Equipment Utilization Factor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Equipment Utilization Factor = SE when SC Fully Utilized/Total Number of SE
EUF = S/TSE
This formula uses 3 Variables
Variables Used
Equipment Utilization Factor - The equipment utilization factor refers to the measure of how effectively the equipment or resources within the system are utilized over a given period of time.
SE when SC Fully Utilized - SE when SC fully utilized refers to the number of switching elements (SEs) required in a telecommunication switch or system when the switching capacity (SC) is fully utilized.
Total Number of SE - Total number of SE refers to the total count of switching elements present in the system and are the components responsible for connecting, routing, and managing the flow of calls or data.
STEP 1: Convert Input(s) to Base Unit
SE when SC Fully Utilized: 42 --> No Conversion Required
Total Number of SE: 7 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
EUF = S/TSE --> 42/7
Evaluating ... ...
EUF = 6
STEP 3: Convert Result to Output's Unit
6 --> No Conversion Required
FINAL ANSWER
6 <-- Equipment Utilization Factor
(Calculation completed in 00.004 seconds)

Credits

Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

15 Digital Switching System Calculators

Maximum Variation Resistance by Carbon Granules
Go Maximum Variation in Resistance = (Quiescent Resistance-Instantaneous Resistance)/sin(Angular Frequency*Time Period)
Quiescent Resistance of Microphone
Go Quiescent Resistance = Instantaneous Resistance+Maximum Variation in Resistance*sin(Angular Frequency*Time Period)
Instantaneous Resistance of Microphone
Go Instantaneous Resistance = Quiescent Resistance-Maximum Variation in Resistance*sin(Angular Frequency*Time Period)
Number of Switching Elements
Go Number of Switching Element = (Cost of Switching System-Cost of Common Hardware-Cost of Common Control System)/Cost per Switching Element
Average Switching Time per Stage
Go Average Switching Time per Stage = (Call Setup Time-Time Required Other than Switching)/Number of Switching Stage
Number of Switching Stage
Go Number of Switching Stage = (Call Setup Time-Time Required Other than Switching)/Average Switching Time per Stage
Switching Element Advantage Factor
Go Switching Element Advantage Factor = Number of SE in Single Switch/Number of SE in Equivalent Multistage
Number of SE in Equivalent Multistage
Go Number of SE in Equivalent Multistage = Number of SE in Single Switch/Switching Element Advantage Factor
Number of SE in Single Switch
Go Number of SE in Single Switch = Number of SE in Equivalent Multistage*Switching Element Advantage Factor
Theoretical Maximum Load
Go Number of Subscriber Lines = (2*Switching Capacity)/Traffic Handling Capacity
Number of SE when SC Fully Utilised
Go SE when SC Fully Utilized = Total Number of SE*Equipment Utilization Factor
Total Number of SE in System
Go Total Number of SE = SE when SC Fully Utilized/Equipment Utilization Factor
Equipment Utilization Factor
Go Equipment Utilization Factor = SE when SC Fully Utilized/Total Number of SE
Power Ratio
Go Power Ratio = 20*log10(Voltage2/Voltage1)
Sinusoidal Input
Go Sinusoidal Input = Quantization Error*2*Voltage

Equipment Utilization Factor Formula

Equipment Utilization Factor = SE when SC Fully Utilized/Total Number of SE
EUF = S/TSE

What is utilization factor?

In electrical engineering, utilization factor, is the ratio of the maximum load which could be drawn to the rated capacity of the system. This is closely related to the concept of Load factor. The Load factor is the ratio of the load that a piece of equipment actually draws (time averaged) when it is in operation to the load it could draw.

How to Calculate Equipment Utilization Factor?

Equipment Utilization Factor calculator uses Equipment Utilization Factor = SE when SC Fully Utilized/Total Number of SE to calculate the Equipment Utilization Factor, The Equipment Utilization Factor formula is defined as the utilization factor or use factor is the ratio of the time that a piece of equipment is in use to the total time that it could be in use. It is often averaged over time in the definition such that the ratio becomes the amount of energy used divided by the maximum possible to be used. Equipment Utilization Factor is denoted by EUF symbol.

How to calculate Equipment Utilization Factor using this online calculator? To use this online calculator for Equipment Utilization Factor, enter SE when SC Fully Utilized (S) & Total Number of SE (TSE) and hit the calculate button. Here is how the Equipment Utilization Factor calculation can be explained with given input values -> 6 = 42/7.

FAQ

What is Equipment Utilization Factor?
The Equipment Utilization Factor formula is defined as the utilization factor or use factor is the ratio of the time that a piece of equipment is in use to the total time that it could be in use. It is often averaged over time in the definition such that the ratio becomes the amount of energy used divided by the maximum possible to be used and is represented as EUF = S/TSE or Equipment Utilization Factor = SE when SC Fully Utilized/Total Number of SE. SE when SC fully utilized refers to the number of switching elements (SEs) required in a telecommunication switch or system when the switching capacity (SC) is fully utilized & Total number of SE refers to the total count of switching elements present in the system and are the components responsible for connecting, routing, and managing the flow of calls or data.
How to calculate Equipment Utilization Factor?
The Equipment Utilization Factor formula is defined as the utilization factor or use factor is the ratio of the time that a piece of equipment is in use to the total time that it could be in use. It is often averaged over time in the definition such that the ratio becomes the amount of energy used divided by the maximum possible to be used is calculated using Equipment Utilization Factor = SE when SC Fully Utilized/Total Number of SE. To calculate Equipment Utilization Factor, you need SE when SC Fully Utilized (S) & Total Number of SE (TSE). With our tool, you need to enter the respective value for SE when SC Fully Utilized & Total Number of SE and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!