discharge/(4*pi*Transmissivity))*ln((2.2*Transmissivity*Time Period)/(Distance from Pumping Well^2*Storage Coefficient))
Drawdown at Time Interval 't1'
Go Drawdown at time interval t1 = Drawdown at time interval t2-((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))
Drawdown at Time Interval 't2'
Go Drawdown at time interval t2 = ((Discharge/(4*pi*Transmissivity))*ln(Time of Drawdown (t2)/Time of Drawdown (t1)))+Drawdown at time interval t1
Equation for Well Function series to number of 4 digits
Go Well Function of u = -0.577216-ln(Well Parameter)+Well Parameter-(Well Parameter^2/2.2!)+(Well Parameter^3/3.3!)
Equation for Well Parameter
Go Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period)
Distance from Pumping Well given Storage Coefficient
Go Distance from Pumping Well = sqrt((2.25*Transmissivity*Starting Time/Storage Coefficient))
Initial Time given Pumping Well along with Storage Coefficient
Go Starting Time = (Storage Coefficient*Distance from Pumping Well^2)/(2.25*Transmissivity)
Transmissivity about given storage coefficient
Go Transmissivity = (Storage Coefficient*Distance from Pumping Well^2)/(2.25*Starting Time)
Equation for Storage Coefficient
Go Storage Coefficient = 2.25*Transmissivity*Starting Time/Distance from Pumping Well^2
Initial Constant Piezometric Head given drawdown
Go Initial constant Piezometric Head = Possible Drawdown in Confined Aquifer+Drawdown at time t
Drawdown given Piezometric Head
Go Possible Drawdown in Confined Aquifer = Initial constant Piezometric Head-Drawdown at time t

Equation for Well Parameter Formula

Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period)
u = (r^2*S)/(4*T*t)

What is Drawdown in Hydrology?

Drawdown is a change in groundwater level due to an applied stress, caused by events such as: Pumping from a well. Pumping from a neighboring well. Intensive water taking from local area. Seasonal declines as recharge rates lower.

How to Calculate Equation for Well Parameter?

Equation for Well Parameter calculator uses Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period) to calculate the Well Parameter, Equation for Well Parameter is an essential property of the well function represented by a number if series to significant digits, rarely exceeding 4. Well Parameter is denoted by u symbol.

How to calculate Equation for Well Parameter using this online calculator? To use this online calculator for Equation for Well Parameter, enter Distance from Pumping Well (r), Storage Coefficient (S), Transmissivity (T) & Time Period (t) and hit the calculate button. Here is how the Equation for Well Parameter calculation can be explained with given input values -> 0.579545 = (3^2*85)/(4*11*30).

FAQ

What is Equation for Well Parameter?
Equation for Well Parameter is an essential property of the well function represented by a number if series to significant digits, rarely exceeding 4 and is represented as u = (r^2*S)/(4*T*t) or Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period). Distance from Pumping Well to the point where drawdown occurs, Storage Coefficient is the volume of water released from storage per unit decline in hydraulic head in the aquifer, per unit area of the aquifer, Transmissivity is the rate at which groundwater flows horizontally through an aquifer or the degree to which a medium allows something, in particular electromagnetic radiation, to pass through it & Time Period (pumping has been in Progress) or Time can be defined as the ongoing and continuous sequence of events that occur in succession, from the past through the present to the future.
How to calculate Equation for Well Parameter?
Equation for Well Parameter is an essential property of the well function represented by a number if series to significant digits, rarely exceeding 4 is calculated using Well Parameter = (Distance from Pumping Well^2*Storage Coefficient)/(4*Transmissivity*Time Period). To calculate Equation for Well Parameter, you need Distance from Pumping Well (r), Storage Coefficient (S), Transmissivity (T) & Time Period (t). With our tool, you need to enter the respective value for Distance from Pumping Well, Storage Coefficient, Transmissivity & Time Period and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!